Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 268/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
  • Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYZZ
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN200
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection Type
Flange, Thread, Clamping
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67
Range Down
10:1
Electrical Interface
M20×1.5 Special Can Be Customized
Power Supply
3.6V Lithium Battery, 24VDC
Float Material
304 or 316 L, PTFE or P.F.a
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 20.00cm
Package Gross Weight
3.000kg

Product Description

Product Description
 
Production Overview

The impressive ZYZZ series metal tube float flowmeter embraces the innovative variable area measurement principle
for seamless and precise continuous measurement of volumetric flow rates for both liquids and gases within closed pipelines.
These metal tube float flowmeters boast a robust and incredibly reliable structure,
an extensive operating temperature range, high precision, and remarkable cost-efficiency,
rendering them exceptionally suitable for a multitude of flow measurement applications.

Features:
Product Features

Enjoy enhanced geomagnetic compensation for superior accuracy.
Experience a rich variety of indicator forms to suit diverse requirements.
Benefit from powerful software capabilities for increased performance.
Utilize a dual indication system for comprehensive data display.
Leverage advanced self-damping indicators for improved stability.
Discover a unique measuring tube and magnetic coupling structure for unmatched efficiency.
Incorporate a scientific lead interface for enhanced usability.
Enjoy superior anti-interference performance for accurate readings.
Benefit from a conveniently connected opto-isolated output for better integration.
Take advantage of a full range of installation methods and diverse power supply options for ultimate flexibility.

The metal rotor flowmeter stands as a cornerstone in both industrial and laboratory settings, celebrated for its simple yet efficient structure, intuitive operation, minimal pressure loss, and easy maintenance. Ideal for measuring small flow rates in pipes with a diameter of D.< 150 mm, and it can also measure the flow of corrosive media. When in use, the flowmeter must be installed in a vertical section of the pipe, with the fluid medium flowing from the bottom to the top through the rotor flowmeter.
Detailed Photos
 
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Product Parameters
 
Technical parameters:
Technical parameters
Measuring range Water: 20~100000L/h Air:0.3~3000Nm /h
Refer to the flow meter
Range down 10:1(DN≤100mm) 5:1 (DN≤100mm)
Accuracy Standard Class 1.5 Special class 1.0
Pressure class (DN15, N25, D40, D50) 0~4.0MPa
(DN80, DN100, DN150)0~1.6MPa
Medium temperature Ordinary: -40ºC~100ºC High temperature:-80ºC~250ºC
Lining PTFE:-40ºC~
Ambient temperature Pointer type: -40ºC~+65ºC
Intelligent type: -25ºC~+65ºC
Connection type Flange, Thread, Clamping
Electrical interface M20×1.5 special can be customized
Protection grade IP67
Ex-proof class Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473
Medium viscosity DN15≤5Mpa.s (DN25~150)≤5Mpa.s
Power supply 3.6V lithium battery, 24VDC
Measuring pipe material 304, 316L, 304 or 316L, PTFE or F46
Float material 304 or 316L;PTFE or PFA
 
Flow sheet Float material: 1, Cr Ni steel 2, PTFE
Caliber Float No. Flow range H2O Flow range air Press loss Kpa
1 CrNiSteel PTFE 1 CrNiSteel  
DN15 F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 10 1/h
15 1/h
20 1/h
25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 I /h
160 1/h
200 I /h
220 I /h
250 I /h
280 I /h
300 I /h
350 I /h
400 1/h
450 1/h
500 1/h
600 1/h
700I/h
800 1/h
9001/h 1000 1/h



25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 1/h
160 1/h
200 1/h
220 1/h
250 1/h
280 1/h
300 1/h
350 1/h
400 1/h
0.30 Nm³/h
0.45 Nm³/h
0.60 Nm³/h
0.75 Nm³/h
0.90 Nm³/h
1.05 Nm³/h
1.20 Nm³/h
1.35 Nm³/h
1.50 Nm³/h
1.65 Nm³/h
1.80 Nm³/h
2.10 Nm³/h
2.40 Nm³/h
2.70 Nm³/h
3.00 Nm³/h
3.60 Nm³/h
4.80 Nm³/h
6.00 Nm³/h
6.60 Nm³/h
7.50 Nm³/h
8.40 Nm³/h
9.00 Nm³/h
10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³
1.5
 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5






D25
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7
F25.8 F25.9 F25.10 F25.11
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h 30.0 Nm³/h
36.0 Nm³/h
48.0 Nm³/h
60.0 Nm³/h
75.0 Nm³/h
90.0Nm³/h 105.0 Nm³/h
120.0 Nm³/h
135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³
1.5
1.5
3.0
3.0
3.5
3.5
8.0
8.0
8.0
16.0
16.0
16.0




D50
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h 3.0
3.0
4.0
4.0
4.0
8.0
8.0
16.0
16.0


D65
F65.0 F65.1 F65.2 F65.3 F65.4 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h 12000l/h 16000l/h 20000l/h 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/  



D80
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h 25000 I /h 30000 I /h 35000 I /h 40000 I /h 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h 14.0
14.0
14.0
22.0
22.0
25.0
25.0



D100
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h 50000l/h 60000 l/h 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h 30.0
30.0
30.0
30.0
40.0
40.0

D125
F125.0 F125.1 F125.2 100000 l/h 125000 l/h 150000 l/h 100000 l/h 125000 l/h 3000.0Nm³/h 3800.00 Nm³/h 45.0
45.0
48.0
 
Product selection
ZYZZ          A           B          C          D          E          F
Model   structure   wetting material   additional structure     caliber     medium       indicator
ZYZZ Metal pipe floating flowmeter


Standard is
A
Measuring pipe structure, A
A Down in, up out
B Up in, down out
C Side in, side out
D Bottom in, side out
E Right in, left out
F Left in, right out
G Clamp
H Thread connection



Standard is R1
Wetting material B Special consult with factory
R1 1Cr18Ni9Ti,304
RO 0cr18Ni12M02Ti,316
RL 316L
RP PTFE
Ni HC 276
Ti Titanium


Standard is N
Additonal structure C  
N No
Z Damping
J Clamping
G High temperature
L High pressure
Caliber DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200

Medium
Medium type E
L Liquid
G Gas


Standard is 5
M1  
M2  
M3  
M4  
M5  
  Power supply mode
Default A J Local indication no power supply
A 24V DC Two wire power supply 4-20 mA output
B Battery, field LCD display,no signal output
C 100VAC-240VAC 50HZ-60HZ,output 4-20mA

Default L
 Display
L With LCD
  X Without LCD


Defult N
Alarm selection
N No alarm
K1 Upper limit alarm
K2 Lower limit alarm
K3 UP and lower limit alarm


Default D
Ex-proof sign
N No
D Flame-proof ExdIICT6
I Intrinsic safety EX(ia)IICT6


Default N
N No communication protocol
H Hart protocol
M Modbus protocol
P PROfibus-PA field bus
Model selection example:ZYZZ/A/R1/M5/DN25
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol
 

 
Certifications
 
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output

PACKING & SHIPPING: We take meticulous care in packaging your order, employing robust materials to safeguard your Good Repeatability Flowmeter during transit. Our shipping process is a seamlessly orchestrated operation, ensuring that your product arrives in pristine condition, swiftly and securely, right at your doorstep.

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are unwavering in our commitment to delivering your Good Repeatability Flowmeter with High Accuracy and Threaded Mounting Options. Precision-engineered to your exact specifications, we assure you of an unparalleled service experience, marked by efficient and timely delivery. Your satisfaction is our paramount goal, promising you a seamless transaction that meets your every need with top-tier service excellence.
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Installation Instructions
 
Installation:

The robust and reliable metal rotor flowmeter is an advanced variable area flow measuring instrument, ingeniously crafted to determine fluid flow by assessing the float position.

Distinguished by its all-metal structure and pioneering modular design concept, this flowmeter is characterized by its compact size, minimal pressure loss, expansive range ratio of 10:1,
and the remarkable convenience it offers in installation and maintenance. These attributes make it an indispensable tool across various industries, adeptly performing even in challenging and rigorous environments.
It excels in the precise flow and process control of small flow rates, low velocities, and a variety of demanding medium conditions.

Ensuring the correct installation of the metal rotor flowmeter is crucial for achieving optimal operational performance. Important installation considerations include:

(1) The flowmeter must be positioned vertically, with the fluid to be measured entering from the bottom and exiting at the top. A straight pipe section measuring five times the instrument's diameter should be present at both the inlet and outlet. For newly installed pipelines, it is imperative to conduct a thorough flushing prior to the installation of the flowmeter.

(2) Install a valve upstream of the flowmeter and a flow control valve 5 to 10 times the instrument's diameter downstream. For instruments with smaller diameters, incorporate a filter upstream. If the medium being measured contains magnetic particles, it is essential to install a magnetic filter before the flowmeter.

(3) To enable easy maintenance and replacement, a bypass pipeline should be integrated during the instrument's installation.

(4) For media with significant impurities, prompt cleaning of the pipes and float is necessary to maintain efficiency.

(5) The standard measurement accuracy of the metal rotor flowmeter is typically at 1.5. For applications demanding higher precision, selecting a metal tube rotor flowmeter is not recommended.

Company and factory photos
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Our Advantages
 
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output


Innovative Team Building

We firmly believe that a winning team is built on excellence, collaboration, and dedication!
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
Exhibition Highlights

We are proactively pursuing international partnerships by showcasing our innovations at global exhibitions.
Solid Structure Rotor Flowmeter with Hart Protocol and 4-20mA Output
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now