Product Overview
The ZZYS30 Vortex Flowmeter is a versatile and highly efficient velocity flow instrument designed to cater to a wide spectrum of applications.
Perfectly suited for measuring, monitoring, and controlling the flow of liquids, steam, and most gases, it ensures precision in various environments.
Engineered with a novel structure, it excels in resistance to mechanical vibrations, impacts, and contaminants, ensuring longevity and reliability.
Incorporating a design with no moving parts, the ZZYS30 eliminates wear and tear, requires no mechanical maintenance, offers low pressure loss, and delivers consistently stable performance with high accuracy.
User-friendly and easy to install, with customizable sensor and signal converter configurations to meet specific needs.
Product Features:
Extensive application range, ideal for accurately measuring the flow of steam, gas, and liquid.
Outstanding vibration performance with zero drift at zero point, effectively neutralizing the impact of external vibrations.
The ZZY30 provides integrated temperature and pressure options, significantly reducing installation costs for users.
Flexible output options: (0-5) kHz frequency output, (4-20) mA output, and compatibility with HART communication or Modbus protocol communication.
Supports parameter setting via Bluetooth communication, ensuring wear and dirt resistance, minimal maintenance, extended service life, and explosion-proof safety features.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100
Flange Connection Type Caliber Selection: 100, 150, 200
Flow Measurement Range: Normal flow velocity range with Reynolds number 1.5×104~4×106; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas flow measurement range: see Table 2.
Steam flow range: see Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC, High Temperature: -25ºC~150ºC, -25ºC~250ºC Output Signal: Pulse voltage output signal, High level: 8~10V, Low level: 0.7~1.3V Pulse duty cycle is about 50%, transmission distance is 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, transmission distance up to 1000m. Instrument Use Environment: Temperature -25ºC~+55ºC, Humidity 5~90% RH50ºC, Material: Stainless steel, aluminum alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level IP65
PACKING & SHIPPING
We ensure that your order will be delivered promptly at the earliest date you specify, meeting your requirements with precision and timeliness.Installation Requirements
Piping Condition
For optimal performance, the installation of the High Performance Vortex Flowmeter for Steam with Low Pressure Loss from Shandong Zhongziyi Intelligent Technology Co., Ltd. requires a specific length of straight pipe sections before and after the sensor. The typical configurations are as follows (D represents the pipe diameter):
1.
Install the sensor on horizontal, vertical, or inclined pipes (with liquid flowing upwards) that match the sensor's diameter. Ensure straight pipe sections of 15-20D upstream and 5-10D downstream of the sensor.
2.
Ensure the pipe near the sensor is fully filled with the liquid being measured.
3.
Avoid installing the sensor on pipes with strong mechanical vibrations.
4.
The inner diameter of straight pipe sections should match the sensor diameter as closely as possible. If a larger diameter pipe is necessary, the deviation should be ≤3% and not exceed 5mm. Do not install the sensor in areas with strong electromagnetic interference, limited space, or inconvenient maintenance access..
5.
Horizontal pipeline installation is most common. For gas flows containing small amounts of liquid, place the sensor at a higher point in the pipeline. For liquid flows containing small amounts of gas, install the sensor at a lower point in the pipeline.
6.
For vertical pipelines, install the sensor without flow direction restrictions for gas. If the gas contains liquid, flow should be from bottom to top. For liquid flows, ensure the flow is from bottom to top to avoid additional weight on the probe.
7.
Sensors can be side-mounted on horizontal pipelines for any fluid, especially superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier when feasible.
8.
Inverted sensor installation on horizontal pipelines is generally not recommended. It is unsuitable for most gases or superheated steam but can be used for saturated steam or high-temperature liquids requiring frequent pipeline cleaning.
9.
When measuring high-temperature steam, ensure the insulation layer on the pipeline does not exceed one-third of the bracket height.
10.
For pressure and temperature measurements, locate the pressure measurement point 3-5D downstream of the sensor and the temperature measurement point 6-8D downstream.