Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to providing you with rapid, reliable delivery of your ordered product. Our team ensures that your goods arrive on time and meet your specifications, offering you a seamless and efficient service experience.The installation of the electromagnetic flowmeter depends on the specific site pipeline conditions. If the flowmeter does not feature a ball valve, it should be installed on a non-pressurized pipeline. Choosing a flowmeter without a ball valve is suitable for such conditions.
A 50mm diameter hole should be created in the pipeline, and preparations made to weld a connecting pipe to this opening.
For conditions that require continuous flow during loading and unloading, or where media overflow is unacceptable, an insertion-type electromagnetic flowmeter with a ball valve structure is essential. This selection ensures the prevention of overflow and maintains a steady flow.
A 50mm diameter hole should be created in the pipeline, and preparations made to weld a connecting pipe to this opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The straight pipe sections must adhere to 5D upstream and 3D downstream requirements. This alignment ensures the appropriate use and accuracy of the electromagnetic flowmeter.
The principle of measurement for the electromagnetic flowmeter is independent of the flow characteristics.
If turbulence and vortices occur in the non-measurement area of the pipeline (such as near elbows, tangential throttling, or partially open shut-off valves upstream), it will not affect the measurement.
However, steady-state vortices within the measurement area will impact the stability and accuracy of the readings.
To stabilize the flow distribution in such cases, consider the following measures:
1.2. Pipeline-Type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate vortices and flow field distortion effects, specific requirements for upstream and downstream straight pipe lengths must be met. Otherwise, measurement accuracy will be compromised. Installing a straightener is also advisable, and avoid setup close to control or partially open valves.
2.2. Requirements for Process Pipes The flowmeter has specific upstream and downstream process pipe requirements at the installation point. Failure to meet these requirements can affect measurement accuracy. a. The inner diameter of the upstream and downstream pipes should match the sensor's inner diameter, adhering to the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. This becomes essential when dealing with heavily contaminated fluids or when the flowmeter needs cleaning without interrupting the fluid flow. a. Facilitates the maintenance of the flowmeter. b. Mandatory for heavily contaminated fluids. c. Allows cleaning of the flowmeter without stopping the fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: The inlet should have a straight pipe length of at least 10 times the diameter (10×DN); the outlet should have a minimum length of 5 times the diameter (5×DN).
3.2. Requirements for Grounding Points To guarantee the reliable operation and high measurement accuracy of the instrument, it must be insulated from external parasitic potentials. The sensor requires excellent grounding, with grounding resistance below 10 ohms. (If the metal pipeline is already well-grounded, a dedicated grounding device is unnecessary.)
3.3. Requirements for Installation Position Please refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: