Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The ZZYS30 vortex flowmeter from Shandong Zhongziyi Intelligent Technology Co., Ltd. is a state-of-the-art velocity flow instrument designed for extensive applications.
Ideal for accurately measuring, monitoring, and controlling the flow of liquids, steam, and various gases, it stands out in versatility.
Engineered with a robust new structure, it excels in resistance to mechanical vibrations, impacts, and contamination.
With its innovative design having no moving parts, it ensures no wear and tear, eliminates the need for mechanical maintenance, offers low pressure loss, and delivers consistently stable and precise performance.
Installation is effortless, and the sensor and signal converter are adaptable to match specific requirements.
Product Features:
Extremely versatile, the ZZYS30 is perfect for measuring the flow of steam, gas, and liquid across various industrial applications.
Boasts remarkable vibration resistance, ensuring zero drift at zero points and effectively nullifying external vibration impacts.
Offers integrated temperature and pressure measurement options, greatly reducing installation costs for users.
Supports multiple output signals including (0-5) kHz frequency, (4-20) mA, and HART/Modbus protocol communication.
Features Bluetooth communication for easy parameter setting, and is wear-resistant, dirt-resistant, maintenance-free, has a long service life, and explosion-proof for enhanced safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Available in 25, 32, 50, 80, 100 mm
Flange Connection Type: Caliber Selection includes 100, 150, 200 mm
Flow Measurement Range: Normal measurement flow velocity range - Reynolds number 1.5×10^4~4×10^6; Gas: 5~50 m/s; Liquid: 0.5~7 m/s
Normal Measurement Flow Range: Liquid
Gas Flow Measurement Range: Refer to Table 2
Steam Flow Range: Refer to Table 3
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC, High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle is about 50%, transmission distance is 100m
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance is 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH at 50ºC. Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65
PACKING & SHIPPING
We will deliver your order product at the earliest date as required by you to ensure timely and efficient service.Essential Installation Prerequisites
Optimal Piping Conditions
To ensure optimal performance of the Easy Install Vortex Flowmeter for High Temperature Gas and Liquid, certain straight pipe sections are required before and after installation. The typical scenarios are outlined below (D represents the diameter of the pipe):
1.
Position the sensor on a horizontal, vertical, or inclined pipe (with upward liquid flow) matching the sensor's diameter. Ensure a straight pipe length of 15-20D upstream and 5-10D downstream.
2.
Ensure the pipe near the sensor is completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes with significant mechanical vibrations.
4.
The inner diameter of the straight pipe should closely match the sensor's diameter. If not feasible, a slightly larger diameter (within ≤3% and not more than 5mm) is acceptable. Avoid areas with strong electromagnetic interference, restricted space, or challenging maintenance conditions..
5.
For gas with minimal liquid content, install the sensor at the highest point on a horizontal pipeline. For liquid with minimal gas content, position the sensor at the lowest point on the pipeline.
6.
For vertical pipelines, install the sensor without flow direction constraints. Gas flow containing liquid should move from bottom to top. For liquid flow, ensure upward direction to prevent additional probe weight.
7.
Side-mount sensors on horizontal pipelines are ideal for superheated steam, saturated steam, and low-temperature liquids. Side installation limits temperature impacts on the amplifier.
8.
Inverted sensor installations on horizontal pipelines are generally inadvisable, except for saturated steam or high-temperature liquids where frequent cleaning is required.
9.
For high-temperature steam, the insulation layer should not exceed one-third of the bracket height.
10.
When pressure and temperature measurements are necessary, position the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream of the sensor.