Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 268/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
  • 4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYZZ
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN200
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection Type
Flange, Thread, Clamping
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67
Range Down
10:1
Electrical Interface
M20×1.5 Special Can Be Customized
Power Supply
3.6V Lithium Battery, 24VDC
Float Material
304 or 316 L, PTFE or P.F.a
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 20.00cm
Package Gross Weight
3.000kg

Product Description

Product Description
 
Production Overview

The ZYZZ series metal tube float flowmeter harnesses the sophisticated variable area measurement principle,
perfectly suited for the continuous and accurate measurement of volumetric flow rates of both liquids and gases within closed pipeline systems.
Metal tube float flowmeters are renowned for their robust and reliable structure,
boasting a wide operating temperature range, unmatched high accuracy, and impressive cost-effectiveness,
which makes them the ideal choice for diverse and challenging flow measurement applications.

Features:
Product Features

Enhanced geomagnetic compensation ensures precision in various environments.
A diverse and rich variety of indicator forms to suit different needs.
Powerful software capabilities that provide advanced performance.
Dual indication system for comprehensive display information.
Advanced self-damping indicators for stable and accurate readings.
Unique measuring tube and magnetic coupling structure for optimal functionality.
Scientific lead interface designed for seamless connections.
Superior anti-interference performance for reliable operation.
Conveniently connected opto-isolated output for enhanced data transmission.
A complete range of versatile installation methods and various power supply options to meet diverse requirements.

The metal rotor flowmeter stands as a quintessential tool in both industry and laboratories. It is celebrated for its straightforward structure, intuitive operation, minimal pressure loss, and easy maintenance. The rotor flowmeter is especially well-suited for measuring small flow rates in pipelines with a diameter of D.< 150 mm, and it can also measure the flow of corrosive media. When in use, the flowmeter must be installed in a vertical section of the pipe, with the fluid medium flowing from the bottom to the top through the rotor flowmeter.
Detailed Photos
 
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
Product Parameters
 
Technical parameters:
Technical parameters
Measuring range Water: 20~100000L/h Air:0.3~3000Nm /h
Refer to the flow meter
Range down 10:1(DN≤100mm) 5:1 (DN≤100mm)
Accuracy Standard Class 1.5 Special class 1.0
Pressure class (DN15, N25, D40, D50) 0~4.0MPa
(DN80, DN100, DN150)0~1.6MPa
Medium temperature Ordinary: -40ºC~100ºC High temperature:-80ºC~250ºC
Lining PTFE:-40ºC~
Ambient temperature Pointer type: -40ºC~+65ºC
Intelligent type: -25ºC~+65ºC
Connection type Flange, Thread, Clamping
Electrical interface M20×1.5 special can be customized
Protection grade IP67
Ex-proof class Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473
Medium viscosity DN15≤5Mpa.s (DN25~150)≤5Mpa.s
Power supply 3.6V lithium battery, 24VDC
Measuring pipe material 304, 316L, 304 or 316L, PTFE or F46
Float material 304 or 316L;PTFE or PFA
 
Flow sheet Float material: 1, Cr Ni steel 2, PTFE
Caliber Float No. Flow range H2O Flow range air Press loss Kpa
1 CrNiSteel PTFE 1 CrNiSteel  
DN15 F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 10 1/h
15 1/h
20 1/h
25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 I /h
160 1/h
200 I /h
220 I /h
250 I /h
280 I /h
300 I /h
350 I /h
400 1/h
450 1/h
500 1/h
600 1/h
700I/h
800 1/h
9001/h 1000 1/h



25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 1/h
160 1/h
200 1/h
220 1/h
250 1/h
280 1/h
300 1/h
350 1/h
400 1/h
0.30 Nm³/h
0.45 Nm³/h
0.60 Nm³/h
0.75 Nm³/h
0.90 Nm³/h
1.05 Nm³/h
1.20 Nm³/h
1.35 Nm³/h
1.50 Nm³/h
1.65 Nm³/h
1.80 Nm³/h
2.10 Nm³/h
2.40 Nm³/h
2.70 Nm³/h
3.00 Nm³/h
3.60 Nm³/h
4.80 Nm³/h
6.00 Nm³/h
6.60 Nm³/h
7.50 Nm³/h
8.40 Nm³/h
9.00 Nm³/h
10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³
1.5
 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5






D25
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7
F25.8 F25.9 F25.10 F25.11
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h 30.0 Nm³/h
36.0 Nm³/h
48.0 Nm³/h
60.0 Nm³/h
75.0 Nm³/h
90.0Nm³/h 105.0 Nm³/h
120.0 Nm³/h
135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³
1.5
1.5
3.0
3.0
3.5
3.5
8.0
8.0
8.0
16.0
16.0
16.0




D50
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h 3.0
3.0
4.0
4.0
4.0
8.0
8.0
16.0
16.0


D65
F65.0 F65.1 F65.2 F65.3 F65.4 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h 12000l/h 16000l/h 20000l/h 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/  



D80
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h 25000 I /h 30000 I /h 35000 I /h 40000 I /h 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h 14.0
14.0
14.0
22.0
22.0
25.0
25.0



D100
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h 50000l/h 60000 l/h 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h 30.0
30.0
30.0
30.0
40.0
40.0

D125
F125.0 F125.1 F125.2 100000 l/h 125000 l/h 150000 l/h 100000 l/h 125000 l/h 3000.0Nm³/h 3800.00 Nm³/h 45.0
45.0
48.0
 
Product selection
ZYZZ          A           B          C          D          E          F
Model   structure   wetting material   additional structure     caliber     medium       indicator
ZYZZ Metal pipe floating flowmeter


Standard is
A
Measuring pipe structure, A
A Down in, up out
B Up in, down out
C Side in, side out
D Bottom in, side out
E Right in, left out
F Left in, right out
G Clamp
H Thread connection



Standard is R1
Wetting material B Special consult with factory
R1 1Cr18Ni9Ti,304
RO 0cr18Ni12M02Ti,316
RL 316L
RP PTFE
Ni HC 276
Ti Titanium


Standard is N
Additonal structure C  
N No
Z Damping
J Clamping
G High temperature
L High pressure
Caliber DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200

Medium
Medium type E
L Liquid
G Gas


Standard is 5
M1  
M2  
M3  
M4  
M5  
  Power supply mode
Default A J Local indication no power supply
A 24V DC Two wire power supply 4-20 mA output
B Battery, field LCD display,no signal output
C 100VAC-240VAC 50HZ-60HZ,output 4-20mA

Default L
 Display
L With LCD
  X Without LCD


Defult N
Alarm selection
N No alarm
K1 Upper limit alarm
K2 Lower limit alarm
K3 UP and lower limit alarm


Default D
Ex-proof sign
N No
D Flame-proof ExdIICT6
I Intrinsic safety EX(ia)IICT6


Default N
N No communication protocol
H Hart protocol
M Modbus protocol
P PROfibus-PA field bus
Model selection example:ZYZZ/A/R1/M5/DN25
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol
 

 
Certifications
 
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to ensuring that your Good Repeatability Flowmeter, renowned for its high accuracy and versatile threaded mounting options, is delivered to you precisely as specified. Our unwavering commitment guarantees you will experience exceptional service, underpinned by our focus on punctual and efficient delivery tailored to meet your unique requirements.
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
Installation Instructions
 
Installation:

Introducing the metal rotor flowmeter, an advanced variable area flow measuring instrument crafted for precision through the float position measurement technique.

This device boasts an all-metal construction and adheres to a modular design ethos. Its compact size, minimal pressure loss, and impressive range ratio of 10:1,
coupled with straightforward installation and maintenance, make it an essential tool across numerous industries, especially in challenging and demanding environments.
A vital component for ensuring precise flow and process control, particularly for small flow rates, low velocities, and various specialized medium conditions.

Correct installation of the metal rotor flowmeter is crucial for optimal performance. Key installation guidelines to follow include:

(1) Ensure a vertical installation of the flowmeter, allowing the fluid to flow from the bottom upwards. Maintain a straight pipe length five times the instrument's diameter at both inlet and outlet. Newly installed pipelines require thorough flushing prior to fitting the flowmeter.

(2) Position a valve upstream, with a flow control valve 5 to 10 times the instrument's diameter downstream. For small diameter systems, incorporate a filter upstream. When dealing with magnetic mediums, a magnetic filter must precede the flowmeter.

(3) To simplify maintenance and replacement, integrate a bypass pipeline during installation.

(4) For mediums with high impurity levels, timely cleaning of both pipes and float is necessary.

(5) With a standard measurement accuracy level of 1.5, the metal rotor flowmeter is suitable for most applications. However, if enhanced accuracy is paramount, consider alternative flowmeter options.

Company and factory photos
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
Our Advantages
 
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD


Innovative Team Building

We firmly believe that a winning team is built on excellence, collaboration, and dedication! Our success is driven by a dynamic blend of exceptional skillsets and a shared vision for the future. Together, we strive for innovation that sets us apart, ensuring that every team member is empowered to contribute to our collective achievements.
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
Exhibition Highlights

We are proactively pursuing international partnerships by showcasing our innovations at global exhibitions. By presenting our cutting-edge technologies and forward-thinking solutions, we aim to forge valuable alliances and expand our reach across diverse markets. Our presence on the world stage underscores our commitment to innovation and excellence, opening doors to exciting new opportunities and collaborations.
4-20mA Output Anti-Interference Flowmeter with Reliable Structure and LCD
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now