Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are passionately committed to delivering your Explosion Proof Electromagnetic Flowmeter with High Accuracy and IP67 Protection at the earliest possible date. We guarantee prompt and efficient service tailored to meet your specific requirements.The installation of the Explosion Proof Electromagnetic Flowmeter with High Accuracy and IP67 Protection from Shandong Zhongziyi Intelligent Technology Co., Ltd. varies depending on the site pipeline conditions. Flowmeters without a ball valve are suitable for non-pressurized pipelines, allowing for easier selection and installation.
A hole with a diameter of 50mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline for secure installation.
For scenarios requiring continuous flow during loading and unloading or where media overflow is not permitted, an insertion-type electromagnetic flowmeter with a ball valve structure should be selected. This ensures uninterrupted operation and safety.
A hole with a diameter of 50mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The requirements for the straight pipe sections are 5D upstream and 3D downstream, ensuring the proper performance and accuracy of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of flow characteristics, providing reliable measurements.
Even if turbulence and vortices are generated in the non-measurement area of the pipeline (e.g., elbows, tangential throttling, or partially open shut-off valves upstream), it will not impact the measurement accuracy.
However, steady-state vortices within the measurement area can affect both stability and accuracy, necessitating corrective measures.
In such cases, consider the following measures to stabilize the flow distribution:
1.2. Pipeline-Type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. A flow straightener can also be installed, and it is advisable to avoid installation close to control valves and partially open valves to ensure measurement accuracy.
2.2. Requirements for the Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point to maintain measurement accuracy: a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter, within the range of 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes: To ensure seamless maintenance of the flowmeter, it is highly recommended to integrate a bypass pipe. For environments dealing with heavily contaminated fluids or where uninterrupted cleaning of the flowmeter is necessary, a bypass pipe installation is imperative. a. Facilitates seamless maintenance. b. Essential for managing heavily contaminated fluids. c. Allows cleaning of the flowmeter without halting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters: Precise guidelines for setting up insertion-type electromagnetic flowmeters to enhance efficiency and accuracy.
3.1. Requirements for Straight Pipe Sections: Ensure optimal operation by maintaining adequate straight pipe sections. Inlet straight pipe sections should be ≥ 10×DN, while outlet straight pipe sections should be ≥ 5×DN.
3.2. Requirements for Grounding Points: To guarantee reliable performance and enhanced measurement accuracy, the sensor must be well-grounded with a grounding resistance of less than 10. Avoid interference from external parasitic potentials. (Note: If the metal pipeline is properly grounded, additional grounding devices are not necessary.)
3.3. Requirements for Installation Position: Refer to the accompanying diagram for precise installation positioning to ensure optimal performance.
COMPANY AND FACTORY PICTURE: A visual representation of Shandong Zhongziyi Intelligent Technology Co., Ltd. showcasing our state-of-the-art facilities and dedicated team.