Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 268/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters | ||
Measuring range | Water: 20~100000L/h | Air:0.3~3000Nm /h |
Refer to the flow meter | ||
Range down | 10:1(DN≤100mm) | 5:1 (DN≤100mm) |
Accuracy | Standard Class 1.5 | Special class 1.0 |
Pressure class | (DN15, N25, D40, D50) 0~4.0MPa | |
(DN80, DN100, DN150)0~1.6MPa | ||
Medium temperature | Ordinary: -40ºC~100ºC | High temperature:-80ºC~250ºC |
Lining PTFE:-40ºC~ | ||
Ambient temperature | Pointer type: -40ºC~+65ºC | |
Intelligent type: -25ºC~+65ºC | ||
Connection type | Flange, Thread, Clamping | |
Electrical interface | M20×1.5 special can be customized | |
Protection grade | IP67 | |
Ex-proof class | Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473 | |
Medium viscosity | DN15≤5Mpa.s (DN25~150)≤5Mpa.s | |
Power supply | 3.6V lithium battery, 24VDC | |
Measuring pipe material | 304, 316L, 304 or 316L, PTFE or F46 | |
Float material | 304 or 316L;PTFE or PFA |
Flow sheet | Float material: 1, Cr Ni steel 2, PTFE | ||||
Caliber | Float No. | Flow range H2O | Flow range air | Press loss Kpa | |
1 CrNiSteel | PTFE | 1 CrNiSteel | |||
DN15 | F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 | 10 1/h 15 1/h 20 1/h 25 1/h 30 1/h 35 1/h 40 1/h 45 1/h 50 1/h 55 1/h 60 1/h 70 1/h 80 1/h 90 1/h 100 1/h 120 I /h 160 1/h 200 I /h 220 I /h 250 I /h 280 I /h 300 I /h 350 I /h 400 1/h 450 1/h 500 1/h 600 1/h 700I/h 800 1/h 9001/h 1000 1/h |
25 1/h 30 1/h 35 1/h 40 1/h 45 1/h 50 1/h 55 1/h 60 1/h 70 1/h 80 1/h 90 1/h 100 1/h 120 1/h 160 1/h 200 1/h 220 1/h 250 1/h 280 1/h 300 1/h 350 1/h 400 1/h |
0.30 Nm³/h 0.45 Nm³/h 0.60 Nm³/h 0.75 Nm³/h 0.90 Nm³/h 1.05 Nm³/h 1.20 Nm³/h 1.35 Nm³/h 1.50 Nm³/h 1.65 Nm³/h 1.80 Nm³/h 2.10 Nm³/h 2.40 Nm³/h 2.70 Nm³/h 3.00 Nm³/h 3.60 Nm³/h 4.80 Nm³/h 6.00 Nm³/h 6.60 Nm³/h 7.50 Nm³/h 8.40 Nm³/h 9.00 Nm³/h 10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³ |
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5 3.5 3.5 3.5 |
D25 |
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7 F25.8 F25.9 F25.10 F25.11 |
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h | 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h | 30.0 Nm³/h 36.0 Nm³/h 48.0 Nm³/h 60.0 Nm³/h 75.0 Nm³/h 90.0Nm³/h 105.0 Nm³/h 120.0 Nm³/h 135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³ |
1.5 1.5 3.0 3.0 3.5 3.5 8.0 8.0 8.0 16.0 16.0 16.0 |
D50 |
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 | 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h | 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h | 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h | 3.0 3.0 4.0 4.0 4.0 8.0 8.0 16.0 16.0 |
D65 |
F65.0 F65.1 F65.2 F65.3 F65.4 | 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h | 12000l/h 16000l/h 20000l/h | 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/ | |
D80 |
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 | 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h | 25000 I /h 30000 I /h 35000 I /h 40000 I /h | 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h | 14.0 14.0 14.0 22.0 22.0 25.0 25.0 |
D100 |
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 | 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h | 50000l/h 60000 l/h | 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h | 30.0 30.0 30.0 30.0 40.0 40.0 |
D125 |
F125.0 F125.1 F125.2 | 100000 l/h 125000 l/h 150000 l/h | 100000 l/h 125000 l/h | 3000.0Nm³/h 3800.00 Nm³/h | 45.0 45.0 48.0 |
Product selection | |||||||||||
ZYZZ A B C D E F | |||||||||||
Model structure wetting material additional structure caliber medium indicator | |||||||||||
ZYZZ | Metal pipe floating flowmeter | ||||||||||
Standard is A |
Measuring pipe structure, A | ||||||||||
A | Down in, up out | ||||||||||
B | Up in, down out | ||||||||||
C | Side in, side out | ||||||||||
D | Bottom in, side out | ||||||||||
E | Right in, left out | ||||||||||
F | Left in, right out | ||||||||||
G | Clamp | ||||||||||
H | Thread connection | ||||||||||
Standard is R1 |
Wetting material B | Special consult with factory | |||||||||
R1 | 1Cr18Ni9Ti,304 | ||||||||||
RO | 0cr18Ni12M02Ti,316 | ||||||||||
RL | 316L | ||||||||||
RP | PTFE | ||||||||||
Ni | HC 276 | ||||||||||
Ti | Titanium | ||||||||||
Standard is N |
Additonal structure C | ||||||||||
N | No | ||||||||||
Z | Damping | ||||||||||
J | Clamping | ||||||||||
G | High temperature | ||||||||||
L | High pressure | ||||||||||
Caliber | DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200 | ||||||||||
Medium |
Medium type E | ||||||||||
L | Liquid | ||||||||||
G | Gas | ||||||||||
Standard is 5 |
M1 | ||||||||||
M2 | |||||||||||
M3 | |||||||||||
M4 | |||||||||||
M5 | |||||||||||
Power supply mode | |||||||||||
Default A | J | Local indication no power supply | |||||||||
A | 24V DC Two wire power supply 4-20 mA output | ||||||||||
B | Battery, field LCD display,no signal output | ||||||||||
C | 100VAC-240VAC 50HZ-60HZ,output 4-20mA | ||||||||||
Default L |
Display | ||||||||||
L | With LCD | ||||||||||
X | Without LCD | ||||||||||
Defult N |
Alarm selection | ||||||||||
N | No alarm | ||||||||||
K1 | Upper limit alarm | ||||||||||
K2 | Lower limit alarm | ||||||||||
K3 | UP and lower limit alarm | ||||||||||
Default D |
Ex-proof sign | ||||||||||
N | No | ||||||||||
D | Flame-proof ExdIICT6 | ||||||||||
I | Intrinsic safety EX(ia)IICT6 | ||||||||||
Default N |
N | No communication protocol | |||||||||
H | Hart protocol | ||||||||||
M | Modbus protocol | ||||||||||
P | PROfibus-PA field bus | ||||||||||
Model selection example:ZYZZ/A/R1/M5/DN25 | |||||||||||
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we pledge to deliver your Good Repeatability Flowmeter with High Accuracy and Threaded Mounting Options promptly, precisely tailored to your specifications. Our commitment ensures that you receive top-notch service, with a focus on timely and efficient delivery to meet your needs.Installation:
The metal rotor flowmeter is a variable area flow measuring instrument based on the measurement of the float position.
It features an all-metal structure and a modular design concept. Due to its small size, low pressure loss, large range ratio (10:1),
and ease of installation and maintenance, it is widely used in various industries under complex and harsh environments
for flow and process control of small flow rates, low velocities, and various demanding medium conditions.
Proper installation of the metal rotor flowmeter is particularly important for its normal operation. Installation considerations:
(1) The flowmeter must be installed vertically, with the measured fluid flowing from bottom to top through the flowmeter. There should be a straight pipe section of five times the instrument diameter at both the inlet and outlet. For newly installed pipelines, the pipeline should be thoroughly flushed before installing the flowmeter.
(2) A valve should be installed upstream of the flowmeter, and a flow control valve should be installed 5 to 10 times the instrument diameter downstream. For small diameter instruments, a filter should be installed upstream. If the measured medium contains magnetic materials, a magnetic filter should be installed before the flowmeter.
(3) To facilitate maintenance and replacement of the flowmeter, a bypass pipeline should be connected during the installation of the instrument.
(4) When the measured medium is relatively dirty, the pipes and float should be cleaned in a timely manner.
(5) The measurement accuracy of the metal rotor flowmeter is generally at a level of 1.5. If higher measurement accuracy is required, it is not advisable to choose a metal tube rotor flowmeter.
Company and factory photos