Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest possible date, meticulously adhering to your specific requirements. Our unwavering dedication ensures timely and efficient service, providing you with peace of mind and unmatched reliability.The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. If the flowmeter lacks a ball valve, it should be installed on a non-pressurized pipeline, allowing for the selection of flowmeters without a ball valve.
A pipeline hole with a diameter of 50mm should be created, and preparations for welding a connecting pipe to the pipeline opening must be made.
For continuous flow during loading/unloading or where media overflow is not permitted, a ball valve must be added. Select an insertion-type electromagnetic flowmeter with a ball valve structure in such cases.
A pipeline hole with a diameter of 50mm should be created, and preparations for welding a connecting pipe to the pipeline opening must be made.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
Straight pipe sections must be 5D upstream and 3D downstream to ensure proper flowmeter use and meet accuracy requirements.
The measurement principle of the electromagnetic flowmeter is independent of flow characteristics.
Turbulence and vortices generated in the non-measurement area (e.g., elbows, tangential throttling, or a partially open shut-off valve upstream) will not affect the measurement.
However, steady-state vortices in the measurement area will affect measurement stability and accuracy.
To stabilize flow distribution, consider the following measures:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. Otherwise, measurement accuracy will suffer. A straightener can be installed, and it's advisable to avoid installing the flowmeter close to control or partially open valves.
2.2. Requirements for Process Pipes The flowmeter has specific requirements for upstream and downstream process pipes at the installation point. Otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter, meeting the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, the installation of a bypass pipe is highly recommended. This is especially crucial for handling heavily contaminated fluids and instances where cleaning the flowmeter without halting fluid flow is necessary. a. Essential for facilitating the maintenance of the flowmeter. b. Indispensable for managing heavily contaminated fluids. c. Enables cleaning without interrupting the fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: Ensure the inlet section is ≥ 10×DN and the outlet section is ≥ 5×DN for optimal performance.
3.2. Requirements for Grounding Points To guarantee reliable instrument operation and enhance measurement accuracy, the sensor must be well-grounded to prevent external parasitic potentials. Grounding resistance should be below 10. (If the metal pipeline is adequately grounded, a dedicated grounding device is unnecessary.)
3.3. Requirements for Installation Position Refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: