Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment methods: | |
---|---|
Support payment in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are unwaveringly dedicated to expediting the delivery of your ordered product, adhering strictly to your specifications. Our mission is to guarantee prompt and efficient service, ensuring that your needs are met with the utmost urgency and care.The installation of the electromagnetic flowmeter from Shandong Zhongziyi Intelligent Technology Co., Ltd. is tailored to your specific pipeline conditions. For pipelines that are not pressurized, you have the flexibility to select flowmeters without a ball valve.
Create a hole with a diameter of 50mm in the pipeline and prepare to weld a connecting pipe to this opening, ensuring a secure and precise installation.
For applications requiring continuous flow during loading and unloading, or where media overflow is not permissible, an insertion-type electromagnetic flowmeter with a ball valve structure is essential.
Similarly, a 50mm diameter hole should be made in the pipeline, accompanied by the welding of a connecting pipe to the opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To maintain the highest accuracy of the electromagnetic flowmeter, ensure straight pipe sections of 5D upstream and 3D downstream.
The electromagnetic flowmeter's measurement principle is independent of flow characteristics, ensuring consistent and reliable readings.
Even in the presence of turbulence and vortices in non-measurement areas of the pipeline, such as near elbows or partially open valves, measurement accuracy remains unaffected.
However, steady-state vortices within the measurement area can compromise stability and accuracy, necessitating corrective measures.
In such cases, to ensure stabilized flow distribution, consider the following actions:
1.2. Pipeline-type electromagnetic flowmeter
2.1. Requirements for straight sections To ensure optimal performance, adhere to specific lengths for the straight pipe sections upstream and downstream of the flowmeter. Installing a straightener and avoiding proximity to control valves and partially open valves is advisable.
2.2. Requirements for the process pipes The flowmeter's accuracy depends on the upstream and downstream process pipes matching the sensor's inner diameter, within the range: 0.98DN ≤ D ≤ 1.05DN. Ensure the process pipe and sensor are concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for bypass pipes For seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. In scenarios involving heavily contaminated fluids or when the flowmeter requires cleaning without interrupting fluid flow, the installation of a bypass pipe becomes imperative. a. For streamlined maintenance of the flowmeter. b. Mandatory for managing heavily contaminated fluids. c. Ensures uninterrupted fluid flow during flowmeter cleaning.
3. Installation requirements for insertion-type electromagnetic flowmeters
3.1. Requirements for straight pipe sections Inlet/outlet straight pipe sections: The inlet should be at least ≥ 10×DN; The outlet should be at least ≥ 5×DN.
3.2. Requirements for grounding points To guarantee reliable operation and enhance measurement accuracy, the instrument must be shielded from external parasitic potentials. Ensure the sensor is well-grounded with a grounding resistance of less than 10. (If the metal pipeline has adequate grounding, a dedicated grounding device is not necessary.)
3.3. Requirements for installation position as shown in the diagram.
COMPANY AND FACTORY PICTURE: