Product Overview
The ZZYS30 Vortex Flowmeter is a sophisticated velocity flow instrument, expertly engineered to cater to a broad spectrum of applications.
Ideally designed for the precise measurement, vigilant monitoring, and meticulous control of the flow of liquids, steam, and a variety of gases.
Boasting a pioneering structure, it resists mechanical vibrations, impacts, and contamination, ensuring durability and reliability.
Thanks to its design devoid of moving parts, it experiences no wear and tear, requires no mechanical maintenance, offers low pressure loss, and maintains stable, high-precision performance.
Installation is a breeze, with customizable sensor and signal converter matching to suit specific needs.
Product Features:
Versatile application range, adept at measuring the flow rates of steam, gas, and liquids with exceptional accuracy.
Outstanding vibration resistance, maintaining zero drift at zero point, and effectively negating the effects of external vibrations.
The ZZY30 offers integrated temperature and pressure measurement options, significantly reducing installation costs for users.
Flexible output options including (0-5) kHz frequency output, (4-20) mA output, or advanced HART/Modbus protocol communication.
Supports convenient parameter setting via Bluetooth communication. Built to be wear-resistant, dirt-resistant, eliminating the need for mechanical maintenance, ensuring long service life, and featuring explosion-proof safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Available in 25, 32, 50, 80, 100 mm.
Flange Connection Type: Caliber sizes available are 100, 150, 200 mm.
Flow Measurement Range: Normal measurement flow velocity range with Reynolds number 1.5×10^4~4×10^6; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: Refer to Table 2.
Steam Flow Range: Refer to Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle is approximately 50%, with a transmission distance of 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, with a transmission distance of 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH at 50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC 24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.
PACKING & SHIPPING
We will promptly deliver your order to meet your requested timeline, ensuring the earliest possible delivery date as per your requirements.Installation Requirements
Piping Condition
The installation of vortex flowmeter requires a specific straight pipe section both before and after the meter. Common configurations are as follows (D represents the pipe diameter):
1.
The sensor should be installed on a horizontal, vertical, or inclined pipe (with the liquid flowing bottom to top) that matches the sensor's diameter. Ensure a straight pipe section of 15-20D upstream and 5-10D downstream.
2.
The pipe near the sensor should be fully filled with the liquid being measured.
3.
Avoid installing the sensor on pipes with significant mechanical vibrations.
4.
The inner diameter of the straight pipe section should match the sensor's diameter as closely as possible. If not, use a slightly larger pipe with a diameter error of ≤3% and not exceeding 5mm. Avoid areas with strong electromagnetic interference, cramped spaces, or where maintenance is inconvenient..
5.
Horizontal pipeline installation is common. For gas flow with some liquid, install the sensor at a higher point. For liquid flow with some gas, install it at a lower point.
6.
Vertical pipeline sensor installation is permissible. For gas flow, install without direction restrictions. If the gas has some liquid, flow should be bottom to top. For liquid flow, ensure it goes bottom to top to avoid extra weight on the probe.
7.
Side installation on horizontal pipelines is applicable for all fluids, especially for superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier.
8.
Inverted installation on horizontal pipelines is generally discouraged. It's unsuitable for common gases or superheated steam but can measure saturated steam and high-temperature liquids or in situations requiring frequent pipeline cleaning.
9.
For insulated pipelines with high-temperature steam, ensure the insulation layer is no more than one-third of the bracket height.
10.
Pressure and temperature measurement points should be positioned based on measurement needs. The pressure point should be 3-5D downstream, and the temperature point 6-8D downstream of the sensor.