Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. At Shandong Zhongziyi Intelligent Technology Co., Ltd., our logistics team prioritizes speed and reliability, guaranteeing your Good Repeatability Flowmeter with High Precision and 4-20mA Output arrives safely and on time. Trust in our dedication to exceptional service and meticulous attention to detail for a seamless delivery experience.The installation of the electromagnetic flowmeter depends on the specific conditions of the site pipeline. For flowmeters without a ball valve, it is crucial to install them on a non-pressurized pipeline, which offers the flexibility to select flowmeters without the need for a ball valve.
Prepare to create a 50mm diameter hole in the pipeline and make arrangements to weld a connecting pipe to the opening.
In scenarios demanding continuous flow during loading and unloading, or where media overflow is unacceptable, utilizing a ball valve is imperative. This necessitates the choice of an insertion-type electromagnetic flowmeter equipped with a ball valve structure.
Similar to previous instructions, create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to the opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The straight pipe sections must adhere to the requirements of 5D upstream and 3D downstream, ensuring optimal performance of the electromagnetic flowmeter while meeting accuracy standards.
The electromagnetic flowmeter's measurement principle is independent of flow characteristics.
If turbulence and vortices are present in the non-measurement areas of the pipeline (like elbows, tangential throttling, or partially open shut-off valves upstream), they will not affect the measurement.
However, steady-state vortices within the measurement area will compromise the stability and accuracy of the readings.
In such cases, take action to stabilize the flow distribution:
1.2. Pipeline-Type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To alleviate the effects of vortices and flow field distortion, the flowmeter requires specific lengths of straight pipe sections upstream and downstream to maintain measurement accuracy. Installing a straightener and avoiding proximity to control valves and partially open valves is advisable.
2.2. Requirements for the Process Pipes The upstream and downstream process pipes at the installation point must meet specific standards to ensure measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter, fulfilling the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the inner diameter of the process pipe). b. The process pipe and the sensor should be concentric, with axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes In order to ensure seamless maintenance and operational efficiency of the flowmeter, the installation of a bypass pipe is highly recommended. This is particularly crucial for scenarios involving heavily contaminated fluids or when the flowmeter needs cleaning without halting the fluid flow. Key stipulations are: a. Ensuring ease of maintenance for the flowmeter. b. Mandatory installation for use with heavily contaminated fluids. c. Enabling cleaning of the flowmeter without interrupting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections For optimal performance, the straight pipe sections at the inlet and outlet must adhere to the following specifications: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN.
3.2. Grounding Requirements To guarantee reliable operation and enhance measurement precision, the sensor must be properly grounded to avoid the influence of external parasitic potentials. The grounding resistance should be less than 10. (If the metal pipeline is effectively grounded, an additional dedicated grounding device is unnecessary.)
3.3. Installation Position Requirements Refer to the provided diagram for precise installation positioning.
COMPANY AND FACTORY PICTURES: