Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
Discover the ZZYS30 Vortex Flowmeter, a versatile velocity flow instrument designed for a broad spectrum of applications.
Ideal for measuring, monitoring, and controlling the flow of liquids, steam, and a wide array of gases.
Boasting an innovative structure that withstands mechanical vibrations, impacts, and contamination effectively.
Featuring no moving parts, eliminating wear and tear, requiring no mechanical maintenance, ensuring low pressure loss, delivering stable performance, and providing high accuracy.
Effortless to install, with customizable sensor and signal converter configurations based on specific needs.
Product features:
Exceptionally versatile, suitable for measuring the flow of steam, gas, and liquid.
Superior vibration performance with zero drift at zero point, minimizing the impact of external vibrations.
The ZZY30 offers integrated temperature and pressure options, significantly reducing installation costs for users.
Provides (0-5) kHz frequency output, (4-20) mA output, and supports HART communication or Modbus protocol communication.
Enables parameter setting via Bluetooth communication. Built to be wear-resistant and dirt-resistant, requires no mechanical maintenance, ensures a long service life, and is explosion-proof for enhanced safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Available in sizes 25, 32, 50, 80, 100.
Flange Connection Type: Caliber selection available in sizes 100, 150, 200.
Flow Measurement Range: Normal measurement flow velocity range with Reynolds number 1.5×104~4×106; For gas: 5~50 m/s; For liquid: 0.5~7 m/s.
Normal Measurement Flow Range: For liquid,
Gas flow measurement range: Refer to Table 2.
Steam flow measurement range: Refer to Table 3.
Measurement Accuracy: Available in 1.0 class and 1.5 class.
Measured Medium Temperature:
Room temperature: -25ºC to 100ºC; High temperature: -25ºC to 150ºC and up to -25ºC to 250ºC. Output Signal: Pulse voltage output signal, high level 8~10V, low level 0.7~1.3V. Pulse duty cycle is approximately 50%, with a transmission distance of 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, with a transmission distance of 1000m. Instrument Use Environment: Temperature range from -25ºC to +55ºC; Humidity: 5%~90% RH at 50ºC. Material: Stainless steel, aluminum alloy.
Power Supply: DC 24V or a 3.6V lithium battery.
Explosion-Proof Grade: Intrinsically safe iaIIbT3-T6, protection level IP65.
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We will deliver your order at the earliest possible date, tailored precisely to your requirements.Installation Requirements
Piping Condition
The installation of the vortex flowmeter necessitates a specific straight pipe section both upstream and downstream. The typical configurations are as follows (D represents the pipe diameter):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
The sensor must be mounted on a horizontal, vertical, or inclined pipe (where liquid flows from bottom to top) with the same diameter as the sensor. Ensure a straight pipe length of 15-20D upstream and 5-10D downstream for optimal performance.
2.
The pipe surrounding the liquid sensor must be completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes that experience strong mechanical vibrations.
4.
The inner diameter of the straight pipe section should match the sensor diameter as closely as possible. If not, use a slightly larger pipe with an error margin of ≤3% and not exceeding 5mm. Avoid installation in areas with strong electromagnetic interference, constrained space, or challenging maintenance conditions. Installation requirements.
5.
Horizontal pipeline installation is the most common method for flow sensors. For gas flow measurements containing small amounts of liquid, place the sensor at a higher point in the pipeline. For liquid flow measurements containing small amounts of gas, place the sensor at a lower point in the pipeline.
6.
Vertical pipeline sensor installation. For gas flow measurements, the sensor can be installed on a vertical pipeline with no flow direction restriction. If gas contains liquid, position the flow from bottom to top. For liquid flow measurements, position the liquid flow from bottom to top to minimize additional weight on the probe.
7.
Side installation of sensors on horizontal pipelines. Side mounting is viable for all fluids, including superheated steam, saturated steam, and low-temperature liquids. When conditions permit, side mounting is preferred to reduce temperature impact on the amplifier.
8.
Inverted sensor installation on horizontal pipelines is generally inadvisable. It is unsuitable for general gases or superheated steam but can measure saturated steam and high-temperature liquids or situations necessitating frequent pipeline cleaning.
9.
When measuring high-temperature steam, the insulation layer around the sensor should not exceed one-third of the bracket height.
10.
Pressure and temperature measurement point selection. When both measurements are needed near the sensor, position the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream.