Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. Our dedication to promptness and reliability guarantees that your needs are met with the utmost precision and care.The installation of the electromagnetic flowmeter varies based on the site pipeline conditions. For non-pressurized pipelines, flowmeters without a ball valve can be used. Ensure that the pipeline is non-pressurized before choosing a flowmeter without a ball valve.
A hole with a 50mm diameter should be drilled in the pipeline. Prepare to weld a connecting pipe to this opening for proper installation.
For scenarios requiring continuous flow or where media overflow is unacceptable, incorporate a ball valve. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a 50mm diameter should be drilled in the pipeline. Prepare to weld a connecting pipe to this opening for proper installation.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
Ensure upstream and downstream straight pipe sections are 5D and 3D respectively for optimal performance and accuracy of the electromagnetic flowmeter.
The electromagnetic flowmeter's measurement principle is unaffected by flow characteristics.
Turbulence and vortices in non-measurement areas (like elbows or partially open valves upstream) do not impact measurement.
However, steady-state vortices in the measurement area will affect measurement stability and accuracy.
To stabilize flow distribution and ensure measurement precision, consider the following measures:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To reduce vortices and flow field distortion, specific lengths for upstream and downstream straight pipe sections are required. Alternatively, use a straightener and avoid proximity to control valves and partially open valves to maintain measurement accuracy.
2.2. Requirements for Process Pipes The flowmeter demands specific conditions for upstream and downstream process pipes to ensure accuracy. The inner diameters of these pipes should match the sensor's diameter and meet the condition: 0.98DN ≤ D ≤ 1.05DN, where DN is the sensor's inner diameter, and D is the process pipe's inner diameter. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of our high-accuracy flowmeter, installing a bypass pipe is highly recommended. This becomes essential for handling heavily contaminated fluids and scenarios where you need to clean the flowmeter without halting fluid flow. a. Streamlined maintenance of the flowmeter. b. Crucial for heavily contaminated fluids. c. Continuous fluid flow during flowmeter cleaning.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: Ensure optimal performance by having an inlet length of ≥ 10×DN and an outlet length of ≥ 5×DN.
3.2. Requirements for Grounding Points For reliable operation and enhanced measurement precision, the instrument must be shielded from external parasitic potentials. The sensor should be properly grounded, with resistance less than 10 ohms. (If the metal pipeline is already well grounded, a dedicated grounding device is not necessary.)
3.3. Requirements for Installation Position as Detailed in the Diagram.