Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The ZZYS30 vortex flowmeter is a versatile and high-performance velocity flow instrument designed for an extensive array of applications.
It is specifically engineered to measure, monitor, and control the flow of liquids, steam, and a broad spectrum of gases with precision and reliability.
Boasting a state-of-the-art structure, it is remarkably resilient to mechanical vibrations, impacts, and contaminants.
With its innovative design featuring no moving parts, this flowmeter ensures no wear and tear, thereby eliminating the need for mechanical maintenance. It offers low pressure loss, stable performance, and unparalleled accuracy.
Effortless to install, the sensor and signal converter can be seamlessly matched to meet specific requirements.
Product features:
Its extensive application range makes it ideal for measuring the flow of steam, gas, and liquid, suitable for various industrial needs.
Outstanding vibration resistance ensures zero drift at zero point, effectively mitigating the impact of external vibrations.
The ZZY30 provides integrated temperature and pressure measurement options, significantly reducing installation costs for users.
Versatile outputs include (0-5) kHz frequency, (4-20) mA, or HART communication/Modbus protocol communication to cater to diverse system requirements.
Supports parameter setting via Bluetooth communication. Robust and durable, it requires no mechanical maintenance, boasts a long service life, and is explosion-proof for enhanced safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Available in 25, 32, 50, 80, 100 mm.
Flange Connection Type Caliber Selection: 100, 150, 200 mm
Flow Measurement Range: Normal measurement flow velocity ranges with Reynolds number 1.5×104~4×106. Gas: 5~50 m/s; Liquid: 0.5~7 m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: Refer to Table 2.
Steam Flow Range: Refer to Table 3.
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle about 50%, Transmission distance up to 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission distance up to 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC24V or lithium battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level IP65.
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We prioritize punctuality and precision in our delivery process, ensuring your order is dispatched at the earliest possible date, precisely as per your requirements.Installation Requirements
Piping condition
The installation of the Easy Install Vortex Flowmeter requires specific straight pipe sections before and after the device, ensuring accurate measurements. The common configurations are listed below (D represents the pipe diameter):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
Install the sensor on a pipe that can be horizontal, vertical, or inclined (with liquid flowing from bottom to top). The pipe must match the sensor diameter and include straight sections of 15-20D upstream and 5-10D downstream to ensure precision.
2.
Ensure the pipe near the liquid sensor is fully filled with the liquid being measured to maintain accuracy.
3.
Avoid installing the sensor on pipes that experience strong mechanical vibrations to prevent measurement errors.
4.
The inner diameter of the straight pipe section should closely match the sensor diameter. If not possible, use a slightly larger diameter with an error margin of ≤3% and not exceeding 5mm. Do not install in areas with strong electromagnetic interference, cramped spaces, or where maintenance is hard..
5.
Horizontal pipeline installation is the most common. For gas flow with minor liquid content, place the sensor at the highest point. For liquid flow with minor gas content, place it at the lowest point to ensure proper measurement.
6.
For vertical pipelines, if measuring gas flow, the sensor can be installed regardless of flow direction. If the gas contains liquid, flow must be from bottom to top. When measuring liquid flow, ensure it flows from bottom to top to avoid extra weight on the probe.
7.
For side installations on horizontal pipelines, sensors should be side-mounted regardless of the fluid type, particularly for superheated steam, saturated steam, and low-temperature liquids. This minimizes temperature effects on the amplifier.
8.
Inverted sensor installations on horizontal pipelines are generally not recommended, except for measuring saturated steam and high-temperature liquids or in cases where pipelines require frequent cleaning.
9.
For pipelines with insulation layers, especially for high-temperature steam, ensure the insulation does not exceed one-third of the bracket height to maintain accuracy.
10.
When pressure and temperature measurements are required near the sensor, position the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream of the sensor.