Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service.The installation of the IP67 Electromagnetic Flowmeter with High Accuracy and Anti-Vibration Design by Shandong Zhongziyi Intelligent Technology Co., Ltd. varies based on site pipeline conditions. For non-pressurized pipelines, flowmeters without a ball valve can be selected and installed.
Make a hole with a diameter of 50 in the pipeline, and prepare to weld a connecting pipe to the newly created opening.
For scenarios requiring continuous flow during loading and unloading or where media overflow is not permissible, a ball valve must be incorporated. Select an insertion-type electromagnetic flowmeter with a ball valve structure for these conditions.
Similar to non-pressurized installations, make a hole with a diameter of 50 in the pipeline and get ready to weld a connecting pipe to the opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
Ensure the pipeline has straight pipe sections of 5D upstream and 3D downstream from the flowmeter. This arrangement guarantees the proper function of the electromagnetic flowmeter and meets accuracy standards.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics.
Even if turbulence and vortices are generated in the non-measurement area of the pipeline (such as elbows, throttling, or partially open shut-off valves upstream), these will not affect the measurement.
However, if steady-state vortices are present in the measurement area, they can compromise the stability and accuracy of the measurements.
In such cases, measures should be taken to stabilize the flow distribution:
1.2. Pipeline-Type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate vortices and flow field distortions, specific lengths for straight pipe sections upstream and downstream of the flowmeter are required to avoid measurement accuracy issues. Installing a straightener is advisable, and avoid placing the flowmeter close to control and partially open valves.
2.2. Requirements for Process Pipes The flowmeter has precise requirements for upstream and downstream process pipes at the installation point to ensure measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter and adhere to: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for bypass pipes To ensure seamless maintenance and optimal performance of the flowmeter, the installation of a bypass pipe is highly recommended. This is particularly crucial for scenarios involving heavily contaminated fluids or when the flowmeter must be cleaned without interrupting the fluid flow. a. To facilitate the smooth maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Ensures continuous operation of fluid flow during flowmeter cleaning.
3. Installation requirements for insertion-type electromagnetic flowmeters To guarantee precision and reliability, the installation of insertion-type electromagnetic flowmeters must adhere to specific requirements.
3.1. Requirements for straight pipe sections Inlet/outlet straight pipe sections: To ensure accurate measurements, the inlet pipe should be at least 10×DN in length, and the outlet pipe should be at least 5×DN in length.
3.2. Requirements for grounding points For reliable instrument operation and enhanced measurement accuracy, grounding is paramount. The sensor must be well-grounded to minimize the influence of external parasitic potentials, with grounding resistance kept below 10 ohms. (If the metal pipeline already has good grounding, a dedicated grounding device is not necessary.)
3.3. Requirements for installation position The optimal installation positions should be followed as indicated in the accompanying diagram to ensure the best performance.
COMPANY AND FACTORY PICTURE: Here, you will find visuals showcasing our state-of-the-art company and manufacturing plants, reflecting our commitment to quality and innovation.