Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement

Product Details
Customization: Available
After-sales Service: 24/7 After Sales Services
Warranty: 12 Months From Delivery
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
  • Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZZYS30
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 50.00cm
Package Gross Weight
5.000kg

Product Description

Product Description

Product Overview

The ZZYS30 Vortex Flowmeter is a sophisticated velocity flow instrument, expertly engineered to cater to a broad spectrum of applications.
Ideally designed for the precise measurement, vigilant monitoring, and meticulous control of the flow of liquids, steam, and a variety of gases.
Boasting a pioneering structure, it resists mechanical vibrations, impacts, and contamination, ensuring durability and reliability.
Thanks to its design devoid of moving parts, it experiences no wear and tear, requires no mechanical maintenance, offers low pressure loss, and maintains stable, high-precision performance.
Installation is a breeze, with customizable sensor and signal converter matching to suit specific needs.


Product Features:

Versatile application range, adept at measuring the flow rates of steam, gas, and liquids with exceptional accuracy.
Outstanding vibration resistance, maintaining zero drift at zero point, and effectively negating the effects of external vibrations.
The ZZY30 offers integrated temperature and pressure measurement options, significantly reducing installation costs for users.
Flexible output options including (0-5) kHz frequency output, (4-20) mA output, or advanced HART/Modbus protocol communication.
Supports convenient parameter setting via Bluetooth communication. Built to be wear-resistant, dirt-resistant, eliminating the need for mechanical maintenance, ensuring long service life, and featuring explosion-proof safety.

Detailed Photos

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Product Parameters

Technical Index

Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Available in 25, 32, 50, 80, 100 mm.
Flange Connection Type: Caliber sizes available are 100, 150, 200 mm.
Flow Measurement Range: Normal measurement flow velocity range with Reynolds number 1.5×10^4~4×10^6; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: Refer to Table 2.
Steam Flow Range: Refer to Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle is approximately 50%, with a transmission distance of 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, with a transmission distance of 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH at 50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC 24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)

Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028

Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8

Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630


Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660

Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure

Certifications

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement

PACKING & SHIPPING

We will promptly deliver your order to meet your requested timeline, ensuring the earliest possible delivery date as per your requirements.
Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Installation Instructions

Installation Requirements

Piping Condition
The installation of vortex flowmeter requires a specific straight pipe section both before and after the meter. Common configurations are as follows (D represents the pipe diameter):

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D

1.
The sensor should be installed on a horizontal, vertical, or inclined pipe (with the liquid flowing bottom to top) that matches the sensor's diameter. Ensure a straight pipe section of 15-20D upstream and 5-10D downstream.
2.
The pipe near the sensor should be fully filled with the liquid being measured.
3.
Avoid installing the sensor on pipes with significant mechanical vibrations.
4.
The inner diameter of the straight pipe section should match the sensor's diameter as closely as possible. If not, use a slightly larger pipe with a diameter error of ≤3% and not exceeding 5mm. Avoid areas with strong electromagnetic interference, cramped spaces, or where maintenance is inconvenient..
5.
Horizontal pipeline installation is common. For gas flow with some liquid, install the sensor at a higher point. For liquid flow with some gas, install it at a lower point.
6.
Vertical pipeline sensor installation is permissible. For gas flow, install without direction restrictions. If the gas has some liquid, flow should be bottom to top. For liquid flow, ensure it goes bottom to top to avoid extra weight on the probe.
7.
Side installation on horizontal pipelines is applicable for all fluids, especially for superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier.
8.
Inverted installation on horizontal pipelines is generally discouraged. It's unsuitable for common gases or superheated steam but can measure saturated steam and high-temperature liquids or in situations requiring frequent pipeline cleaning.
9.
For insulated pipelines with high-temperature steam, ensure the insulation layer is no more than one-third of the bracket height.
10.
Pressure and temperature measurement points should be positioned based on measurement needs. The pressure point should be 3-5D downstream, and the temperature point 6-8D downstream of the sensor.

Company Profile

Shandong Zhongziyi Intelligent Technology Co., Ltd.
Located in Zibo Science and Technology Industrial Park,
our company spans an impressive 18,000.00 square meters.
We boast a high-standard, modern manufacturing facility and are
dedicated to
the research and development (R&D),
manufacturing,
sales, and service of precision pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we've secured ISO9001 quality management system certification and are recognized as a high-tech enterprise in Shandong Province.
We are a close partner of Rosemount in China, consistently aligning our technology advancements with theirs.
With nearly 60 years of deep engagement in instrument R&D and production,
we have accumulated significant technological expertise and customer service experience.
Our products are extensively used in Petroleum, Chemical Industry, Papermaking,
Metallurgy,
Medicine,
Food,
Power and Machinery industries, covering the entire nation and beyond, earning widespread trust and praise from our users.
Our company's core philosophy is "quality first, customer first."
We warmly welcome customers to visit our factory and discuss potential business collaborations.

COMPANY AND FACTORY PICTURE:

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Our Advantages

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Features:
  1. The structure is ingeniously simple yet exceptionally robust, featuring no moving parts. This design delivers remarkable reliability and ensures a prolonged, dependable performance.Operation remains highly dependable over extensive periods.
  1. Installation is a breeze, offering straightforward procedures, and maintenance is incredibly convenient.
  1. The detection sensor is ingeniously designed to avoid direct contact with the measured medium, guaranteeing consistent, stable performance and an extended lifespan.
  1. The device outputs a pulse signal directly proportional to the flow rate, ensuring no zero drift and maintaining high accuracy throughout its operation.
  1. It boasts a wide measurement range,with a turndown ratioup to an impressive 1:50.
  1. Featuring low pressure loss, the flowmeter ensures reduced operating costs and significant energy-saving benefits. Within a specific range of Reynolds numbers, the output signal frequency remains unaffected by changes in the fluid's physical properties and composition. The meter coefficient solely depends on the vortex shedding body’s shape and size, eliminating the need for compensation when measuring fluid volume flow. Typically,recalibration of the meter coefficient is unnecessary even after component changes.


Team Building

We firmly believe that the best team wins, striving for excellence in all endeavors.

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
Exhibition Pictures

We are actively seeking international cooperation through various exhibitions abroad, continually expanding our global footprint.

Low Pressure Loss Vortex Flowmeter for Steam and Gas Measurement
FAQ

1. What kind of product do you supply?

O
ur product
includes:
pressure transmitters, temperature transmitters, level transmitters, pressure gauges, temperature gauges, and flow
meters.

2. What are your product and technology advantages?

Our factory was established in 1966, boasting nearly 60 years of unparalleled manufacturing and R&D expertise. We are also a highly esteemed partner of Rosemount in
China.
Our technology closely
follows Rosemount's innovations. Notably, our remote pressure transmitter technology and stability are considered the best in China.

3. Where is your factory located?

O
ur factory is situated in Zibo, Shandong province, China, one of the top
three
instrument production areas.
A
nd we occupy more than 18,000 square meters.

4. Can we visit your factory?

Y
ou are always welcome to visit our factory at any time that suits you.

5. What is the warranty of your product?

O
ur product warranty lasts 12 months from the shipping date, and we also provide
lifetime
maintenance.

6. What are your payment terms?

Currently
, we can accept a 50% down payment and the remaining 50% payable 5 days before delivery via T/T, Western Union,
PayPal
, and trade assurance online payment.

7. What kind of certification do you have?

W
e hold ISO9001, CCC, CNAS laboratory accreditation, Flame-proof certification, Intrinsic Safety certification, SIL certificate, ECM certificate, Russia EAC and PAC certificates,
a
nd
several
invention patents.

8. How long is your delivery date?

F
or peak seasons, it is 4 weeks and 2 weeks for the off-season. Regardless of the season, we strive to meet your requirements.

9. How is your after-sales service?

Our products enjoy an excellent reputation for quality, with almost no warranty issues arising from the products themselves. Nonetheless, we offer 24/7 online
services for any installation, commissioning, operational, or other issues you might encounter.

10. How can I send an inquiry?

Y
ou can send an inquiry through our email or cellphone as provided below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now