Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
  • Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter, crafted by Shandong Zhongziyi Intelligent Technology Co., Ltd., comprises two core components: a sensor and a converter. Operating on Faraday's law of electromagnetic induction, it is designed to precisely measure conductive fluids. This high-precision flow meter has been meticulously upgraded to ensure high reliability and now stands at the forefront of excitation, lining, and intelligent technologies within the industry. Adhering to stringent standards such as JB/T9248-2015 and JJG 1033-2007, the ZYDC electromagnetic flow meter signifies excellence and innovation.

Features:

- Exhibits stable performance with exceptional repeatability and precision, achieving an accuracy of up to 0.2%.
- Designed without flow obstruction components, ensuring no pressure loss and minimal risk of clogging.
- Highly adaptable to environments with corrosive and abrasive media.
- Facilitates operation without opening the cover using mobile Bluetooth and infrared remote controls.
- Incorporates stainless steel mesh technology, making it suitable for use under negative pressure conditions.
- Supports GPRS and Bluetooth for wireless transmission and is compatible with communication protocols like MODBUS and HART.
- Features a 16-bit embedded microprocessor for rapid computation, high precision, and programmable low-frequency square wave excitation, enhancing measurement stability while maintaining low power consumption.
- Utilizes SMD components and surface mount technology (SMT), ensuring high circuit reliability. Allows for online modification of the measurement range to meet specific user needs, optimizing compatibility with data acquisition terminals.
- Measurement results remain unaffected by fluid pressure, temperature, density, viscosity, or other physical parameters.
- Provides digital communication signal outputs such as RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Equipped with self-check, self-diagnosis, and alarm functions for enhanced operational security.
- Includes three internal accumulators that separately display forward, reverse, and differential cumulative amounts. An internal clock records up to 16 power outage events (optional).
- The ultra-low EMI switch power supply is designed to handle wide power supply voltage variations and offers superior EMI resistance.
Detailed Photos
 
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Product Parameters
 
Technical parameters: Explore the advanced technical specifications of our IP67 Electromagnetic Flowmeter. Engineered with meticulous precision, this device ensures optimal performance and reliability with its robust 4-20mA output, making it the ideal choice for a wide range of industrial applications.
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement

PACKING & SHIPPING

We are dedicated to providing prompt and reliable delivery of your ordered product, tailored to meet your specific needs, with a focus on timely and efficient service.
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Installation Instructions
 

The installation of the IP67 Electromagnetic Flowmeter with High Reliability and 4-20mA Output by Shandong Zhongziyi Intelligent Technology Co., Ltd. varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on non-pressurized pipelines, as non-pressurized installation allows for the selection of flowmeters without a ball valve.
Create a hole with a diameter of 50 in the pipeline, and prepare to weld a connecting pipe to the opening in the pipeline.
For conditions requiring continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
Create a hole with a diameter of 50 in the pipeline, and prepare to weld a connecting pipe to the opening in the pipeline.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

Straight pipe sections should be 5D upstream and 3D downstream. This ensures proper use of the electromagnetic flowmeter and meets accuracy requirements.

The measurement principle of the electromagnetic flowmeter remains unaffected by flow characteristics.
If turbulence and vortices are generated in the non-measurement area of the pipeline (e.g., elbows, tangential throttling, or a partially open shut-off valve upstream), it will not impact the measurement.

However, steady-state vortices in the measurement area will affect measurement stability and accuracy.
In such cases, measures should be taken to stabilize the flow distribution:

  1. Increase the length of the straight pipe sections upstream and downstream.
  2. Use a flow stabilizer.
  3. Reduce the cross-section of the measurement point.
  1. Requirements for the external environment
    1. Avoid installing the flowmeter in areas with significant temperature fluctuations or subjected to high-temperature radiation from equipment. If installation is necessary, insulation and ventilation measures must be taken.
    2. The flowmeter should preferably be installed indoors. If outdoor installation is necessary, protect it from rain, flooding, and direct sunlight, with moisture-proof and sun-proof measures in place.
    3. Avoid installing the flowmeter in environments containing corrosive gases. If installation is necessary, implement ventilation measures.
    4. Ensure ample installation space around the flowmeter to facilitate installation, maintenance, and upkeep.
    5. The installation site of the flowmeter should avoid magnetic fields and strong vibration sources. If there is significant vibration in the pipeline, supports should be provided on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type Electromagnetic Flowmeter

2.1. Requirements for straight sections To mitigate the effects of vortices and flow field distortion, specific lengths are required for the straight pipe sections upstream and downstream of the flowmeter; otherwise, measurement accuracy will be affected. Installing a straightener and avoiding installation close to control or partially open valves is advisable.

2.2. Requirements for the process pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should match that of the sensor and meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, installing a bypass pipe is highly recommended. For scenarios involving heavily contaminated fluids or when there's a need to clean the flowmeter without halting the fluid flow, a bypass pipe becomes essential. a. Facilitates easy maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Allows cleaning of the flowmeter without interrupting the fluid flow.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters

3.1. Requirements for Straight Pipe Sections For optimal performance, adhere to the following straight pipe section guidelines: Inlet section should be at least ≥ 10×DN; Outlet section should be at least ≥ 5×DN.

3.2. Requirements for Grounding Points To achieve reliable operation and enhanced measurement accuracy, it is vital to avoid interference from external parasitic potentials. The sensor must be properly grounded with a grounding resistance of less than 10 ohms. (Note: If the metal pipeline is already well-grounded, a dedicated grounding device may not be necessary.)

3.3. Requirements for Installation Position Refer to the provided diagram for precise installation positioning guidelines.


COMPANY AND FACTORY PICTURE:

Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Our Advantages
 
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement


Collaborative Team Building

We firmly believe that a winning team is built on exceptional collaboration and unity!
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
Exhibition Highlights

We are enthusiastically pursuing international partnerships by showcasing our products at global exhibitions.
Advanced IP67 Electromagnetic Flowmeter for Reliable Fluid Measurement
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now