Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest possible date, meticulously adhering to your specified requirements. Our dedicated team ensures timely and efficient service, guaranteeing your satisfaction.The installation of the High Precision Electromagnetic Flowmeter from Shandong Zhongziyi Intelligent Technology Co., Ltd., varies depending on site pipeline conditions. Flowmeters without a ball valve should be installed on non-pressurized pipelines, allowing for the selection of such flowmeters without the need for a ball valve.
Create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to the opening, ensuring a secure and effective installation.
For applications requiring continuous flow during loading/unloading or where media overflow is unacceptable, incorporate a ball valve by selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
Form a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe at the opening, ensuring stability and precision.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To meet accuracy requirements and ensure proper use of the flowmeter, maintain straight pipe sections of 5D upstream and 3D downstream.
The measurement principle of our electromagnetic flowmeter is independent of flow characteristics, ensuring reliable performance.
Even with turbulence or vortices in the non-measurement area (e.g., elbows, tangential throttling, or partially open shut-off valves upstream), measurement accuracy remains unaffected.
However, steady-state vortices within the measurement area can impact stability and accuracy, demanding corrective measures.
Implement the following measures to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To counteract vortices and flow field distortion, follow specific length requirements for upstream and downstream straight pipe sections. Alternatively, use a straightener and avoid installations near control valves and partially open valves.
2.2. Requirements for Process Pipes There are specific requirements for the upstream and downstream process pipes at the installation point to ensure measurement accuracy: a. The inner diameters of the upstream and downstream process pipes must match the sensor's inner diameter, adhering to 0.98DN ≤ D ≤ 1.05DN. b. The process pipe and sensor must be concentric with an axial deviation not exceeding 0.05DN.
2.3. Requirements for bypass pipes To ensure seamless maintenance and optimal performance of the flowmeter, installing a bypass pipe is highly recommended. In scenarios involving heavily contaminated fluids or when the flowmeter requires cleaning without halting fluid flow, a bypass pipe is essential. a. Eases the maintenance process for the flowmeter. b. Crucial for handling heavily contaminated fluids. c. Enables cleaning of the flowmeter without interrupting fluid flow.
3. Installation requirements for insertion-type electromagnetic flowmeters To guarantee the accurate and reliable performance of our High Precision Electromagnetic Flowmeter, specific installation requirements must be followed.
3.1. Requirements for straight pipe sections For proper function and measurement accuracy, ensure the following straight pipe sections: Inlet: Minimum length should be ≥ 10×DN; Outlet: Minimum length should be ≥ 5×DN.
3.2. Requirements for grounding points To ensure the precise and reliable operation of the instrument, it is imperative to have robust grounding that minimizes the influence of external parasitic potentials. The sensor must have excellent grounding with a resistance of less than 10 ohms. (If the metal pipeline is already well-grounded, a dedicated grounding device may not be necessary.)
3.3. Requirements for installation position The installation position should be strictly in accordance with the provided diagram to ensure optimal performance.
COMPANY AND FACTORY PICTURE: Discover the state-of-the-art facilities and cutting-edge technology at Shandong Zhongziyi Intelligent Technology Co., Ltd. Our modern factory is equipped to produce the highest quality High Precision Electromagnetic Flowmeters, promising exceptional performance and reliability.