Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest possible date, precisely meeting your requirements. Our dedication guarantees timely and efficient service, so you can rely on us for prompt and dependable delivery.The installation of the High Accuracy Electromagnetic Flowmeter with Wireless and Easy Mounting from Shandong Zhongziyi Intelligent Technology Co., Ltd. depends on the specific conditions of the pipeline on site. For pipelines that are non-pressurized, flowmeters without a ball valve can be installed. This non-pressurized installation allows for the selection of flowmeters without a ball valve.
Begin by creating a hole with a diameter of 50 in the pipeline and prepare to weld a connecting pipe to this opening.
In scenarios where continuous flow during loading and unloading is required, or where media overflow is strictly prohibited, it is necessary to add a ball valve. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
As before, create a hole with a 50-diameter in the pipeline and prepare to weld a connecting pipe at the opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The installation requires straight pipe sections measuring 5D upstream and 3D downstream. This ensures the proper functioning of the electromagnetic flowmeter and meets the stringent accuracy requirements.
The measurement principle of our electromagnetic flowmeter remains consistent regardless of the flow characteristics.
If turbulence and vortices are present in the non-measurement areas of the pipeline, such as elbows, tangential throttles, or partially open valves upstream, the measurement process remains unaffected.
However, the presence of steady-state vortices within the measurement area will impact both stability and accuracy.
Consequently, measures should be taken to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortions, specific requirements must be met for the lengths of the straight pipe sections upstream and downstream of the flowmeter. Ignoring these requirements can compromise measurement accuracy. Alternatively, a straightener can be installed, and it is advisable to avoid installation near control valves and partially open valves.
2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point. Failure to meet these requirements can affect measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match that of the sensor, meeting the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, installing a bypass pipe is highly recommended. In scenarios involving heavily contaminated fluids or when the flowmeter requires cleaning without interrupting the fluid flow, a bypass pipe installation becomes imperative. a. Facilitates easy maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Enables cleaning of the flowmeter without halting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections For optimal performance, ensure the following straight pipe sections: Inlet straight pipe section should be at least ≥ 10×DN, while the outlet straight pipe section should be at least ≥ 5×DN.
3.2. Requirements for Grounding Points To guarantee the instrument's reliable operation and enhance measurement precision, it is crucial to mitigate the impact of external parasitic potentials. The flowmeter's sensor must be excellently grounded, achieving a grounding resistance of less than 10. (Note: If the metal pipeline is already well-grounded, a dedicated grounding device may not be necessary.)
3.3. Requirements for Installation Position Refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: