Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
Our unwavering commitment is to ensure that your ordered product is delivered swiftly and precisely as per your requirements. We guarantee timely and efficient service to meet all your needs.The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline. This allows for the selection of flowmeters without a ball valve, simplifying the installation process.
Create a 50mm diameter hole in the pipeline, and prepare to weld a connecting pipe to the opening. This step ensures a secure and stable installation of the flowmeter.
For scenarios requiring continuous flow during loading and unloading, or where media overflow is prohibited, a ball valve must be integrated. This necessitates choosing an insertion-type electromagnetic flowmeter with a ball valve structure for optimal performance.
Create a 50mm diameter hole in the pipeline, and prepare to weld a connecting pipe to the opening. This guarantees a precise and reliable connection.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The requirements for the straight pipe sections are 5D upstream and 3D downstream. This ensures the proper use and high accuracy of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics, making it versatile for various applications.
If turbulence and vortices are generated in non-measurement areas of the pipeline (such as near elbows, tangential throttling, or partially open valves upstream), the measurement remains unaffected.
However, steady-state vortices in the measurement area can compromise stability and accuracy.
In such cases, implementing measures to stabilize the flow distribution is essential:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Straight Section Requirements To mitigate the effects of vortices and flow field distortions, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. Installing a flow straightener and avoiding proximity to control valves or partially open valves is advisable.
2.2. Process Pipe Requirements The flowmeter has specific needs for the upstream and downstream process pipes at the installation point to ensure accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor's diameter, satisfying the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. Ensure the process pipe and sensor are concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. This is particularly crucial for heavily contaminated fluids and scenarios where the flowmeter requires cleaning without interrupting the fluid flow. The following points underline the necessity: a. Facilitates the consistent maintenance of the flowmeter. b. Mandatory for handling heavily contaminated fluids. c. Ensures fluid flow continues unimpeded during cleaning operations of the flowmeter.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections To optimize performance, the straight pipe sections before and after the flowmeter are crucial. The inlet straight pipe section should be at least 10 times the diameter of the pipe (≥ 10×DN), while the outlet straight pipe section should be at least 5 times the diameter of the pipe (≥ 5×DN).
3.2. Requirements for Grounding Points For reliable operation and to enhance measurement accuracy, the instrument must be shielded from external parasitic potentials through proper grounding. The sensor should be well-grounded, maintaining a resistance of less than 10 ohms. If the metal pipeline is already well-grounded, a dedicated grounding device is unnecessary.
3.3. Requirements for Installation Position Refer to the accompanying diagram to ensure the correct installation position for optimal functionality.