Zydc High Accuracy Flowmeter for Consistent Fluid Measurement

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
  • Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg
Lead Time
7 days (1 - 5 Pieces)
To be negotiated ( > 5 Pieces)

Product Description

Product Description

 

Prodution overview
                
Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter consists of two parts: a sensor and a converter. It operates based on Faraday's electromagnetic induction law and is used to measure conductive fluids. The ZYDC electromagnetic flow meter is a high-precision and highly reliable product that has been continuously upgraded and improved. This flow meter has achieved a leading level in the country in terms of excitation technology, lining technology, and intelligent technology, and complies with relevant standards such as JB/T9248-2015 and JJG 1033-2007.


Features:

- Stable performance, good repeatability, and high accuracy (up to 0.2%).
- No flow obstruction components, no pressure loss, and not easily clogged.
 - Good adaptability to highly corrosive and highly abrasive media.
- Enables operation without opening the cover through mobile Bluetooth and infrared remote control.
- Utilizes stainless steel mesh technology, suitable for use under negative pressure.
 - Supports GPRS and Bluetooth wireless transmission; compatible with communication protocols such as MODBUS and HART.
- Employs a 16-bit embedded microprocessor for fast computation speed, high precision, and programmable low-frequency square wave excitation, enhancing flow measurement stability with low power consumption.
- Utilizes SMD components and surface mount technology (SMT) for high circuit reliability. - Allows online modification of measurement range based on actual user needs in the field, better matching with data acquisition terminals.
- The measurement results are independent of fluid pressure, temperature, density, viscosity, and other physical parameters.
 - It features digital communication signal outputs such as RS485, RS232, HART, Modbus, and Profibus-DP (optional).
- It has self-check, self-diagnosis, and alarm functions.
- There are three internal accumulators that can separately display forward cumulative amount, reverse cumulative amount, and differential cumulative amount. An internal clock is set to record up to 16 power outage times (optional).
 - The ultra-low EMI switch power supply is suitable for a wide range of power supply voltage variations and has good EMI resistance.

 

Detailed Photos

 

Zydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid MeasurementZydc High Accuracy Flowmeter for Consistent Fluid Measurement

 

Product Parameters

 

Technical parameters:
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have

Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W

Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  


 

Certifications

 

 
 
 
Zydc High Accuracy Flowmeter for Consistent Fluid Measurement



PACKING & SHIPPING

We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service.
Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
Installation Instructions
 

  The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline (i.e., non-pressurized installation allows for the selection of flowmeters without a ball valve).
   A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
   For situations that require continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added, which means selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
   A hole with a diameter of 50 should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.

 

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 


  The requirements for the straight pipe sections are 5D upstream and 3D downstream, which ensures the proper use of the electromagnetic flowmeter and meets the accuracy requirements.

  The measurement principle of the electromagnetic flowmeter does not depend on the characteristics of the flow.
If there is a certain amount of turbulence and vortices generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), it will not affect the measurement.

   However, if there are steady-state vortices in the measurement area, it will affect the stability and accuracy of the measurement.
 In this case, some measures should be taken to stabilize the flow distribution:

  1. Increase the length of the straight pipe sections upstream and downstream.
  2. Use a flow stabilizer.
  3. Reduce the cross-section of the measurement point.
 
  1. Requirements for the external environment
    1. The flowmeter should avoid installation in areas with significant temperature fluctuations or where it is subjected to high-temperature radiation from equipment. If installation is necessary, insulation and ventilation measures must be taken.
    2. The flowmeter is best installed indoors. If it must be installed outdoors, it should be protected from rain, flooding, and direct sunlight, with moisture-proof and sun-proof measures in place.
    3. The flowmeter should avoid installation in environments containing corrosive gases. If installation is necessary, ventilation measures must be implemented.
    4. To facilitate installation, maintenance, and upkeep, there should be ample installation space around the flowmeter.
    5. The installation site of the flowmeter should avoid magnetic fields and strong vibration sources. If there is significant vibration in the pipeline, supports should be provided on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type electromagnetic flowmeter

2.1. Requirements for straight sections To mitigate the effects of vortices and flow field distortion, there are specific requirements for the lengths of the straight pipe sections upstream and downstream of the flowmeter; otherwise, measurement accuracy will be affected (a straightener can also be installed, and it is advisable to avoid installation close to control valves and partially open valves).

2.2. Requirements for the process pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should be the same as that of the sensor and must meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for bypass pipes To facilitate the maintenance of the flowmeter, it is best to install a bypass pipe for the flowmeter. Additionally, for heavily contaminated fluids and situations where the flowmeter needs to be cleaned without stopping the fluid, a bypass pipe must be installed. a. To facilitate the maintenance of the flowmeter. b. Must be installed for heavily contaminated fluids. c. The fluid cannot be stopped while the flowmeter needs cleaning.

3. Installation requirements for insertion-type electromagnetic flowmeters

3.1. Requirements for straight pipe sections Inlet/outlet straight pipe sections: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN.

3.2. Requirements for grounding points To ensure reliable operation of the instrument and improve measurement accuracy, it should not be affected by external parasitic potentials. The sensor should have good grounding, with a grounding resistance of less than 10. (If the metal pipeline is well grounded, a dedicated grounding device is not required.)

3.3. Requirements for installation position as shown in the diagram.




COMPANY AND FACTORY PICTURE:

Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
Our Advantages
 
Zydc High Accuracy Flowmeter for Consistent Fluid Measurement



Team Building

We believe that the best team always wins!
 
Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
Exhibition pictures

We are actively seeking international cooperation through global exhibitions.
 
Zydc High Accuracy Flowmeter for Consistent Fluid Measurement
FAQ
 
1, What kind of product do you supply?

O
ur product
includes
pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow
meter.

2,What is your product and technology advantages?

Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in
China.
our technology closely
keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

O
ur factory located in Zibo, Shandong province, China, which is top
three
instrument production area.
A
nd take an area of more than 18000 square meters.

4, Can we visit your factory?

Y
ou are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

O
ur product warranty is 12 months from the shipping date, but we provide
lifetime
maintenance.

6, What are your payment terms?

Now
, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union,
PayPal
and trade assurance online payment.

7, What kind of certification do you have?

W
e have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate
a
nd
several
invention patents.

8, How long is your delivery date?

F
or peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

Our products quality enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

Y
ou can send inquiry through our email or cellphone as below:







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now