Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 268/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
  • Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYZZ
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN200
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection Type
Flange, Thread, Clamping
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67
Range Down
10:1
Electrical Interface
M20×1.5 Special Can Be Customized
Power Supply
3.6V Lithium Battery, 24VDC
Float Material
304 or 316 L, PTFE or P.F.a
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 20.00cm
Package Gross Weight
3.000kg

Product Description

Product Description
 
Production Overview

The ZYZZ series metal tube float flowmeter, an epitome of precision engineering, employs a sophisticated variable area measurement principle
to deliver continuous, reliable measurement of volumetric flow rates for both liquids and gases within closed pipelines.
These metal tube float flowmeters are distinguished by their robust, dependable construction,
offering an expansive operating temperature range, exceptional accuracy, and cost-efficiency,
rendering them ideal for a multitude of flow measurement scenarios.

Features:
Product Features

Cutting-edge geomagnetic compensation for enhanced accuracy.
A diverse array of indicator formats to suit various needs.
Robust software capabilities for superior performance.
Dual indication system for enhanced operational clarity.
Sophisticated self-damping indicators for stable readings.
Innovative measuring tube and magnetic coupling design.
A scientifically designed lead interface for seamless integration.
Unmatched anti-interference performance ensuring reliable data.
Easily connected opto-isolated output for streamlined installation.
Comprehensive installation options and a variety of power supply choices ensure adaptability.

The metal rotor flowmeter is a staple in industrial and laboratory settings. It is renowned for its straightforward design, user-friendly operation, minimal pressure drop, and ease of maintenance. The rotor flowmeter excels in measuring minute flow rates in pipes with a diameter of D.< 150 mm, and it can also measure the flow of corrosive media. When in use, the flowmeter must be installed in a vertical section of the pipe, with the fluid medium flowing from the bottom to the top through the rotor flowmeter.
Detailed Photos
 
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Product Parameters
 
Technical parameters: Get ready to be impressed with the extraordinary technical prowess of our Clamping Connection Reliable Flowmeter, meticulously designed to excel in harsh environments. Featuring the advanced HART Protocol, this flowmeter guarantees seamless and accurate data communication, ensuring precision and reliability in every application.
Technical parameters
Measuring range Water: 20~100000L/h Air:0.3~3000Nm /h
Refer to the flow meter
Range down 10:1(DN≤100mm) 5:1 (DN≤100mm)
Accuracy Standard Class 1.5 Special class 1.0
Pressure class (DN15, N25, D40, D50) 0~4.0MPa
(DN80, DN100, DN150)0~1.6MPa
Medium temperature Ordinary: -40ºC~100ºC High temperature:-80ºC~250ºC
Lining PTFE:-40ºC~
Ambient temperature Pointer type: -40ºC~+65ºC
Intelligent type: -25ºC~+65ºC
Connection type Flange, Thread, Clamping
Electrical interface M20×1.5 special can be customized
Protection grade IP67
Ex-proof class Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473
Medium viscosity DN15≤5Mpa.s (DN25~150)≤5Mpa.s
Power supply 3.6V lithium battery, 24VDC
Measuring pipe material 304, 316L, 304 or 316L, PTFE or F46
Float material 304 or 316L;PTFE or PFA
 
Flow sheet Float material: 1, Cr Ni steel 2, PTFE
Caliber Float No. Flow range H2O Flow range air Press loss Kpa
1 CrNiSteel PTFE 1 CrNiSteel  
DN15 F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 10 1/h
15 1/h
20 1/h
25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 I /h
160 1/h
200 I /h
220 I /h
250 I /h
280 I /h
300 I /h
350 I /h
400 1/h
450 1/h
500 1/h
600 1/h
700I/h
800 1/h
9001/h 1000 1/h



25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 1/h
160 1/h
200 1/h
220 1/h
250 1/h
280 1/h
300 1/h
350 1/h
400 1/h
0.30 Nm³/h
0.45 Nm³/h
0.60 Nm³/h
0.75 Nm³/h
0.90 Nm³/h
1.05 Nm³/h
1.20 Nm³/h
1.35 Nm³/h
1.50 Nm³/h
1.65 Nm³/h
1.80 Nm³/h
2.10 Nm³/h
2.40 Nm³/h
2.70 Nm³/h
3.00 Nm³/h
3.60 Nm³/h
4.80 Nm³/h
6.00 Nm³/h
6.60 Nm³/h
7.50 Nm³/h
8.40 Nm³/h
9.00 Nm³/h
10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³
1.5
 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5






D25
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7
F25.8 F25.9 F25.10 F25.11
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h 30.0 Nm³/h
36.0 Nm³/h
48.0 Nm³/h
60.0 Nm³/h
75.0 Nm³/h
90.0Nm³/h 105.0 Nm³/h
120.0 Nm³/h
135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³
1.5
1.5
3.0
3.0
3.5
3.5
8.0
8.0
8.0
16.0
16.0
16.0




D50
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h 3.0
3.0
4.0
4.0
4.0
8.0
8.0
16.0
16.0


D65
F65.0 F65.1 F65.2 F65.3 F65.4 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h 12000l/h 16000l/h 20000l/h 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/  



D80
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h 25000 I /h 30000 I /h 35000 I /h 40000 I /h 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h 14.0
14.0
14.0
22.0
22.0
25.0
25.0



D100
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h 50000l/h 60000 l/h 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h 30.0
30.0
30.0
30.0
40.0
40.0

D125
F125.0 F125.1 F125.2 100000 l/h 125000 l/h 150000 l/h 100000 l/h 125000 l/h 3000.0Nm³/h 3800.00 Nm³/h 45.0
45.0
48.0
 
Product selection
ZYZZ          A           B          C          D          E          F
Model   structure   wetting material   additional structure     caliber     medium       indicator
ZYZZ Metal pipe floating flowmeter


Standard is
A
Measuring pipe structure, A
A Down in, up out
B Up in, down out
C Side in, side out
D Bottom in, side out
E Right in, left out
F Left in, right out
G Clamp
H Thread connection



Standard is R1
Wetting material B Special consult with factory
R1 1Cr18Ni9Ti,304
RO 0cr18Ni12M02Ti,316
RL 316L
RP PTFE
Ni HC 276
Ti Titanium


Standard is N
Additonal structure C  
N No
Z Damping
J Clamping
G High temperature
L High pressure
Caliber DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200

Medium
Medium type E
L Liquid
G Gas


Standard is 5
M1  
M2  
M3  
M4  
M5  
  Power supply mode
Default A J Local indication no power supply
A 24V DC Two wire power supply 4-20 mA output
B Battery, field LCD display,no signal output
C 100VAC-240VAC 50HZ-60HZ,output 4-20mA

Default L
 Display
L With LCD
  X Without LCD


Defult N
Alarm selection
N No alarm
K1 Upper limit alarm
K2 Lower limit alarm
K3 UP and lower limit alarm


Default D
Ex-proof sign
N No
D Flame-proof ExdIICT6
I Intrinsic safety EX(ia)IICT6


Default N
N No communication protocol
H Hart protocol
M Modbus protocol
P PROfibus-PA field bus
Model selection example:ZYZZ/A/R1/M5/DN25
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol
 

 
Certifications
 
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to delivering your Good Repeatability Flowmeter, designed with High Accuracy and available in Threaded Mounting Options. Crafted to your exact specifications, our pledge is to provide unparalleled service excellence. We prioritize punctuality and efficiency in our delivery process, ensuring your requirements are met with precision and reliability.
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Installation Instructions
 
Installation:

The metal rotor flowmeter, a premier variable area flow measuring tool, excels in precision by monitoring the float position with exceptional accuracy.

This exemplary device boasts an all-metal architecture and embraces a modular design philosophy. Its compact nature, minimal pressure loss, and impressive range ratio (10:1) distinguish it as an industry leader.
Its intuitive design allows for effortless installation and maintenance, making it the go-to choice across diverse industries, even in the most complex and severe environments.
Perfect for managing flow and process control of small flow rates and low velocities, it thrives under challenging medium conditions.

For seamless and optimal operation, the correct installation of the metal rotor flowmeter is vital. Consider the following installation guidelines:

(1) Ensure vertical installation with fluid flow directed from bottom to top. Maintain a straight pipe length of five times the instrument's diameter at both entry and exit points. For new setups, ensure thorough pipeline flushing prior to flowmeter installation.

(2) Position a valve upstream and a flow control valve 5 to 10 times the instrument diameter downstream. For smaller diameters, place a filter upstream. Should magnetic materials be present in the medium, install a magnetic filter ahead of the flowmeter.

(3) Enhance maintenance efficiency by connecting a bypass pipeline during instrument installation, allowing for easy flowmeter servicing or replacement.

(4) In the event of a dirty medium, promptly clean both pipes and float to maintain optimal operation.

(5) With a general measurement accuracy level of 1.5, if your application demands greater precision, consider alternatives to the metal tube rotor flowmeter.

Company and factory photos
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Our Advantages
 
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments


Innovative Team Building

We firmly believe that a winning team is built on a foundation of excellence, collaboration, and unwavering dedication. Our commitment to fostering a culture of teamwork and innovation empowers us to drive success and deliver exceptional results.
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
Exhibition Highlights

We are dynamically pursuing international partnerships by prominently featuring our cutting-edge innovations at esteemed global exhibitions. This strategic approach amplifies our reach and showcases our commitment to advancing technology on a worldwide scale.
Clamping Connection Reliable Flowmeter with Hart Protocol for Harsh Environments
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now