Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss

Product Details
Customization: Available
After-sales Service: 24/7 After Sales Services
Warranty: 12 Months From Delivery
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
  • Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZZYS30
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 50.00cm
Package Gross Weight
5.000kg

Product Description

Product Description

Product Overview

The ZZYS30 vortex flowmeter, an advanced velocity flow instrument, serves a multitude of applications with exceptional precision.
Perfectly designed for measuring, monitoring, and controlling the flow of liquids, steam, and most gases, ensuring versatile utility.
Boasting a revolutionary structure that withstands mechanical vibrations, impacts, and contamination, this device is built for resilience.
With a design free of moving parts, it eliminates wear and tear, requires no mechanical maintenance, and guarantees low pressure loss, stable performance, and high accuracy.
Installation is a breeze, with the capability to match the sensor and signal converter as required for optimal performance.


Product features:

Wide application range, efficiently measuring the flow of steam, gas, and liquid, making it incredibly adaptable.
Superior vibration performance ensures zero drift at zero point, effectively negating the impact of external vibrations.
The ZZY30 offers integrated temperature and pressure options, significantly reducing installation costs for users.
Supports multiple communication protocols including (0-5) kHz frequency output, (4-20) mA output, and HART/Modbus communication.
Parameter settings can be adjusted via Bluetooth communication. The device is wear-resistant, dirt-resistant, maintenance-free, boasts a long service life, and is explosion-proof for enhanced safety.

Detailed Photos

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Product Parameters

Comprehensive Technical Index

Measurement Medium: Versatile for Gas, Liquid, and Steam
Connection Methods: Flange Clamp Type, Flange Type, and Insertion Type
Caliber Specifications:
Flange Clamping Type Caliber Options: 25, 32, 50, 80, 100.
Flange Connection Type Caliber Selection: 100, 150, 200
Flow Measurement Range: Standard Flow Velocity Range with Reynolds Number 1.5×104~4×106; Gas Flow 5~50m/s; Liquid Flow 0.5~7m/s.
Standard Flow Measurement Range for Liquid
Gas Flow Measurement Range: Refer to Table 2.
Steam Flow Range: Refer to Table 3.
Measurement Accuracy: Available in 1.0 Class and 1.5 Class
Measured Medium Temperature Range:
Room Temperature: -25ºC~100ºC, High Temperature: -25ºC~150ºC and -25ºC~250ºC. Output Signal: Pulse Voltage Output Signal with High Level 8~10V, Low Level 0.7~1.3V. Pulse Duty Cycle is Approximately 50%, with a Transmission Distance of 100m.
Pulse Current Remote Transmission Signal: 4-20 mA with a Transmission Distance of 1000m. Instrument Usage Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH50ºC. Material Composition: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level IP65.

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)

Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028

Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8

Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630


Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660

Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure

Certifications

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss

PACKING & SHIPPING

We ensure to deliver your ordered product at the earliest date as per your requirement, guaranteeing prompt and efficient service.
Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Installation Instructions

Installation Requirements

Piping Condition
The installation of a vortex flowmeter necessitates a designated section of straight piping both before and after the meter. The typical configurations are as follows (D represents the diameter of the pipe):

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D

1.
The sensor must be installed on a pipe that is horizontal, vertical, or inclined (with the liquid flowing from bottom to top) and matches the sensor's diameter. There should be a specified length of straight pipe upstream and downstream of the sensor. The front straight pipe section should range from 15-20D, while the rear should be 5-10D.
2.
The pipe near the liquid sensor must be filled with the liquid being measured.
3.
The sensor must not be installed on pipes experiencing strong mechanical vibrations.
4.
The inner diameter of the straight pipe section should closely match the sensor diameter. If identical diameters are not possible, a slightly larger pipe should be used, with an allowable error of ≤3% and not exceeding 5mm. Avoid installing the sensor in areas with strong electromagnetic interference, restricted space, or where maintenance is inconvenient. Adherence to installation requirements is crucial..
5.
Horizontal pipeline installation is the most common method for flow sensors. When measuring gas flow, if the gas contains a small amount of liquid, the sensor should be positioned at a higher point in the pipeline. When measuring liquid flow, if the liquid contains a small amount of gas, the sensor should be placed at a lower point in the pipeline.
6.
Sensor installation in vertical pipelines: When measuring gas flow, the sensor can be installed without any restriction on flow direction. If the gas contains a small amount of liquid, the gas flow should be from bottom to top. For liquid flow, the liquid should ascend to prevent additional weight on the probe.
7.
Side installation of sensors on horizontal pipelines: Regardless of the fluid being measured, sensors can be side-mounted. This method is especially suitable for superheated steam, saturated steam, and low-temperature liquids. If conditions permit, side mounting is preferred as it reduces the temperature impact on the amplifier.
8.
Inverted installation of sensors on horizontal pipelines: Generally not recommended. This method is unsuitable for general gases or superheated steam but can be used for saturated steam and high-temperature liquids or when pipelines require frequent cleaning.
9.
Installation of sensors on pipelines with insulation: When dealing with high-temperature steam, the insulation layer should not exceed one-third of the bracket height.
10.
Selection of pressure and temperature measurement points: Depending on measurement requirements, the pressure measurement point should be 3-5D downstream of the sensor, and the temperature measurement point should be 6-8D downstream of the sensor.

Company Profile

Shandong Zhongziyi Intelligent Technology Co., Ltd.
Located in the prestigious Zibo Science and Technology Industrial Park,
our company spans an impressive area of over 18,000 square meters.
We boast a high-standard, modern manufacturing facility, and
are committed to
the research and development (R&D),
manufacturing,
sales, and service of advanced pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we are proud to have obtained ISO9001 quality management system certification and to be recognized as a high-tech enterprise in Shandong Province.
We are a close strategic partner of Rosemount in China, continuously aligning our technology with their advancements.
For nearly 60 years, our factory has been deeply engaged in the R&D and production of high-quality instruments,
accumulating extensive technological expertise and customer service experience.
Our products are widely used in industries such as petroleum, chemical processing, papermaking,
metallurgy,
medicine,
food production,
power generation, and machinery. Our sales network covers the entire country and extends abroad, earning deep trust and favorable reviews from a wide range of users.
The company's core goal is "quality first, customer first."
We warmly welcome customers to visit our factory and discuss cooperation opportunities.

COMPANY AND FACTORY PICTURE:

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Our Advantages

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Features:
  1. The structure of the Steam Vortex Flowmeter is elegantly simple yet impressively robust. With no moving parts, this device ensures high reliability and long-term stability.Its operation is highly dependable, guaranteeing consistent performance over time.
  1. Installation is remarkably straightforward, and maintenance is exceptionally convenient.
  1. The detection sensor is ingeniously designed to avoid direct contact with the measured medium, ensuring stable performance and an extended lifespan.
  1. The output is a pulse signal precisely proportional to the flow rate, featuring no zero drift and maintaining high accuracy.
  1. This flowmeter boasts a wide measurement range,with a turndown ratioas high as 1:50.
  1. It ensures low pressure loss, minimizes operating costs, and delivers substantial energy-saving benefits. Within a specific range of Reynolds numbers, the output signal frequency remains unaffected by changes in the fluid's physical properties and composition. The meter coefficient is solely dependent on the shape and size of the vortex shedding body, eliminating the need for compensation when measuring fluid volume flow. Generally,recalibration of the meter coefficient is unnecessary after component replacements.


Team Building

We firmly believe that the best team always wins!

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
Exhibition Pictures

We are proactively seeking international cooperation through participation in global exhibitions.

Steam Vortex Flowmeter with Anti Vibration and Low Pressure Loss
FAQ

1, What kind of product do you supply?

O
ur product
includes
pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow
meter.

2,What is your product and technology advantages?

Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in
China.
our technology closely
keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

O
ur factory located in Zibo, Shandong province, China, which is top
three
instrument production area.
A
nd take an area of more than 18000 square meters.

4, Can we visit your factory?

Y
ou are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

O
ur product warranty is 12 months from the shipping date, but we provide
lifetime
maintenance.

6, What are your payment terms?

Now
, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union,
PayPal
and trade assurance online payment.

7, What kind of certification do you have?

W
e have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate
a
nd
several
invention patents.

8, How long is your delivery date?

F
or peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

Our products quality enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

Y
ou can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now