High Precision Flowmeter with Good Repeatability and Anti-Vibration Features

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
  • High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC Electromagnetic Flow Meter consists of two meticulously engineered components: a sensor and a converter. Utilizing the principles of Faraday's electromagnetic induction law, this advanced instrument is designed to measure conductive fluids with unparalleled precision. The ZYDC Electromagnetic Flow Meter stands as a beacon of high precision and exceptional reliability, reflecting continuous upgrades and refinements. With groundbreaking advancements in excitation technology, lining technology, and intelligent systems, it sets the benchmark in the industry. Fully compliant with stringent standards like JB/T9248-2015 and JJG 1033-2007, this flow meter epitomizes excellence.

Features:

- Exhibits remarkable stability, exceptional repeatability, and outstanding accuracy (up to 0.2%).
- Designed with no flow obstruction components, ensuring no pressure loss and resistance to clogging.
- Highly adaptable to media that are both highly corrosive and abrasive.
- Allows seamless operation without opening the cover, thanks to mobile Bluetooth and infrared remote control.
- Incorporates stainless steel mesh technology, making it ideal for negative pressure environments.
- Supports GPRS and Bluetooth wireless transmission; fully compatible with MODBUS and HART communication protocols.
- Powered by a 16-bit embedded microprocessor, offering swift computation speed, superior precision, and programmable low-frequency square wave excitation, thereby enhancing measurement stability with minimal power consumption.
- Utilizes SMD components and surface mount technology (SMT) for unbeatable circuit reliability. - Allows real-time modification of the measurement range based on specific user requirements, ensuring optimal integration with data acquisition terminals.
- Delivers measurement results unaffected by fluid pressure, temperature, density, viscosity, or other physical parameters.
- Features digital communication signal outputs including RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Equipped with self-check, self-diagnosis, and alarm functionalities.
- Contains three internal accumulators displaying forward, reverse, and differential cumulative amounts. An internal clock records up to 16 power outage events (optional).
- The ultra-low EMI switch power supply accommodates a wide range of voltage variations and exhibits excellent EMI resistance.
Detailed Photos
 
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
Product Parameters
 
Technical Parameters: Delve into the meticulous technical details that underscore the superior performance and innovative design of our High Precision Flowmeter, renowned for its exceptional repeatability and robust anti-vibration features.
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we take pride in our efficient and timely delivery service. Our commitment to excellence ensures that your High Precision Flowmeter with Good Repeatability and Anti-Vibration Features reaches you promptly, meeting all your specific requirements with unparalleled reliability and speed.
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
Installation Instructions
 

The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline (i.e., non-pressurized installation allows for the selection of flowmeters without a ball valve).
A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
For situations that require continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added, which means selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

The requirements for the straight pipe sections are 5D upstream and 3D downstream, which ensures the proper use of the electromagnetic flowmeter and meets the accuracy requirements.

The measurement principle of the electromagnetic flowmeter does not depend on the characteristics of the flow.
If there is a certain amount of turbulence and vortices generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), it will not affect the measurement.

However, if there are steady-state vortices in the measurement area, it will affect the stability and accuracy of the measurement.
In this case, some measures should be taken to stabilize the flow distribution:

  1. Increase the length of the straight pipe sections upstream and downstream.
  2. Use a flow stabilizer.
  3. Reduce the cross-section of the measurement point.
  1. Requirements for the external environment
    1. The flowmeter should avoid installation in areas with significant temperature fluctuations or where it is subjected to high-temperature radiation from equipment. If installation is necessary, insulation and ventilation measures must be taken.
    2. The flowmeter is best installed indoors. If it must be installed outdoors, it should be protected from rain, flooding, and direct sunlight, with moisture-proof and sun-proof measures in place.
    3. The flowmeter should avoid installation in environments containing corrosive gases. If installation is necessary, ventilation measures must be implemented.
    4. To facilitate installation, maintenance, and upkeep, there should be ample installation space around the flowmeter.
    5. The installation site of the flowmeter should avoid magnetic fields and strong vibration sources. If there is significant vibration in the pipeline, supports should be provided on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type electromagnetic flowmeter

2.1. Requirements for straight sections To mitigate the effects of vortices and flow field distortion, there are specific requirements for the lengths of the straight pipe sections upstream and downstream of the flowmeter; otherwise, measurement accuracy will be affected (a straightener can also be installed, and it is advisable to avoid installation close to control valves and partially open valves).

2.2. Requirements for the process pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should be the same as that of the sensor and must meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. This is particularly crucial for systems handling heavily contaminated fluids or scenarios where the flowmeter requires cleaning without halting the fluid flow. a. Facilitates easy maintenance of the flowmeter. b. Essential for fluids carrying heavy contaminants. c. Enables flowmeter cleaning without interrupting fluid flow.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters

3.1. Specifications for Straight Pipe Sections Inlet/Outlet Pipe Sections: Ensure the inlet straight pipe section is at least 10 times the DN (Diameter Nominal). The outlet straight pipe section should be at least 5 times the DN.

3.2. Grounding Point Specifications To guarantee reliable operation and heightened measurement accuracy, the instrument must be insulated from external parasitic potentials. The sensor should be thoroughly grounded, achieving a grounding resistance of less than 10 ohms. (If the metal pipeline is adequately grounded, a separate grounding device is not necessary.)

3.3. Installation Position Requirements As illustrated in the accompanying diagram.


COMPANY AND FACTORY PICTURE:

High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
Our Advantages
 
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features


Building an Elite Team

We firmly believe that a stellar team is the cornerstone of success!
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
Gallery of Our Exhibitions

We are proactively pursuing international partnerships by participating in global exhibitions.
High Precision Flowmeter with Good Repeatability and Anti-Vibration Features
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now