High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
  • High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter, a premier innovation by Shandong Zhongziyi Intelligent Technology Co., Ltd., is an amalgamation of a sensor and a converter, functioning seamlessly on Faraday's electromagnetic induction principle to accurately measure conductive fluids. This high-precision, highly reliable instrument has undergone continuous enhancements, achieving national leadership in excitation technology, lining technology, and intelligent operations. It adheres to stringent standards such as JB/T9248-2015 and JJG 1033-2007.

Features:

- Exhibits stable performance with exceptional repeatability and remarkable accuracy reaching up to 0.2%.
- Designed with no flow obstruction components, ensuring no pressure loss and minimizing clogging risks.
- Highly adaptable to corrosive and abrasive media, showcasing superior resilience.
- Facilitates operation without the need to open the cover, utilizing mobile Bluetooth and infrared remote control for convenience.
- Incorporates stainless steel mesh technology, making it effective for applications under negative pressure.
- Supports wireless transmissions via GPRS and Bluetooth, and is compatible with MODBUS and HART communication protocols.
- Features a 16-bit embedded microprocessor, ensuring swift computation, high accuracy, and a programmable low-frequency square wave excitation for enhanced flow measurement stability and reduced power consumption.
- Utilizes SMD components and surface mount technology (SMT) for high circuit reliability. It allows online adjustment of the measurement range according to user requirements, facilitating better integration with data acquisition terminals.
- Provides measurement results that are independent of fluid pressure, temperature, density, viscosity, and other physical parameters.
- Equipped with digital communication signal outputs including RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Incorporates self-check, self-diagnosis, and alarm functionalities for enhanced operational reliability.
- Features three internal accumulators to separately display forward, reverse, and differential cumulative amounts, with an internal clock to record up to 16 power outage events (optional).
- Boasts an ultra-low EMI switch power supply, accommodating a wide range of power supply voltage variations while offering strong EMI resistance for stable operations.
Detailed Photos
 
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
Product Parameters
 
Technical parameters: Our High Reliability Electromagnetic Flowmeter is engineered to meet ANSI Standards and boasts an impressive IP67 Rating, ensuring excellent performance and durability in diverse environments.
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we prioritize prompt and reliable delivery of your High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating. We are dedicated to meeting your specified timelines, ensuring that your products reach you swiftly and efficiently.
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
Installation Instructions
 

The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. For flowmeters without a ball valve, they should be installed on a non-pressurized pipeline, allowing for easy selection and installation of flowmeters without a ball valve.
A precise hole with a diameter of 50 should be made in the pipeline. Ensure that preparations are made to securely weld a connecting pipe to the opening in the pipeline.
In scenarios requiring continuous flow during loading and unloading, or where media overflow is non-permissible, a ball valve must be added. This necessitates selecting an insertion-type electromagnetic flowmeter equipped with a ball valve structure.
A precise hole with a diameter of 50 should be made in the pipeline. Ensure that preparations are made to securely weld a connecting pipe to the opening in the pipeline.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

The requirements for the straight pipe sections are 5D upstream and 3D downstream. This ensures the correct usage of the electromagnetic flowmeter and adherence to accuracy standards.

The measurement principle of the electromagnetic flowmeter remains consistent regardless of flow characteristics.
If there is turbulence or vortices generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), it will not affect the measurement.

However, steady-state vortices in the measurement area will impact the stability and accuracy of the measurement.
To stabilize the flow distribution, consider the following measures:

  1. Increase the length of the straight pipe sections upstream and downstream.
  2. Utilize a flow stabilizer.
  3. Reduce the cross-section of the measurement point.
  1. Requirements for the External Environment
    1. The flowmeter should avoid installation in areas with significant temperature fluctuations or exposure to high-temperature radiation from equipment. If installation is unavoidable, appropriate insulation and ventilation measures must be implemented.
    2. Ideally, the flowmeter should be installed indoors. If outdoor installation is necessary, it should be protected from rain, flooding, and direct sunlight, with effective moisture-proof and sun-proof measures in place.
    3. The flowmeter should avoid environments containing corrosive gases. If installation cannot be avoided, ensure proper ventilation measures are in place.
    4. To facilitate installation, maintenance, and upkeep, ensure ample installation space around the flowmeter.
    5. The installation site of the flowmeter should avoid magnetic fields and strong vibration sources. If pipeline vibration is significant, provide supports on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type Electromagnetic Flowmeter

2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. Otherwise, measurement accuracy will be compromised (a straightener can also be installed, and it is advisable to avoid installation near control valves and partially open valves).

2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter and meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes To ensure seamless maintenance and optimal performance of the flowmeter, we highly recommend the installation of bypass pipes. These bypass pipes are crucial for applications involving heavily contaminated fluids and scenarios where the flowmeter needs to be cleaned without halting the fluid flow. Key reasons for installing bypass pipes include: a. Facilitating easy maintenance of the flowmeter. b. Essential for managing heavily contaminated fluids. c. Allowing for cleaning of the flowmeter without stopping the fluid flow.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters

3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: To ensure accurate measurements, the inlet section should be at least 10 times the nominal diameter (10×DN) and the outlet section should be at least 5 times the nominal diameter (5×DN).

3.2. Requirements for Grounding Points For the reliable operation and enhanced measurement accuracy of the instrument, it is imperative that the system is not influenced by external parasitic potentials. The sensor must be well-grounded, with a grounding resistance of less than 10 ohms. If the metal pipeline is already well-grounded, a dedicated grounding device may not be necessary.

3.3. Requirements for Installation Position Please refer to the accompanying diagram for detailed installation position requirements.


COMPANY AND FACTORY PICTURE:

High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
Our Advantages
 
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating


Team Building

We believe that the best team always wins!
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
Exhibition pictures

We are actively seeking international cooperation through global exhibitions.
High Reliability Electromagnetic Flowmeter with ANSI Standards and IP67 Rating
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now