Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
  • Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter, from Shandong Zhongziyi Intelligent Technology Co., Ltd., embodies state-of-the-art precision and reliability. Featuring a sensor and a converter, it harnesses the power of Faraday's electromagnetic induction law to deliver impeccable measurements of conductive fluids. This advanced flow meter has reached the pinnacle of national standards in excitation, lining, and intelligent technology, adhering to JB/T9248-2015 and JJG 1033-2007.

Features:

- Exhibits stable performance, remarkable repeatability, and extraordinary accuracy (up to 0.2%).
- Designed with no flow obstruction components, ensuring no pressure loss and minimal clogging.
- Exceptionally adaptable to highly corrosive and abrasive media.
- Facilitates operation without cover removal via mobile Bluetooth and infrared remote control.
- Employs stainless steel mesh technology, perfect for negative pressure environments.
- Supports GPRS and Bluetooth wireless transmission; seamlessly integrates with MODBUS and HART communication protocols.
- Utilizes a 16-bit embedded microprocessor, delivering rapid computations, high precision, and programmable low-frequency square wave excitation for enhanced stability and energy efficiency.
- Incorporates SMD components and surface mount technology (SMT) for superior circuit reliability. Allows online modification of measurement ranges to precisely match user data acquisition needs.
- Measurement results remain unaffected by fluid pressure, temperature, density, viscosity, or other physical parameters.
- Equipped with digital communication outputs like RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Features robust self-check, self-diagnosis, and alarm functionalities.
- Includes three internal accumulators displaying forward, reverse, and differential cumulative amounts. An internal clock records up to 16 power outage instances (optional).
- The ultra-low EMI switch power supply accommodates a wide voltage range with exceptional EMI resistance.
Detailed Photos
 
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Product Parameters
 
Technical Parameters: Discover the precise engineering behind the Thread Electromagnetic Flowmeter by Shandong Zhongziyi Intelligent Technology Co., Ltd. Our flowmeter is meticulously designed to offer unparalleled accuracy and reliability, even in the harshest environments. Engineered with anti-vibration and explosion-proof features, this innovative device ensures seamless performance and long-lasting durability, making it the ideal choice for a wide range of industrial applications.
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design

PACKING & SHIPPING

We are committed to delivering your ordered product promptly, meeting your specific requirements with utmost efficiency and reliability. Count on us for timely and exceptional service.
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Installation Instructions
 

The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. For flowmeters without a ball valve, they should be installed on a non-pressurized pipeline. This non-pressurized installation allows for the selection of flowmeters without a ball valve.
Ensure a precision opening with a diameter of 50 in the pipeline. Prepare to weld a connecting pipe securely to the opening in the pipeline to facilitate installation.
For situations demanding continuous flow during loading and unloading, or where media overflow is not permissible, integrating a ball valve is essential. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
Ensure a precision opening with a diameter of 50 in the pipeline. Prepare to weld a connecting pipe securely to the opening in the pipeline to facilitate installation.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

The optimal performance of the electromagnetic flowmeter requires straight pipe sections of 5D upstream and 3D downstream. This ensures accurate and reliable measurements.

The electromagnetic flowmeter's measurement principle remains unaffected by the flow characteristics, ensuring consistent precision.
Turbulence and vortices in non-measurement regions of the pipeline, such as elbows, tangential throttling, or partially open shut-off valves upstream, do not compromise measurement accuracy.

However, steady-state vortices within the measurement area can affect both stability and accuracy of the readings.
To counter such issues, consider the following measures to stabilize the flow distribution:

  1. 1. Increase the length of the straight pipe sections upstream and downstream to smoothen the flow.
  2. 2. Implement a flow stabilizer to maintain consistent flow rates.
  3. 3. Reduce the cross-section of the measurement point to regulate flow dynamics.
  1. Requirements for the External Environment
    1. Avoid installing the flowmeter in areas with significant temperature fluctuations or high-temperature radiation. If unavoidable, ensure proper insulation and adequate ventilation measures are in place.
    2. Ideal installation is indoors. If outdoor installation is necessary, protect the flowmeter from rain, flooding, and direct sunlight with moisture-proof and sun-proof measures.
    3. Avoid environments with corrosive gases. If necessary, ensure effective ventilation measures are implemented.
    4. Allow ample space around the flowmeter to facilitate easy installation, maintenance, and upkeep activities.
    5. Ensure the installation site is free from magnetic fields and strong vibration sources. If pipeline vibration is significant, provide supports on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type Electromagnetic Flowmeter

2.1. Requirements for Straight Sections To mitigate effects of vortices and flow field distortions, adhere to specific requirements for the lengths of straight pipe sections upstream and downstream of the flowmeter. For enhanced accuracy, it is advisable to install a flow straightener and avoid installation near control valves or partially open valves.

2.2. Requirements for Process Pipes For optimal accuracy, ensure the upstream and downstream process pipes conform to specific requirements at the installation point: a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter and meet the condition: 0.98DN ≤ D ≤ 1.05DN (DN is the sensor's inner diameter, D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes To ensure the seamless maintenance of our Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design, installing a bypass pipe is highly recommended. This is essential for scenarios involving heavily contaminated fluids or when cleaning the flowmeter without halting the fluid flow. Key considerations include: a. Facilitating maintenance of the flowmeter. b. Essential for managing heavily contaminated fluids. c. Allowing continuous fluid flow during flowmeter cleaning.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters

3.1. Requirements for Straight Pipe Sections To guarantee optimal performance, the straight pipe sections for the inlet and outlet are critical: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN.

3.2. Requirements for Grounding Points For superior operational reliability and enhanced measurement accuracy, the sensor must be insulated from external parasitic potentials. Ensure the sensor is properly grounded with a grounding resistance of less than 10 ohms. (If the metal pipeline is adequately grounded, an additional dedicated grounding device may not be necessary.)

3.3. Requirements for Installation Position Refer to the accompanying diagram for precise installation positioning.


COMPANY AND FACTORY PICTURE:

Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Our Advantages
 
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design


Team Building

We firmly believe that a unified and cohesive team is the cornerstone of unparalleled success!
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
Exhibition Pictures

We are vigorously pursuing international partnerships by participating in premier global exhibitions.
Thread Electromagnetic Flowmeter with Anti-Vibration and Explosion Proof Design
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now