Product Overview
The ZZYS30 Vortex Flowmeter by Shandong Zhongziyi Intelligent Technology Co., Ltd. is an advanced velocity flow instrument designed for diverse applications.
This state-of-the-art device is perfect for the measurement, monitoring, and control of liquid, steam, and gas flows.
Featuring an innovative structure, it is robust against mechanical vibrations, impacts, and contamination, ensuring reliable performance.
Boasting no moving parts, it offers exceptional durability with no wear and tear, minimal maintenance, low pressure loss, stable operation, and high precision.
Installation is a breeze, with customizable sensor and signal converter pairing to meet specific needs.
Product Features:
Versatile application range, ideal for steam, gas, and liquid flow measurement.
Superior vibration resistance, maintaining zero drift at zero point to neutralize external vibration effects.
The ZZY30 also offers integrated temperature and pressure measurement options, reducing installation costs.
Provides (0-5) kHz frequency output, (4-20) mA output, and supports HART/Modbus communication protocols.
Supports parameter settings via Bluetooth. With wear and dirt resistance, it requires no mechanical maintenance, boasts a long lifespan, and is explosion-proof for added safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: Sizes 25, 32, 50, 80, 100.
Flange Connection Type: Caliber Sizes 100, 150, 200.
Flow Measurement Range: Normal Flow Velocity Reynolds Number 1.5×104~4×106; Gas 5~50m/s; Liquid 0.5~7m/s.
Normal Measurement Flow Range for Liquids,
Gas Flow Measurement Range: Refer to Table 2.
Steam Flow Range: Refer to Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC, High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse Voltage Output Signal, High Level: 8~10V, Low Level: 0.7~1.3V. Pulse Duty Cycle: Approx. 50%, Transmission Distance: 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance: 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH50ºC. Material: Stainless Steel, Aluminum Alloy.
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.
PACKING & SHIPPING
We ensure prompt delivery of your ordered product, aligning with the earliest possible date as per your requirements, guaranteeing efficiency and reliability.Installation Requirements
Piping Condition
The installation of the vortex flowmeter requires a specific straight pipe section both upstream and downstream. The common scenarios are as follows (D represents the diameter of the pipe):
1.
The sensor should be installed on a horizontal, vertical, or inclined pipe (with the liquid flowing from bottom to top) with the same diameter as the sensor. Ensure a specific length of straight pipe both upstream (15-20D) and downstream (5-10D) of the sensor.
2.
The pipe near the liquid sensor must be filled with the liquid being measured.
3.
Avoid installing the sensor on pipes experiencing strong mechanical vibrations.
4.
The inner diameter of the straight pipe should closely match the sensor diameter. If not feasible, a slightly larger diameter pipe with an error ≤3% and not exceeding 5mm should be used. Avoid locations with strong electromagnetic interference, limited space, or areas inconvenient for maintenance..
5.
Horizontal pipeline installation is the most common. For gas flow measurements containing small amounts of liquid, place the sensor at a higher point. For liquid flow measurements containing small amounts of gas, place the sensor at a lower point.
6.
Vertical pipeline sensor installation. For gas flow, the sensor can be installed on a vertical pipeline without flow direction restriction. If the gas contains liquid, ensure the flow is from bottom to top. For liquid flow, ensure the flow is from bottom to top to avoid extra weight on the probe.
7.
Side installation on horizontal pipelines. Suitable for measuring superheated steam, saturated steam, and low-temperature liquids. Side mounting is preferred when possible as it reduces the temperature impact on the amplifier.
8.
Inverted installation on horizontal pipelines is generally not recommended. It is unsuitable for measuring general gases or superheated steam but can be used for saturated steam and high-temperature liquids, or when frequent pipeline cleaning is required.
9.
On pipelines with insulation layers, ensure the insulation layer does not exceed one-third of the bracket height when measuring high-temperature steam.
10.
Selecting pressure and temperature measurement points. Based on measurement needs, place the pressure measurement point 3-5D downstream, and the temperature measurement point 6-8D downstream of the sensor.