Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use

Product Details
Customization: Available
After-sales Service: 24/7 After Sales Services
Warranty: 12 Months From Delivery
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
  • Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZZYS30
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Product Description

Product Description

Product Overview

The ZZYS30 Vortex Flowmeter: a high-precision, velocity flow instrument designed for versatile applications.
Perfect for measuring, monitoring, and controlling the flow of liquids, steam, and a variety of gases, ensuring optimal performance in diverse environments.
Boasts an innovative structure that resists mechanical vibrations, impacts, and contamination for enhanced durability and reliability.
Engineered with no moving parts to eliminate wear and tear, requiring no mechanical maintenance. Features low pressure loss, stable performance, and high accuracy.
Easy installation process with customizable sensor and signal converter configurations to meet specific needs.


Product Features:

Extremely versatile, this flowmeter is ideal for measuring steam, gas, and liquid flows across various applications.
Superior vibration resistance with zero point zero drift, effectively negating external vibration influences.
The ZZY30 offers integrated temperature and pressure options, significantly reducing installation costs for users.
Supports frequency output (0-5 kHz), (4-20) mA output, as well as HART communication/Modbus protocol communication for seamless integration.
Enables parameter setting via Bluetooth communication. Wear-resistant, dirt-resistant, requiring no mechanical maintenance, ensuring a long service life and explosion-proof safety.

Detailed Photos

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Product Parameters

Technical Index

Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100.
Flange Connection Type Caliber Selection: 100, 150, 200.
Flow Measurement Range: Normal measurement flow velocity range - Reynolds Number: 1.5×10~4×10; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: See Table 2.
Steam Flow Range: See Table 3.
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature:
Room Temperature: -25ºC to 100ºC; High Temperature: -25ºC to 150ºC, -25ºC to 250ºC Output Signal: Pulse Voltage Output Signal, High Level: 8~10V, Low Level: 0.7~1.3V; Pulse Duty Cycle: ~50%; Transmission Distance: 100m
Pulse Current Remote Transmission Signal: 4-20 mA; Transmission Distance: 1000m Instrument Use Environment: Temperature: -25ºC to +55ºC; Humidity: 5% to 90% RH at 50ºC Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6; Protection Level: IP65.

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)

Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028

Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8

Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630


Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660

Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure

Certifications

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use

PACKING & SHIPPING

Your order will be delivered promptly to meet your specified requirements, ensuring the earliest possible dispatch.
Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Installation Instructions

Installation Requirements

Piping Condition
The installation of the Vortex Flowmeter requires specific straight pipe sections both upstream and downstream. The common configurations based on pipe diameter (D) are as follows:

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D

1.
The sensor should be installed on a pipe that is horizontal, vertical, or inclined (with the liquid flowing from bottom to top) and matches the sensor's diameter. Ensure a straight pipe section of 15-20D upstream and 5-10D downstream.
2.
The pipe near the liquid sensor must be filled with the liquid being measured.
3.
Do not install the sensor on pipes with strong mechanical vibrations.
4.
The inner diameter of the straight pipe should be consistent with the sensor's diameter. If it differs, a slightly larger diameter pipe (≤3% error, not exceeding 5mm) should be used. Avoid locations with strong electromagnetic interference, limited space, or inconvenient maintenance..
5.
Horizontal pipeline installation is the most common for flow sensors. When measuring gas flow containing a small amount of liquid, install the sensor at a higher point on the pipeline. For liquid flow containing a small amount of gas, install the sensor at a lower point.
6.
Vertical pipeline installation: For gas flow, install the sensor on a vertical pipeline without flow direction restriction. If the gas contains liquid, the flow should be from bottom to top. For liquid flow, ensure the flow is from bottom to top to prevent additional weight on the probe.
7.
Side installation on horizontal pipelines: Suitable for all fluids, especially superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier and is preferred if conditions allow.
8.
Inverted installation on horizontal pipelines: Generally not recommended for general gases or superheated steam but can be used for saturated steam and high-temperature liquids or in situations requiring frequent pipeline cleaning.
9.
For pipelines with insulation layers, when measuring high-temperature steam, ensure the insulation does not exceed one-third of the bracket height.
10.
Pressure and temperature measurement points: Depending on requirements, place the pressure measurement point 3-5D downstream of the sensor and the temperature measurement point 6-8D downstream.

Company Profile

Shandong Zhongziyi Intelligent Technology Co., Ltd.
Strategically situated in the heart of Zibo Science and Technology Industrial Park,
our expansive facility spans over 18,000 square meters.
Equipped with state-of-the-art manufacturing technologies,
we are passionately committed to
the research and development,
manufacturing,
sales, and service of precision pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we proudly hold the ISO9001 quality management system certification. We are also recognized as a high-tech enterprise within Shandong Province.
We are a premier partner of Rosemount in China, consistently aligning our technology with their advanced innovations.
With nearly six decades of dedicated involvement in instrument research and production,
we have amassed substantial technological expertise and exceptional customer service experience.
Our products are extensively utilized in the Petroleum, Chemical, Papermaking,
Metallurgy,
Medicine,
Food,
Power, and Machinery industries, among others. Our sales network spans nationwide and extends globally, earning the trust and commendation of numerous users.
Our core philosophy is rooted in 'quality first, customer first.'
We warmly invite customers to visit our factory for an in-depth tour and to explore potential business collaborations.

COMPANY AND FACTORY PICTURE:

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Our Advantages

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Features:
  1. The structure is simple yet robust, with no moving parts, ensuring high reliability and exceptional longevity.Operation is consistently dependable.
  1. Installation is straightforward, and maintenance is remarkably convenient.
  1. The detection sensor does not directly contact the measured medium, guaranteeing stable performance and an extended lifespan.
  1. The output delivers a pulse signal proportional to the flow rate, featuring no zero drift and outstanding accuracy.
  1. Wide measurement range,with range down up to 1:50.
  1. Low pressure loss, minimal operating costs, and notable energy-saving benefits. Within a specific range of Reynolds numbers, the output signal frequency remains unaffected by changes in the physical properties and composition of the fluid. The meter coefficient is exclusively related to the shape and size of the vortex shedding body, eliminating the need for fluid volume flow compensation. Generally,recalibration of the meter coefficient is unnecessary after changing components.


Team Building

We trust that the best team always wins!

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
Exhibition Pictures

We are actively seeking international cooperation through global exhibitions.

Low Pressure Loss Wear Resistant Vortex Flowmeter for Gas Use
FAQ

1. What kind of products do you supply?

O
ur product offerings
include
pressure transmitters, temperature transmitters, level transmitters, pressure gauges, temperature gauges, and flow
meters.

2. What are your product and technology advantages?

Our factory, established in 1966, boasts nearly 60 years of manufacturing and R&D expertise. We are a highly esteemed partner of Rosemount in
China.
Our technology is closely
aligned with Rosemount. Notably, our remote pressure transmitter technology and stability are among the best in China.

3. Where is your factory located?

O
ur factory is situated in Zibo, Shandong province, China, a top
three
instrument production area.
A
nd spans an area of over 18,000 square meters.

4. Can we visit your factory?

Y
ou are always welcome to visit our factory at your convenience.

5. What is the warranty on your products?

O
ur product warranty is 12 months from the shipping date, but we also provide
lifetime
maintenance.

6. What are your payment terms?

Currently
, we accept a 50% down payment with the remaining 50% payable 5 days before delivery via T/T, Western Union,
PayPal,
and Trade Assurance online payments.

7. What kind of certifications do you have?

W
e possess ISO9001 certification, CCC, CNAS laboratory accreditation, Flame-proof certification, intrinsic safety certification, SIL certificate, ECM certification, and Russia EAC and PAC certifications, as well as
a
number of
invention
patents.

8. How long is your delivery time?

D
uring peak season, the delivery time is 4 weeks, and it is 2 weeks during the off-season. Regardless of the season, we strive to meet your requirements.

9. How is your after-sales service?

Our products are renowned for their quality and have an excellent reputation, with minimal warranty claims. Nonetheless, we provide 24/7 online
support for any installation, commissioning, operation, or other concerns.

10. How can I send an inquiry?

Y
ou can send your inquiry via our email or cellphone detailed below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now