The ZZYS30 Gas Vortex Flowmeter is a versatile velocity flow instrument designed for a multitude of applications.
Ideal for the accurate measurement, vigilant monitoring, and precise control of the flow of liquids, steam, and an array of gases.
Engineered with a robust new structure that excels in resisting mechanical vibrations, impacts, and contamination.
Boasting no moving parts, it ensures zero wear and tear, requires no mechanical maintenance, offers low pressure loss, delivers stable performance, and guarantees high accuracy.
Installation is a breeze, with the flexibility to match the sensor and signal converter as per the specific requirements.
Product Features:
Wide application range, perfect for measuring the flow of steam, gases, and liquids.
Exceptional vibration performance with zero drift at zero point, effectively negating the influence of external vibrations.
The ZZYS30 offers integrated temperature and pressure options, significantly reducing installation costs for users.
Outputs available include (0-5) kHz frequency output, (4-20) mA output, along with HART communication and Modbus protocol communication.
Supports parameter settings via Bluetooth communication. With wear-resistant and dirt-resistant features, it requires no mechanical maintenance, boasts a long service life, and is explosion-proof for enhanced safety.
Comprehensive Technical Index
Versatile Measurement Medium: Gas, Liquid, and Steam
Flexible Connection Methods: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications Detailed:
Flange Clamping Type Calibers: 25, 32, 50, 80, 100
Flange Connection Type Caliber Options: 100, 150, 200
Flow Measurement Range: Normal Flow Velocity (Reynolds Number 1.5×104~4×106); Gas: 5~50m/s; Liquid: 0.5~7m/s
Standard Measurement Flow Range for Liquids,
Gas Flow Measurement Range: Refer to Table 2
Steam Flow Range: Refer to Table 3
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature Range:
Room Temperature: -25ºC~100ºC, High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse Voltage Output (High: 8~10V, Low: 0.7~1.3V), Duty Cycle: ~50%, Transmission Distance: 100m
Pulse Current Remote Transmission Signal (4-20 mA), Transmission Distance: 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH50ºC. Material: Stainless Steel, Aluminum Alloy
Power Supply Options: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We will deliver your ordered product at the earliest date as per your requirements.Installation Requirements
Piping Condition
To ensure optimal performance of the Gas Vortex Flowmeter with Low Pressure Loss and High Accuracy, specific installation criteria regarding straight pipe sections must be adhered to. Here are the standard scenarios (D represents the pipe's diameter):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
The sensor should be mounted on horizontal, vertical, or inclined pipes (with fluid flowing bottom to top) that match the sensor's diameter. Ensure there are straight pipe sections both upstream and downstream: 15-20D for the front and 5-10D for the rear.
2.
The pipeline near the liquid sensor must be completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes subject to strong mechanical vibrations.
4.
The inner diameter of straight pipe sections should closely match the sensor diameter. If not, use a slightly larger diameter pipe with a tolerance of ≤3% and no more than 5mm. Avoid installations in areas with strong electromagnetic interference, cramped spaces, or places difficult to maintain..
5.
Horizontal pipeline installation is prevalent for flow sensors. For gas flow measurements with minimal liquid, place the sensor at a higher point. Conversely, for liquid flow with minimal gas, position the sensor at a lower point in the pipeline.
6.
For vertical pipeline installations: When measuring gas, install the sensor vertically with no flow direction constraint. If gas contains some liquid, ensure the flow is from bottom to top. For liquid flow, it should also move from bottom to top to prevent additional load on the probe.
7.
Side mounting of sensors on horizontal pipelines is viable for various fluids, including superheated steam, saturated steam, and low-temperature liquids. Side installation is preferred, if possible, to reduce temperature impacts on the amplifier.
8.
Inverted sensor installation on horizontal pipes is generally discouraged. It's unsuitable for general gases or superheated steam but can measure saturated steam and high-temperature liquids or in situations requiring frequent pipeline cleaning.
9.
For pipelines with insulation layers: When measuring high-temperature steam, ensure the insulation layer does not exceed one-third of the bracket height.
10.
Choosing pressure and temperature measurement points: Based on measurement needs, place the pressure point 3-5D downstream of the sensor and the temperature point 6-8D downstream.