Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service.The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on non-pressurized pipelines, as this allows for the selection of flowmeters without a ball valve.
A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
For situations requiring continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The requirements for the straight pipe sections are 5D upstream and 3D downstream to ensure the proper use of the electromagnetic flowmeter and meet the accuracy requirements.
The measurement principle of the electromagnetic flowmeter does not depend on the characteristics of the flow.
If there is a certain amount of turbulence and vortices generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), it will not affect the measurement.
However, if there are steady-state vortices in the measurement area, it will affect the stability and accuracy of the measurement.
In this case, some measures should be taken to stabilize the flow distribution:
1.2. Pipeline-type electromagnetic flowmeter
2.1. Requirements for straight sections To mitigate the effects of vortices and flow field distortion, there are specific requirements for the lengths of the straight pipe sections upstream and downstream of the flowmeter; otherwise, measurement accuracy will be affected (a straightener can also be installed, and it is advisable to avoid installation close to control valves and partially open valves).
2.2. Requirements for the process pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should be the same as that of the sensor and must meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. This is especially crucial for applications involving heavily contaminated fluids and scenarios where the flowmeter must be cleaned without interrupting the fluid flow. a. Essential for easy maintenance of the flowmeter. b. Mandatory for applications with heavily contaminated fluids. c. Imperative in situations where fluid flow cannot be halted during cleaning operations.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections For optimal performance, ensure the following straight pipe sections: Inlet should be ≥ 10×DN, and Outlet should be ≥ 5×DN.
3.2. Requirements for Grounding Points To guarantee the reliable operation of the instrument and enhance measurement precision, it is crucial to avoid interference from external parasitic potentials. The sensor must be grounded effectively, with a grounding resistance of less than 10Ω. (If the metal pipeline is already well-grounded, a dedicated grounding device is not required.)
3.3. Requirements for Installation Position Refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: