Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 268/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
  • Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYZZ
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN200
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection Type
Flange, Thread, Clamping
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67
Range Down
10:1
Electrical Interface
M20×1.5 Special Can Be Customized
Power Supply
3.6V Lithium Battery, 24VDC
Float Material
304 or 316 L, PTFE or P.F.a
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 20.00cm
Package Gross Weight
3.000kg

Product Description

Product Description
 
Production Overview

The ZYZZ series metal tube float flowmeter epitomizes precision and excellence by employing a sophisticated variable area measurement principle.
It is ingeniously engineered for the uninterrupted measurement of volumetric flow rates of both liquids and gases within securely enclosed pipelines.
Metal tube float flowmeters stand out with their exceptionally robust and dependable construction.
They boast a wide operating temperature range, ensuring high accuracy and offering remarkable cost-effectiveness.
These attributes make them ideal for a wide array of flow measurement applications, providing unmatched versatility.

Features:
Product Features

Enhanced geomagnetic compensation that elevates measurement accuracy.
A diverse array of indicator forms tailored to fit varied needs.
Potent software capabilities for seamless operation.
A dual indication system that ensures precision in readouts.
Innovative self-damping indicators for stable and clear measurements.
A uniquely designed measuring tube paired with an advanced magnetic coupling structure.
Meticulously crafted scientific lead interface for optimum performance.
Superior anti-interference performance ensuring reliable outputs.
Easily connectable opto-isolated output for enhanced data integrity.
Offers a comprehensive range of installation methods and a variety of power supply options to suit diverse requirements.

The metal rotor flowmeter is a staple in both industry and laboratory settings, known for its straightforward design, user-friendly operation, minimal pressure loss, and facile maintenance. Perfect for measuring small flow rates in pipelines with diameter D, it stands as a quintessential tool for precision flow measurement.< 150 mm, and it can also measure the flow of corrosive media. When in use, the flowmeter must be installed in a vertical section of the pipe, with the fluid medium flowing from the bottom to the top through the rotor flowmeter.
Detailed Photos
 
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Product Parameters
 
Technical Parameters: Delve into the cutting-edge specifications of our HART protocol flowmeter, renowned for its anti-interference capabilities and robust design, ensuring reliable performance across a multitude of applications.
Technical parameters
Measuring range Water: 20~100000L/h Air:0.3~3000Nm /h
Refer to the flow meter
Range down 10:1(DN≤100mm) 5:1 (DN≤100mm)
Accuracy Standard Class 1.5 Special class 1.0
Pressure class (DN15, N25, D40, D50) 0~4.0MPa
(DN80, DN100, DN150)0~1.6MPa
Medium temperature Ordinary: -40ºC~100ºC High temperature:-80ºC~250ºC
Lining PTFE:-40ºC~
Ambient temperature Pointer type: -40ºC~+65ºC
Intelligent type: -25ºC~+65ºC
Connection type Flange, Thread, Clamping
Electrical interface M20×1.5 special can be customized
Protection grade IP67
Ex-proof class Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473
Medium viscosity DN15≤5Mpa.s (DN25~150)≤5Mpa.s
Power supply 3.6V lithium battery, 24VDC
Measuring pipe material 304, 316L, 304 or 316L, PTFE or F46
Float material 304 or 316L;PTFE or PFA
 
Flow sheet Float material: 1, Cr Ni steel 2, PTFE
Caliber Float No. Flow range H2O Flow range air Press loss Kpa
1 CrNiSteel PTFE 1 CrNiSteel  
DN15 F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 10 1/h
15 1/h
20 1/h
25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 I /h
160 1/h
200 I /h
220 I /h
250 I /h
280 I /h
300 I /h
350 I /h
400 1/h
450 1/h
500 1/h
600 1/h
700I/h
800 1/h
9001/h 1000 1/h



25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 1/h
160 1/h
200 1/h
220 1/h
250 1/h
280 1/h
300 1/h
350 1/h
400 1/h
0.30 Nm³/h
0.45 Nm³/h
0.60 Nm³/h
0.75 Nm³/h
0.90 Nm³/h
1.05 Nm³/h
1.20 Nm³/h
1.35 Nm³/h
1.50 Nm³/h
1.65 Nm³/h
1.80 Nm³/h
2.10 Nm³/h
2.40 Nm³/h
2.70 Nm³/h
3.00 Nm³/h
3.60 Nm³/h
4.80 Nm³/h
6.00 Nm³/h
6.60 Nm³/h
7.50 Nm³/h
8.40 Nm³/h
9.00 Nm³/h
10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³
1.5
 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5






D25
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7
F25.8 F25.9 F25.10 F25.11
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h 30.0 Nm³/h
36.0 Nm³/h
48.0 Nm³/h
60.0 Nm³/h
75.0 Nm³/h
90.0Nm³/h 105.0 Nm³/h
120.0 Nm³/h
135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³
1.5
1.5
3.0
3.0
3.5
3.5
8.0
8.0
8.0
16.0
16.0
16.0




D50
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h 3.0
3.0
4.0
4.0
4.0
8.0
8.0
16.0
16.0


D65
F65.0 F65.1 F65.2 F65.3 F65.4 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h 12000l/h 16000l/h 20000l/h 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/  



D80
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h 25000 I /h 30000 I /h 35000 I /h 40000 I /h 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h 14.0
14.0
14.0
22.0
22.0
25.0
25.0



D100
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h 50000l/h 60000 l/h 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h 30.0
30.0
30.0
30.0
40.0
40.0

D125
F125.0 F125.1 F125.2 100000 l/h 125000 l/h 150000 l/h 100000 l/h 125000 l/h 3000.0Nm³/h 3800.00 Nm³/h 45.0
45.0
48.0
 
Product selection
ZYZZ          A           B          C          D          E          F
Model   structure   wetting material   additional structure     caliber     medium       indicator
ZYZZ Metal pipe floating flowmeter


Standard is
A
Measuring pipe structure, A
A Down in, up out
B Up in, down out
C Side in, side out
D Bottom in, side out
E Right in, left out
F Left in, right out
G Clamp
H Thread connection



Standard is R1
Wetting material B Special consult with factory
R1 1Cr18Ni9Ti,304
RO 0cr18Ni12M02Ti,316
RL 316L
RP PTFE
Ni HC 276
Ti Titanium


Standard is N
Additonal structure C  
N No
Z Damping
J Clamping
G High temperature
L High pressure
Caliber DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200

Medium
Medium type E
L Liquid
G Gas


Standard is 5
M1  
M2  
M3  
M4  
M5  
  Power supply mode
Default A J Local indication no power supply
A 24V DC Two wire power supply 4-20 mA output
B Battery, field LCD display,no signal output
C 100VAC-240VAC 50HZ-60HZ,output 4-20mA

Default L
 Display
L With LCD
  X Without LCD


Defult N
Alarm selection
N No alarm
K1 Upper limit alarm
K2 Lower limit alarm
K3 UP and lower limit alarm


Default D
Ex-proof sign
N No
D Flame-proof ExdIICT6
I Intrinsic safety EX(ia)IICT6


Default N
N No communication protocol
H Hart protocol
M Modbus protocol
P PROfibus-PA field bus
Model selection example:ZYZZ/A/R1/M5/DN25
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol
 

 
Certifications
 
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to exceeding your expectations with our Good Repeatability Flowmeter, known for its unparalleled High Accuracy and versatile Threaded Mounting Options. We promise to deliver this state-of-the-art product with precision and speed, finely tuned to your unique requirements. Our unwavering commitment to excellence ensures not only superior service but also timely and efficient delivery, meticulously crafted to meet and surpass your every need.
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Installation Instructions
 
Installation:

The metal rotor flowmeter is a sophisticated variable area flow metering instrument designed to capture precise measurements based on the position of the float.

This innovative device boasts an all-metal structure complemented by a modular design concept. Its compact size, alongside a low pressure drop and an impressive range ratio of 10:1,
makes it exceptionally easy to install and maintain. It stands out as a versatile solution across numerous industries, excelling even in the most complex and challenging environments.
Whether it's controlling flow and processes for small flow volumes, low velocities, or handling demanding media conditions, this flowmeter is engineered for optimal performance.

Proper and precise installation of the metal rotor flowmeter is crucial to ensure its smooth and effective operation. Key installation considerations include:

(1) The flowmeter must be installed in a vertical position, ensuring that the fluid flows upward from bottom to top. A straight pipe section, five times the instrument's diameter, is mandatory at the inlet and outlet. Before installation, new pipelines should be thoroughly flushed to prevent any obstructions.

(2) An upstream valve is essential, and it should be paired with a flow control valve 5 to 10 times the instrument's diameter downstream. Additionally, for smaller instruments, it is advisable to equip the upstream with a filter. Should the medium contain magnetic materials, implementing a magnetic filter before the flowmeter is necessary.

(3) To ease maintenance and facilitate easy replacement, it's recommended to include a bypass pipeline during the installation process.

(4) In scenarios where the medium is particularly dirty, regular cleaning of the pipes and float is essential to maintain functionality.

(5) The metal rotor flowmeter typically achieves a measurement accuracy of level 1.5. For applications demanding higher precision, selecting a different type of flowmeter is advisable.

Company and Factory Photos
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Our Advantages
 
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design


Innovative Team Building

We firmly believe that a winning team is forged through the pillars of excellence, seamless collaboration, and unwavering dedication! Each member's unique contribution propels us towards greatness.
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
Exhibition Highlights

We are passionately pursuing international partnerships, proudly showcasing our groundbreaking innovations and cutting-edge solutions at prestigious global exhibitions. Join us in our journey to redefine excellence!
Hart Protocol Flowmeter with Anti-Interference Features and Reliable Design
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now