Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
  • Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter, an epitome of precision and reliability, consists of two primary components: a sensor and a converter. Operating under Faraday's electromagnetic induction law, this advanced device is designed to measure conductive fluids with utmost accuracy. Distinguished by its cutting-edge excitation, lining, and intelligent technologies, the ZYDC flow meter stands at the forefront of the industry, aligning with standards such as JB/T9248-2015 and JJG 1033-2007. Continuous enhancements ensure this flow meter remains a leader in performance and efficiency.

Features:

- Exhibits stable performance with exceptional repeatability and high accuracy, reaching up to 0.2%.
- Designed with no flow obstruction components, ensuring zero pressure loss and resistance to clogging.
- Exceptionally adaptable to highly corrosive and abrasive media, ensuring longevity and reliability.
- Facilitates operation without cover removal via mobile Bluetooth and infrared remote control.
- Incorporates stainless steel mesh technology, making it ideal for applications under negative pressure.
- Supports GPRS and Bluetooth wireless transmission, and is compatible with communication protocols such as MODBUS and HART.
- Powered by a 16-bit embedded microprocessor, offering rapid computation, high precision, and programmable low-frequency square wave excitation for enhanced measurement stability with low power consumption.
- Utilizes SMD components and surface mount technology (SMT), ensuring high circuit reliability. Measurement range can be modified online to match user-specific data acquisition needs.
- Delivers measurement outcomes that are independent of fluid pressure, temperature, density, viscosity, and other physical parameters.
- Features digital communication signal outputs, including RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Equipped with self-check, self-diagnosis, and alarm functionalities for enhanced operational safety.
- Contains three internal accumulators to separately display forward, reverse, and differential cumulative amounts. An internal clock is available to record up to 16 power outage events (optional).
- The ultra-low EMI switch power supply is designed for wide power supply voltage variations with excellent EMI resistance.
Detailed Photos
 
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Product Parameters
 
Technical Parameters: Elevate your measurement capabilities with our Good Repeatability Flowmeter. Featuring state-of-the-art wireless transmission technology and precision-engineered to meet the highest accuracy standards, this flowmeter is designed for seamless integration into your existing systems. Experience unparalleled reliability and efficiency with our cutting-edge solution for all your flow measurement needs.
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards

PACKING & SHIPPING

We are committed to delivering your ordered product at the earliest possible date, tailored to your specific requirements, ensuring a seamless and efficient service experience for you.
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Installation Instructions
 

The installation of the electromagnetic flowmeter from Shandong Zhongziyi Intelligent Technology Co., Ltd. is contingent upon site-specific pipeline conditions. Flowmeters that do not feature a ball valve should be installed on non-pressurized pipelines. This non-pressurized installation approach allows for the selection of flowmeters sans ball valves, enhancing operational flexibility.
Prepare to craft a hole with a diameter of 50mm in the pipeline. Subsequent to this, arrangements should be made to weld a connecting pipe to this newly created opening, ensuring a seamless integration.
For scenarios necessitating uninterrupted flow during both loading and unloading phases or where media overflow is strictly prohibited, it is imperative to integrate a ball valve. This calls for the selection of an insertion-type electromagnetic flowmeter equipped with a ball valve structure, assuring optimal performance.
A hole with a diameter of 50mm should be meticulously crafted in the pipeline. Subsequent preparations should be made to weld a connecting pipe to this opening, ensuring robust and reliable performance.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

To guarantee precise and accurate measurements, the upstream and downstream sections of the pipeline must adhere to specific standards: 5D upstream and 3D downstream. This ensures the electromagnetic flowmeter operates within its accuracy parameters.

The measurement principle of the electromagnetic flowmeter remains unaffected by the inherent characteristics of the flow, showcasing its advanced and resilient design.
If turbulence and vortices emerge in the non-measurement areas of the pipeline-caused by elements like elbows, tangential throttling, or partially open shut-off valves upstream-they will not compromise measurement accuracy.

However, the presence of steady-state vortices within the measurement area can destabilize and skew measurement accuracy, necessitating corrective measures.
In such instances, it is essential to implement strategies to stabilize the flow distribution effectively:

  1. 1. Increase the length of the straight pipe sections both upstream and downstream.
  2. 2. Utilize a flow stabilizer to mitigate flow disruptions.
  3. 3. Reduce the cross-section of the measurement point to refine flow dynamics.
  1. Requirements for the External Environment
    1. To maintain optimal performance, the flowmeter should be shielded from significant temperature fluctuations and high-temperature radiation. If installation in such areas is unavoidable, ensure appropriate insulation and ventilation measures are in place.
    2. For best results, install the flowmeter indoors. If outdoor installation is necessary, protect it from rain, flooding, and direct sunlight by incorporating moisture-proof and sun-proof measures.
    3. Avoid installing the flowmeter in environments containing corrosive gases. If this is unavoidable, implement efficient ventilation measures to safeguard the device.
    4. Ensure there is ample space around the flowmeter to facilitate easy installation, maintenance, and upkeep, thereby extending its operational lifespan.
    5. The installation site should be free from magnetic fields and strong vibration sources. If significant pipeline vibration is present, provide supports on both sides of the flowmeter to stabilize the pipeline and ensure accurate readings.

1.2. Pipeline-type Electromagnetic Flowmeter

2.1. Requirements for Straight Sections To counteract vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are mandated. Failure to meet these requirements can affect measurement accuracy. Installing a straightener and avoiding proximity to control and partially open valves is also advisable.

2.2. Requirements for Process Pipes The flowmeter's installation point mandates specific upstream and downstream process pipe conditions to ensure measurement accuracy. a. The inner diameter of these pipes should align with the sensor's diameter: 0.98DN ≤ D ≤ 1.05DN (DN = sensor's inner diameter, D = process pipe's inner diameter). b. The process pipe and sensor should be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes To ensure seamless maintenance and optimal performance of the flowmeter, it is highly recommended to install a bypass pipe. For applications involving heavily contaminated fluids or instances where the flowmeter requires cleaning without interrupting flow, a bypass pipe becomes essential. a. Facilitates easy maintenance of the flowmeter. b. Mandatory for processing heavily contaminated fluids. c. Enables cleaning of the flowmeter without halting fluid flow.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters

3.1. Requirements for Straight Pipe Sections Inlet/Outlet straight pipe sections are critical for accurate and reliable measurements. The inlet section should be at least 10 times the diameter (≥ 10×DN), and the outlet section should be at least 5 times the diameter (≥ 5×DN).

3.2. Requirements for Grounding Points To ensure the instrument's reliable operation and enhance measurement accuracy, it must remain unaffected by external parasitic potentials. Proper grounding of the sensor is crucial, with grounding resistance maintained below 10 ohms. (If the metal pipeline is adequately grounded, a dedicated grounding device is unnecessary.)

3.3. Requirements for Installation Position as Shown in the Diagram


COMPANY AND FACTORY PICTURE:

Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Our Advantages
 
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards


Fostering Team Unity: Building Exceptional Teams

Our Philosophy: Victory Belongs to the Best Team!
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
Showcase: Captivating Exhibition Pictures

Expanding Horizons: Pursuing Global Partnerships Through International Exhibitions
Good Repeatability Flowmeter with Wireless Transmission and High Accuracy Standards
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now