Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING: Experience our meticulous packing and reliable shipping solutions designed to ensure your products arrive safely and on time, every time.
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. Our team prioritizes promptness and reliability, guaranteeing that your experience with us is seamless and satisfying.The installation of the High Precision Electromagnetic Flowmeter with 4-20mA from Shandong Zhongziyi Intelligent Technology Co., Ltd. varies based on site pipeline conditions. For pipelines without a ball valve, select a flowmeter suitable for non-pressurized installation.
A hole with a diameter of 50mm should be made in the pipeline, followed by welding a connecting pipe to this opening.
For applications requiring continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added. This necessitates choosing an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a diameter of 50mm should be made in the pipeline, followed by welding a connecting pipe to this opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
Ensure the straight pipe sections are 5D upstream and 3D downstream. This setup guarantees optimal performance and measurement accuracy of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of the flow's characteristics.
If turbulence and vortices are generated in the pipeline's non-measurement area (e.g., elbows, tangential throttling, partially open shut-off valves), they will not affect the measurement accuracy.
However, steady-state vortices in the measurement area can compromise stability and accuracy.
To counteract this, implement measures to stabilize flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Straight Section Requirements To reduce vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. If these lengths are not met, measurement accuracy will suffer (a straightener can be installed, and installation near control valves or partially open valves should be avoided).
2.2. Process Pipes Requirements The flowmeter has specific requirements for the upstream and downstream process pipes at the installation site. Failure to meet these can affect measurement accuracy. a. The inner diameter of the upstream and downstream process pipes must match the sensor's inner diameter (0.98DN ≤ D ≤ 1.05DN, where DN is the sensor's inner diameter and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance, installing a bypass pipe for the flowmeter is highly recommended. This is crucial for systems dealing with heavily contaminated fluids or requiring flowmeter cleaning without halting fluid flow. a. Bypass pipes facilitate easy maintenance of the flowmeter. b. Mandatory installation for heavily contaminated fluids. c. Essential for cleaning the flowmeter without stopping fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections For optimal performance, ensure the following straight pipe sections: Inlet pipe should be at least 10 times the Pipe Diameter (≥ 10×DN). Outlet pipe should be at least 5 times the Pipe Diameter (≥ 5×DN).
3.2. Requirements for Grounding Points Reliable instrument operation and accurate measurements demand robust grounding to avoid external parasitic potentials. The sensor must have excellent grounding, maintaining a resistance of less than 10 ohms. (If the metal pipeline has sufficient grounding, an additional dedicated grounding device is unnecessary.)
3.3. Requirements for Installation Position Please refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: