Customization: | Available |
---|---|
Type: | Remote Pressure Transmitter |
Structure Type: | Diffused Silicon Pressure Transmitter |
Still deciding? Get samples of US$ 730/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Range code |
GP Gauge pressure (Kpa ) | ||
Measuring range | Overload limit | Rated pressure(Max) | |
03 | -6~6 | 2000 | Flange rated pressure and the minimum value of the upper limit of the measuring range |
04 | -40~40 | 5000 | |
05 | -100~100 | 7000 | |
06 | -100~400 | 10000 | |
07 | -100~4000 | 10000 | |
08 | -100~10000 | 10000 |
Range code | DP Differential pressure (Kpa) | ||||
Range | Measuring range | Unilateral overpressure | Bilateral static pressure | Rated pressure (Max) | |
03 | 6 | -6~6 | 2000 | 16000 | The lower value of remote flange rated pressure and bilateral static |
04 | 40 | -40~40 | 5000 | 25000 | |
05 | 100 | -100~100 | 7000 | 25000 | |
06 | 400 | -400~400 | 10000 | 25000 | |
07 | 4000 | -500~4000 | 10000 | 25000 | |
08 | 10000 | -500~10000 | 10000 | 25000 |
Type | Code | Explanation | ||||
ZY8000Y | ZY8000Y | Intelligent remote transmitter | ||||
Remote system type | A | Pressure (T type)/single flange straight vertical installation | ||||
B | Differential pressure/single flange straight vertical installation | |||||
C | Differential pressure/single flange single flange straight side installation | |||||
D | D/P/high pressure straight side installation, low pressure side remote sealing system | |||||
E | Differential pressure /dual remote sealing system | |||||
Measuring range | 03 | -6~6 | ||||
04 | -40~40 | |||||
05 | -100~100 | |||||
06 | -100~400 | |||||
07 | -100~4000 | |||||
08 | -100~10000 | |||||
Communication protocol | H | HART protocol | ||||
P | PROFIBUS-PA(3.02)Field bus | |||||
F | Communication FF(6.1.1)Field bus communication | |||||
Process connection | o | Splint with 1/4NPT taper piping internal thread | ||||
1 | Freedom flange 1/2NPT taper piping internal thread | |||||
2 | T type thread joint M20×1.5,with rear weldingФ14 impulse pipe ball and cone joint | |||||
3 | 1/4NPTtaper pipe external thread convert to M20×1.5 joint,with rear weldingФ14impulse pipe | |||||
Isolation diaphragm | S | 316L | ||||
C | HC-276 | |||||
M | Monel | |||||
T | Tantalum | |||||
Sensor oil filling | 1 | Silicon oil(-50~205ºC) | ||||
2 | Fluorocarbon oil(-50~150ºC) | |||||
Housing | Material | Electrical interface | ||||
A | Aluminum | 1/2NPT internal thread,2 electrical joint | ||||
B | Aluminum | M20×1.5 internal thread,2 electrical joint | ||||
C | Stainless steel | 1/2NPT internal thread,2 electrical joint | ||||
D | Stainless steel | M20×1.5 internal thread,2 electrical joint | ||||
Display head | M0 | Without display head | ||||
M5 | LCD display head | |||||
Mounting bracket | Type | Material | ||||
B0 | Without bracket | |||||
B2 | B3 bracket | Q235 | ||||
B3 | B3 bracket | 304 | ||||
B4 | L Type bracket | 304 | ||||
Ex-proof | 0 | Non-Explosion-proof | ||||
d | PCEC: Flame-proof Ex dIIC T6 Gb | |||||
i | CLEx:Intrinsic safety Ex iaIIC T6 Ga | |||||
Flange type | FFW | Flush flange seal(2-in/DN50 3-in/DN80 4-in/DN100 RF) | ||||
RFW | Split flange seal(1/2-in/DN15 1-in/DN25 1_1/2-in/DN40 RF) | |||||
EFW | Extend insert flange seal | |||||
FCW | Flush flange seal -RTJ washer surface(2-in/3-in) | |||||
Flange standard | 1 | ANSI/ASME B16.5/HG20615 | ||||
2 | EN1092-1/GOST12815-80/HG20592 | |||||
Flange dimension | HG20615 | HG20592 | ||||
A | ¾-in | DN10 | ||||
B | 1-in | DN25 | ||||
C | 1½-in | DN40 | ||||
D | 2-in | DN50 | ||||
E | 3-in | DN80 | ||||
F | 4-in | DN100 | ||||
Flange pressure grade | HG20615 | HG20592 | ||||
2 | 150 psi | PN40 | ||||
4 | 300 psi | PN100 | ||||
6 | 600 psi | N/A | ||||
Flange sealing type | RF | RF surface | ||||
RJ | RJ Ring joint surface | |||||
M | M Male surface | |||||
FM | FM Female surface | |||||
Remote filling liquid | Sealed liquid | Contact liquid temperature | ||||
E | DC200 Silicon oil | -40ºC~205ºC | ||||
G | DC704 High temperature silicon oil | -10ºC~300ºC | ||||
I | Fluorocarbon oil | -50ºC~150ºC | ||||
Capillary protection coating material | B | 304 Bellows | ||||
C | 316 Bellows | |||||
D | 304 Bellows + PVC Coating | |||||
E | 316 Bellows +PVC Coating | |||||
Capillary length | - | The first and second is the length of H side:00m-15m The third and fourth is the length of L side:00m-15m |
||||
Flange material | A | CS | ||||
B | 304 | |||||
C | 316 | |||||
D | 316L | |||||
H side diaphragm insert cylinder length | - | H0=0mm(Flush flange selection) H1=50mm H2=100mm H3=150mm H4=200mm H5=250mm HX: customized dimension |
||||
L side diaphragm insert cylinder length |
- | L0=0mm(Flush flange selection) L1=50mm L2=100mm L3=150mm L4=200mm L5=250mm LX: customized dimension |
||||
Flange isolation diaphragm material | S | 316L | ||||
C | HC-276 | |||||
M | Monel | |||||
T | Tantalum | |||||
V | 316 Gold plating | |||||
P | 316L+PTFE | |||||
Insert cylinder | 0 | Without insert cylinder | ||||
1 | 316L | |||||
2 | HC-276 | |||||
3 | Monel | |||||
Additional option | / | Refer to additional selection list (as follow) | ||||
Project | Code | Explanation | ||||
Additional accreditation | P10 | SIL | ||||
Flushing ring | Thread | Material | ||||
G30X | 1/4 NPT+Plug | X:1 means 1 flush hole 2 means 2 flush hole |
304 | |||
G31X | 1/4 NPT+ Plug | 316 | ||||
G32X | 1/2 NPT+ Plug | 304 | ||||
G33X | 1/2 NPT+ Plug | 316 | ||||
Electrical joint | Specification and Dimension | Material | ||||
G60 | M20×1.5 Electrical joint + one plug | PA | ||||
G61 | 1/2NPT Electrical joint + one plug | PA | ||||
G70 | M20×1.5 Ex-proof Electrical joint+1 plug | 304 | ||||
G71 | 1/2NPT Ex-proof Electrical joint+1 plug | 304 |
Range code |
GP Gauge pressure (Kpa ) | ||
Measuring range | Overload limit | Rated pressure(Max) | |
03 | -6~6 | 2000 | Flange rated pressure and the minimum value of the upper limit of the measuring range |
04 | -40~40 | 5000 | |
05 | -100~100 | 7000 | |
06 | -100~400 | 10000 | |
07 | -100~4000 | 10000 | |
08 | -100~10000 | 10000 |
Range code | DP Differential pressure (Kpa) | ||||
Range | Measuring range | Unilateral overpressure | Bilateral static pressure | Rated pressure (Max) | |
03 | 6 | -6~6 | 2000 | 16000 | The lower value of remote flange rated pressure and bilateral static |
04 | 40 | -40~40 | 5000 | 25000 | |
05 | 100 | -100~100 | 7000 | 25000 | |
06 | 400 | -400~400 | 10000 | 25000 | |
07 | 4000 | -500~4000 | 10000 | 25000 | |
08 | 10000 | -500~10000 | 10000 | 25000 |
Type | Code | Explanation | ||||
ZY8000Y | ZY8000Y | Intelligent remote transmitter | ||||
Remote system type | A | Pressure (T type)/single flange straight vertical installation | ||||
B | Differential pressure/single flange straight vertical installation | |||||
C | Differential pressure/single flange single flange straight side installation | |||||
D | D/P/high pressure straight side installation, low pressure side remote sealing system | |||||
E | Differential pressure /dual remote sealing system | |||||
Measuring range | 03 | -6~6 | ||||
04 | -40~40 | |||||
05 | -100~100 | |||||
06 | -100~400 | |||||
07 | -100~4000 | |||||
08 | -100~10000 | |||||
Communication protocol | H | HART protocol | ||||
P | PROFIBUS-PA(3.02)Field bus | |||||
F | Communication FF(6.1.1)Field bus communication | |||||
Process connection | o | Splint with 1/4NPT taper piping internal thread | ||||
1 | Freedom flange 1/2NPT taper piping internal thread | |||||
2 | T type thread joint M20×1.5,with rear weldingФ14 impulse pipe ball and cone joint | |||||
3 | 1/4NPTtaper pipe external thread convert to M20×1.5 joint,with rear weldingФ14impulse pipe | |||||
Isolation diaphragm | S | 316L | ||||
C | HC-276 | |||||
M | Monel | |||||
T | Tantalum | |||||
Sensor oil filling | 1 | Silicon oil(-50~205ºC) | ||||
2 | Fluorocarbon oil(-50~150ºC) | |||||
Housing | Material | Electrical interface | ||||
A | Aluminum | 1/2NPT internal thread,2 electrical joint | ||||
B | Aluminum | M20×1.5 internal thread,2 electrical joint | ||||
C | Stainless steel | 1/2NPT internal thread,2 electrical joint | ||||
D | Stainless steel | M20×1.5 internal thread,2 electrical joint | ||||
Display head | M0 | Without display head | ||||
M5 | LCD display head | |||||
Mounting bracket | Type | Material | ||||
B0 | Without bracket | |||||
B2 | B3 bracket | Q235 | ||||
B3 | B3 bracket | 304 | ||||
B4 | L Type bracket | 304 | ||||
Ex-proof | 0 | Non-Explosion-proof | ||||
d | PCEC: Flame-proof Ex dIIC T6 Gb | |||||
i | CLEx:Intrinsic safety Ex iaIIC T6 Ga | |||||
Flange type | FFW | Flush flange seal(2-in/DN50 3-in/DN80 4-in/DN100 RF) | ||||
RFW | Split flange seal(1/2-in/DN15 1-in/DN25 1_1/2-in/DN40 RF) | |||||
EFW | Extend insert flange seal | |||||
FCW | Flush flange seal -RTJ washer surface(2-in/3-in) | |||||
Flange standard | 1 | ANSI/ASME B16.5/HG20615 | ||||
2 | EN1092-1/GOST12815-80/HG20592 | |||||
Flange dimension | HG20615 | HG20592 | ||||
A | ¾-in | DN10 | ||||
B | 1-in | DN25 | ||||
C | 1½-in | DN40 | ||||
D | 2-in | DN50 | ||||
E | 3-in | DN80 | ||||
F | 4-in | DN100 | ||||
Flange pressure grade | HG20615 | HG20592 | ||||
2 | 150 psi | PN40 | ||||
4 | 300 psi | PN100 | ||||
6 | 600 psi | N/A | ||||
Flange sealing type | RF | RF surface | ||||
RJ | RJ Ring joint surface | |||||
M | M Male surface | |||||
FM | FM Female surface | |||||
Remote filling liquid | Sealed liquid | Contact liquid temperature | ||||
E | DC200 Silicon oil | -40ºC~205ºC | ||||
G | DC704 High temperature silicon oil | -10ºC~300ºC | ||||
I | Fluorocarbon oil | -50ºC~150ºC | ||||
Capillary protection coating material | B | 304 Bellows | ||||
C | 316 Bellows | |||||
D | 304 Bellows + PVC Coating | |||||
E | 316 Bellows +PVC Coating | |||||
Capillary length | - | The first and second is the length of H side:00m-15m The third and fourth is the length of L side:00m-15m |
||||
Flange material | A | CS | ||||
B | 304 | |||||
C | 316 | |||||
D | 316L | |||||
H side diaphragm insert cylinder length | - | H0=0mm(Flush flange selection) H1=50mm H2=100mm H3=150mm H4=200mm H5=250mm HX: customized dimension |
||||
L side diaphragm insert cylinder length |
- | L0=0mm(Flush flange selection) L1=50mm L2=100mm L3=150mm L4=200mm L5=250mm LX: customized dimension |
||||
Flange isolation diaphragm material | S | 316L | ||||
C | HC-276 | |||||
M | Monel | |||||
T | Tantalum | |||||
V | 316 Gold plating | |||||
P | 316L+PTFE | |||||
Insert cylinder | 0 | Without insert cylinder | ||||
1 | 316L | |||||
2 | HC-276 | |||||
3 | Monel | |||||
Additional option | / | Refer to additional selection list (as follow) | ||||
Project | Code | Explanation | ||||
Additional accreditation | P10 | SIL | ||||
Flushing ring | Thread | Material | ||||
G30X | 1/4 NPT+Plug | X:1 means 1 flush hole 2 means 2 flush hole |
304 | |||
G31X | 1/4 NPT+ Plug | 316 | ||||
G32X | 1/2 NPT+ Plug | 304 | ||||
G33X | 1/2 NPT+ Plug | 316 | ||||
Electrical joint | Specification and Dimension | Material | ||||
G60 | M20×1.5 Electrical joint + one plug | PA | ||||
G61 | 1/2NPT Electrical joint + one plug | PA | ||||
G70 | M20×1.5 Ex-proof Electrical joint+1 plug | 304 | ||||
G71 | 1/2NPT Ex-proof Electrical joint+1 plug | 304 |