Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
Our unwavering commitment to excellence means that your ordered High Accuracy Electromagnetic Flowmeter with Fast 100ms Response Time will be delivered promptly, exactly when you need it. Experience unparalleled efficiency and timely service with Shandong Zhongziyi Intelligent Technology Co., Ltd.The installation of the High Accuracy Electromagnetic Flowmeter varies according to the specific pipeline conditions at the site. For flowmeters without a ball valve, installation should be performed on a non-pressurized pipeline. This method allows for the selection of flowmeters without the need for a ball valve.
Create a hole with a diameter of 50 mm in the pipeline and prepare to weld a connecting pipe to this opening in the pipeline.
In scenarios requiring continuous flow during loading and unloading, or where media overflow is unacceptable, it is essential to incorporate a ball valve. This necessitates the selection of an insertion-type electromagnetic flowmeter equipped with a ball valve structure.
Create a hole with a diameter of 50 mm in the pipeline and prepare to weld a connecting pipe to this opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The straight pipe sections required are 5D upstream and 3D downstream. This ensures the proper operation of the electromagnetic flowmeter and adherence to accuracy standards.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics.
If turbulence and vortices are generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), they will not affect the measurement.
However, if steady-state vortices are present in the measurement area, both the stability and accuracy of the measurements will be compromised.
In such cases, measures should be adopted to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required. Without them, measurement accuracy will be compromised. Installing a straightener is also advisable, and avoid installation close to control valves and partially open valves.
2.2. Requirements for the Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point to maintain measurement accuracy. a. The inner diameter of the upstream and downstream process pipes must match the sensor's and meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance and optimal performance of the flowmeter, installing a bypass pipe is highly recommended. This is particularly crucial for systems handling heavily contaminated fluids or where cleaning of the flowmeter must occur without halting the flow. a. Facilitates effortless maintenance of the flowmeter. b. Essential for systems with heavily contaminated fluids. c. Allows cleaning of the flowmeter without interrupting the fluid flow.
3. Installation Requirements for Insertion-type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections To achieve accurate measurements, the following inlet and outlet straight pipe sections are necessary: Inlet must be ≥ 10×DN; Outlet must be ≥ 5×DN.
3.2. Requirements for Grounding Points To ensure the reliable operation of the instrument and enhance measurement precision, it is imperative that the sensor is not influenced by external parasitic potentials. The sensor must be well-grounded, with a grounding resistance of less than 10. (If the metal pipeline is already well-grounded, an additional grounding device is not required.)
3.3. Installation Position Requirements The installation position should be in strict accordance with the diagram provided.