Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications

Product Details
Customization: Available
After-sales Service: 24/7 After Sales Services
Warranty: 12 Months From Delivery
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
  • Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZZYS30
Accuracy
>±1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 50.00cm
Package Gross Weight
5.000kg

Product Description

Product Description

Product Overview

The ZZYS30 Vortex Flowmeter by Shandong Zhongziyi Intelligent Technology Co., Ltd. is a cutting-edge velocity flow instrument designed for a multitude of applications.
Perfectly suited for accurate measurement, monitoring, and control of liquids, steam, and a broad spectrum of gases.
Engineered with an advanced structure that offers exceptional resistance to mechanical vibrations, impacts, and contaminants.
Featuring a design with no moving parts—ensuring zero wear and tear, eliminating the need for mechanical maintenance, providing low-pressure loss, stable performance, and unmatched accuracy.
The flowmeter is user-friendly with easy installation, and the flexibility to match the sensor and signal converter as needed.


Product Features:

Versatile application range, ideal for measuring steam, gases, and liquids.
Outstanding vibration resistance with zero-point stability, effectively neutralizing external vibrations.
The ZZY30 offers integrated temperature and pressure options, optimizing and reducing installation costs for users.
Supports various outputs: (0-5) kHz frequency, (4-20) mA, and HART/Modbus protocol for seamless communication.
Enhanced with Bluetooth communication for easy parameter settings. Durable and dirt-resistant, requiring no mechanical maintenance, ensuring a long service life, and explosion-proof for added safety.

Detailed Photos

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Product Parameters

Technical Index

Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100
Flange Connection Type Caliber Selection: 100, 150, 200
Flow Measurement Range: Normal Measurement Flow Velocity Range - Reynolds Number 1.5×10~4×10; Gas: 5~50 m/s; Liquid: 0.5~7 m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: See Table 2.
Steam Flow Range: See Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºCOutput Signal: Pulse Voltage Output Signal - High Level: 8~10V, Low Level: 0.7~1.3V; Pulse Duty Cycle: ~50%, Transmission Distance: 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance: 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC; Humidity: 5~90% RH50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)

Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028

Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8

Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630


Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660

Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure

Certifications

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications

Packing & Shipping

We will ensure the prompt delivery of your order, adhering to your specified schedule to meet your needs at the earliest possible date.
Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Installation Instructions

Key Installation Requirements

Optimal Piping Conditions
For optimal performance, the installation of the Easy Install Vortex Flowmeter requires specific straight pipe sections before and after the sensor. The common scenarios are as follows (D refers to the diameter of the pipe):

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D

1.
Install the sensor on a horizontal, vertical, or inclined pipe (with the liquid flowing bottom to top) that matches the sensor's diameter. Ensure a straight pipe section upstream of 15-20D and downstream of 5-10D.
2.
The pipe near the liquid sensor must be filled with the liquid being measured.
3.
Avoid installing the sensor on pipes experiencing strong mechanical vibrations.
4.
The inner diameter of the straight pipe should closely match the sensor's diameter. If not, use a slightly larger diameter pipe with an error of ≤3% and not exceeding 5mm. Avoid installing the sensor in areas with strong electromagnetic interference, confined spaces, or where maintenance is difficult..
5.
Horizontal pipeline installation is standard. For gas flow with minor liquid content, install the sensor at a higher pipeline position. For liquid flow with minor gas content, install the sensor at a lower pipeline position.
6.
Vertical pipeline installation. For gas flow, the sensor can be installed on a vertical pipeline regardless of flow direction. If the gas contains a small amount of liquid, the flow should be from bottom to top. For liquid flow, it should also be from bottom to top to prevent additional weight on the probe.
7.
Side installation on horizontal pipelines is viable for all fluids, including superheated steam, saturated steam, and low-temperature liquids. Side mounting is preferred when possible as it reduces temperature impacts on the amplifier.
8.
Inverted installation on horizontal pipelines is generally discouraged. It is unsuitable for general gases or superheated steam but can be used for saturated steam and high-temperature liquids or in situations requiring frequent cleaning.
9.
When measuring high-temperature steam, ensure the insulation layer does not exceed one-third of the bracket height.
10.
For pressure and temperature measurements near the sensor, place the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream.

Company Profile

Shandong Zhongziyi Intelligent Technology Co., Ltd.
Situated in the prestigious Zibo Science and Technology Industrial Park,
our facility spans an expansive area of over 18,000 square meters.
Boasting a state-of-the-art manufacturing factory,
we are wholeheartedly committed to
the research and development,
manufacturing,
sales, and service of cutting-edge pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we have achieved ISO9001 quality management system certification and are recognized as a high-tech enterprise within Shandong Province.
We are the premier close partner of Rosemount in China, ensuring our technology remains at the forefront through continuous collaboration.
With nearly six decades of in-depth engagement in instrument R&D and production,
we have amassed substantial technological expertise and unparalleled customer service experience.
Our products are extensively utilized across various sectors including Petroleum, Chemical Industry, Papermaking,
Metallurgy,
Medicine,
Food,
Power and Machinery, among others. Our sales network spans nationwide and internationally, earning the deep trust and favorable feedback from a wide array of users.
The cornerstone of our company is the principle of 'quality first, customer first.'
We warmly welcome customers to visit our factory and discuss potential cooperation.

COMPANY AND FACTORY PICTURES:

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Our Advantages

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Outstanding Features:
  1. Crafted with a simple yet resilient structure, our flowmeter boasts no moving parts, ensuring unparalleled reliability and durability.Its operation is consistently dependable.
  1. With a design that promotes easy installation and hassle-free maintenance, you can save valuable time and resources.
  1. The detection sensor is ingeniously designed to avoid direct contact with the measured medium, guaranteeing stable performance and extending the lifespan of the device.
  1. Delivering a pulse signal directly proportional to the flow rate, our flowmeter ensures no zero drift and exceptionally high accuracy.
  1. Featuring a wide measurement range,the flowmeter's range spans from1:50.
  1. Experience minimal pressure loss and reduced operating costs, resulting in significant energy savings. The output signal frequency remains unaffected by changes in the fluid's physical properties and composition within a certain range of Reynolds numbers. The meter coefficient is solely determined by the shape and size of the vortex shedding body, eliminating the need for volume flow compensation. Typically,recalibration of the meter coefficient is unnecessary even after component changes.


Building a Strong Team

We believe that the best team always wins!

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
Exhibition Highlights

We are fervently pursuing international cooperation through our active participation in global exhibitions.

Easy Install Vortex Flowmeter for Liquid, Gas, and Steam Applications
FAQ

1. What kind of product do you supply?

O
ur product
includes
pressure transmitters, temperature transmitters, level transmitters, pressure gauges, temperature gauges, and flow
meters.

2. What are your product and technology advantages?

Our factory, established in 1966, boasts nearly 60 years of manufacturing and R&D expertise. We are a highly esteemed partner of Rosemount in
China.
Our technology closely
aligns with Rosemount, and our remote pressure transmitter technology is particularly renowned for its stability, ranking No. 1 in China.

3. Where is your factory located?

O
ur factory is located in Zibo, Shandong province, China, one of the top
three
instrument production areas.
A
nd it spans over 18,000 square meters.

4. Can we visit your factory?

Y
ou are always welcome to visit our factory at any time convenient for you.

5. What is the warranty of your product?

O
ur product warranty is 12 months from the shipping date, but we also offer
lifetime
maintenance.

6. What are your payment terms?

Currently
, we accept a 50% down payment with the remaining 50% payable 5 days before delivery via T/T, Western Union,
PayPal,
and trade assurance online payment.

7. What kind of certification do you have?

W
e hold ISO9001, CCC, CNAS laboratory accreditation, Flame-proof certification, intrinsic safety certification, SIL certificate, ECM certificate, and Russia EAC and PAC certificates,
a
s well as
several
invention patents.

8. How long is your delivery date?

D
elivery time during peak season is 4 weeks, and 2 weeks during the off-season. Regardless of the season, we strive to meet your requirements.

9. How are your after-sales services?

Our products enjoy an excellent reputation for quality, with negligible warranty issues. However, we provide 24/7 online
support for any installation, commissioning, operation, or other inquiries.

10. How can I send an inquiry?

Y
ou can send your inquiry via email or cellphone as listed below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now