Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we pledge to deliver your ANSI Electromagnetic Flowmeter with High Precision and Good Repeatability as swiftly as possible, adhering to your specific requirements. Our commitment ensures timely and efficient service for every order.The installation of the ANSI Electromagnetic Flowmeter with High Precision and Good Repeatability varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline, allowing for easy selection and installation of flowmeters without a ball valve.
A precise hole with a diameter of 50mm should be created in the pipeline. Then, prepare to weld a connecting pipe to this opening, ensuring a secure and reliable connection.
For scenarios requiring uninterrupted flow during loading and unloading, or where media spillage is not acceptable, a ball valve is essential. This necessitates the use of an insertion-type electromagnetic flowmeter equipped with a ball valve structure for optimal performance.
A precise hole with a diameter of 50mm should be created in the pipeline. Then, prepare to weld a connecting pipe to this opening, ensuring a secure and stable connection.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure the accurate operation of the electromagnetic flowmeter, the straight pipe sections must be 5D upstream and 3D downstream. This specification guarantees optimal performance and measurement accuracy.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics, ensuring consistent and reliable measurements regardless of flow behavior.
Even if turbulence and vortices are generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or partially open shut-off valves upstream), they will not affect the measurement accuracy.
However, steady-state vortices within the measurement area can impact both stability and accuracy. Therefore, it is critical to manage these factors carefully.
In such cases, take measures to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To minimize the effects of vortices and flow field distortion, adhere to specific requirements for the lengths of the straight pipe sections upstream and downstream of the flowmeter. Otherwise, measurement accuracy will be compromised. Consider installing a straightener and avoid proximity to control valves and partially open valves.
2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point to ensure measurement accuracy. a. The inner diameter of the upstream and downstream process pipes must match the sensor's inner diameter, meeting the condition: 0.98DN ≤ D ≤ 1.05DN (DN = inner diameter of the sensor, D = inner diameter of the process pipe). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN to maintain precision.
2.3. Requirements for bypass pipes To optimize the maintenance operations of the flowmeter, the installation of a bypass pipe is highly recommended. This setup is particularly essential for managing heavily contaminated fluids and allows for the cleaning of the flowmeter without interrupting the fluid flow. a. Essential for seamless maintenance of the flowmeter. b. Mandatory for handling heavily contaminated fluids. c. Enables cleaning of the flowmeter without fluid interruption.
3. Installation requirements for insertion-type electromagnetic flowmeters
3.1. Requirements for straight pipe sections Inlet/outlet straight pipe sections: To ensure accurate flow measurements, the inlet should be ≥ 10×DN and the outlet should be ≥ 5×DN.
3.2. Requirements for grounding points To secure the reliable operation of the instrument and enhance measurement precision, the sensor must be well-grounded to avoid interference from external parasitic potentials. The grounding resistance should be less than 10 ohms. (Note: If the metal pipeline is already well-grounded, a dedicated grounding device is not necessary.)
3.3. Requirements for installation position as shown in the diagram.