The ZZYS30 Vortex Flowmeter: a high-precision, velocity flow instrument designed for versatile applications.
Perfect for measuring, monitoring, and controlling the flow of liquids, steam, and a variety of gases, ensuring optimal performance in diverse environments.
Boasts an innovative structure that resists mechanical vibrations, impacts, and contamination for enhanced durability and reliability.
Engineered with no moving parts to eliminate wear and tear, requiring no mechanical maintenance. Features low pressure loss, stable performance, and high accuracy.
Easy installation process with customizable sensor and signal converter configurations to meet specific needs.
Product Features:
Extremely versatile, this flowmeter is ideal for measuring steam, gas, and liquid flows across various applications.
Superior vibration resistance with zero point zero drift, effectively negating external vibration influences.
The ZZY30 offers integrated temperature and pressure options, significantly reducing installation costs for users.
Supports frequency output (0-5 kHz), (4-20) mA output, as well as HART communication/Modbus protocol communication for seamless integration.
Enables parameter setting via Bluetooth communication. Wear-resistant, dirt-resistant, requiring no mechanical maintenance, ensuring a long service life and explosion-proof safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100.
Flange Connection Type Caliber Selection: 100, 150, 200.
Flow Measurement Range: Normal measurement flow velocity range - Reynolds Number: 1.5×10~4×10; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: See Table 2.
Steam Flow Range: See Table 3.
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature:
Room Temperature: -25ºC to 100ºC; High Temperature: -25ºC to 150ºC, -25ºC to 250ºC Output Signal: Pulse Voltage Output Signal, High Level: 8~10V, Low Level: 0.7~1.3V; Pulse Duty Cycle: ~50%; Transmission Distance: 100m
Pulse Current Remote Transmission Signal: 4-20 mA; Transmission Distance: 1000m Instrument Use Environment: Temperature: -25ºC to +55ºC; Humidity: 5% to 90% RH at 50ºC Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6; Protection Level: IP65.
PACKING & SHIPPING
Your order will be delivered promptly to meet your specified requirements, ensuring the earliest possible dispatch.Installation Requirements
Piping Condition
The installation of the Vortex Flowmeter requires specific straight pipe sections both upstream and downstream. The common configurations based on pipe diameter (D) are as follows:
1.
The sensor should be installed on a pipe that is horizontal, vertical, or inclined (with the liquid flowing from bottom to top) and matches the sensor's diameter. Ensure a straight pipe section of 15-20D upstream and 5-10D downstream.
2.
The pipe near the liquid sensor must be filled with the liquid being measured.
3.
Do not install the sensor on pipes with strong mechanical vibrations.
4.
The inner diameter of the straight pipe should be consistent with the sensor's diameter. If it differs, a slightly larger diameter pipe (≤3% error, not exceeding 5mm) should be used. Avoid locations with strong electromagnetic interference, limited space, or inconvenient maintenance..
5.
Horizontal pipeline installation is the most common for flow sensors. When measuring gas flow containing a small amount of liquid, install the sensor at a higher point on the pipeline. For liquid flow containing a small amount of gas, install the sensor at a lower point.
6.
Vertical pipeline installation: For gas flow, install the sensor on a vertical pipeline without flow direction restriction. If the gas contains liquid, the flow should be from bottom to top. For liquid flow, ensure the flow is from bottom to top to prevent additional weight on the probe.
7.
Side installation on horizontal pipelines: Suitable for all fluids, especially superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier and is preferred if conditions allow.
8.
Inverted installation on horizontal pipelines: Generally not recommended for general gases or superheated steam but can be used for saturated steam and high-temperature liquids or in situations requiring frequent pipeline cleaning.
9.
For pipelines with insulation layers, when measuring high-temperature steam, ensure the insulation does not exceed one-third of the bracket height.
10.
Pressure and temperature measurement points: Depending on requirements, place the pressure measurement point 3-5D downstream of the sensor and the temperature measurement point 6-8D downstream.