Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 268/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
  • Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYZZ
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN200
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection Type
Flange, Thread, Clamping
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67
Range Down
10:1
Electrical Interface
M20×1.5 Special Can Be Customized
Power Supply
3.6V Lithium Battery, 24VDC
Float Material
304 or 316 L, PTFE or P.F.a
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 20.00cm
Package Gross Weight
3.000kg

Product Description

Product Description
 
Production Overview

Introducing the ZYZZ series metal tube float flowmeter, which harnesses the sophisticated variable area measurement principle to offer unparalleled precision.
This powerful tool is perfect for the continuous and accurate measurement of volumetric flow rates, catering to both liquids and gases within sealed pipeline systems.
Renowned for its sturdy and dependable design, the metal tube float flowmeter stands out as a robust and reliable instrument,
featuring an expansive operating temperature range, remarkable accuracy, and exceptional cost-efficiency,
which collectively make it an ideal choice for an array of flow measurement applications.

Features:
Product Features

State-of-the-art enhanced geomagnetic compensation, ensuring precise measurements every time.
An extensive selection of indicator forms to meet diverse needs.
Robust software capabilities, providing a comprehensive and seamless experience.
Innovative dual indication system for enhanced readability and accuracy.
Leading-edge self-damping indicators for stable and reliable performance.
A pioneering measuring tube and magnetic coupling structure for optimal efficiency.
Scientifically engineered lead interface for superior connectivity.
Outstanding anti-interference performance to ensure measurement integrity.
Easily connected opto-isolated output for seamless integration with other systems.
Offers a complete range of installation methods and diverse power supply options for maximum versatility.

The metal rotor flowmeter is a staple in both industrial and laboratory settings, celebrated for its straightforward design, clear operation, minimal pressure drop, and ease of maintenance. Optimized for measuring small flow rates within pipelines of diameter D, it remains an indispensable tool in various applications.< 150 mm, and it can also measure the flow of corrosive media. When in use, the flowmeter must be installed in a vertical section of the pipe, with the fluid medium flowing from the bottom to the top through the rotor flowmeter.
Detailed Photos
 
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Product Parameters
 
Technical Parameters: Explore the cutting-edge specifications of our HART Protocol Flowmeter, featuring a 4-20mA output. This model is engineered with precision to provide accurate flow measurements. Coupled with its robust explosion-proof rating, it guarantees reliability and safety in challenging environments. Delve into its superior performance characteristics for unparalleled operational excellence.
Technical parameters
Measuring range Water: 20~100000L/h Air:0.3~3000Nm /h
Refer to the flow meter
Range down 10:1(DN≤100mm) 5:1 (DN≤100mm)
Accuracy Standard Class 1.5 Special class 1.0
Pressure class (DN15, N25, D40, D50) 0~4.0MPa
(DN80, DN100, DN150)0~1.6MPa
Medium temperature Ordinary: -40ºC~100ºC High temperature:-80ºC~250ºC
Lining PTFE:-40ºC~
Ambient temperature Pointer type: -40ºC~+65ºC
Intelligent type: -25ºC~+65ºC
Connection type Flange, Thread, Clamping
Electrical interface M20×1.5 special can be customized
Protection grade IP67
Ex-proof class Flame proof:ExdIICT6 , EX(ia)IICT6 No:CE18.1473
Medium viscosity DN15≤5Mpa.s (DN25~150)≤5Mpa.s
Power supply 3.6V lithium battery, 24VDC
Measuring pipe material 304, 316L, 304 or 316L, PTFE or F46
Float material 304 or 316L;PTFE or PFA
 
Flow sheet Float material: 1, Cr Ni steel 2, PTFE
Caliber Float No. Flow range H2O Flow range air Press loss Kpa
1 CrNiSteel PTFE 1 CrNiSteel  
DN15 F15.00 F15.01 F15.02 F15.03 F15.04 F15.05 F15.06 F15.07 F15.08 F15.09 F15.10 F15.11 F15.12 F15.13 F15.14 F15.15 F15.16 F15.17 F15.18 F15.19 F15.20 F15.21 F15.22 F15.23 F15.24 F15.25 F15.26 F15.27 F15.28 F15.29 F15.30 10 1/h
15 1/h
20 1/h
25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 I /h
160 1/h
200 I /h
220 I /h
250 I /h
280 I /h
300 I /h
350 I /h
400 1/h
450 1/h
500 1/h
600 1/h
700I/h
800 1/h
9001/h 1000 1/h



25 1/h
30 1/h
35 1/h
40 1/h
45 1/h
50 1/h
55 1/h
60 1/h
70 1/h
80 1/h
90 1/h
100 1/h
120 1/h
160 1/h
200 1/h
220 1/h
250 1/h
280 1/h
300 1/h
350 1/h
400 1/h
0.30 Nm³/h
0.45 Nm³/h
0.60 Nm³/h
0.75 Nm³/h
0.90 Nm³/h
1.05 Nm³/h
1.20 Nm³/h
1.35 Nm³/h
1.50 Nm³/h
1.65 Nm³/h
1.80 Nm³/h
2.10 Nm³/h
2.40 Nm³/h
2.70 Nm³/h
3.00 Nm³/h
3.60 Nm³/h
4.80 Nm³/h
6.00 Nm³/h
6.60 Nm³/h
7.50 Nm³/h
8.40 Nm³/h
9.00 Nm³/h
10.50Nm³/h 12.00Nm³/h 13.50Nm³/h 15.00Nm³/h 18.00Nm³/h 21.00Nm³/h 24.00Nm³/h 27.00Nm³/h 30.00 Nm³
1.5
 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.5
3.5
3.5
3.5
3.5
3.5
3.5






D25
F25.0 F25.1 F25.2 F25.3 F25.4 F25.5 F25.6 F25.7
F25.8 F25.9 F25.10 F25.11
10001/h 12001/h 16001/h 20001/h 25001/h 3000I/h 3500I/h 40001/h 45001/h 5000I/h 55001/h 6000 I /h 10001/h 12001/h 16001/h 2000I/h 2500I/h 3000I/h 3500I/h 4000 I /h 30.0 Nm³/h
36.0 Nm³/h
48.0 Nm³/h
60.0 Nm³/h
75.0 Nm³/h
90.0Nm³/h 105.0 Nm³/h
120.0 Nm³/h
135.0Nm³/h 150.0Nm³/h 165.0Nm³/h 180.0 Nm³
1.5
1.5
3.0
3.0
3.5
3.5
8.0
8.0
8.0
16.0
16.0
16.0




D50
F50.0 F50.1 F50.2 F50.3 F50.4 F50.5 F50.6 F50.7 F50.8 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180001/h 200001/h 25000 I /h 6000I/h 8000I/h 100001/h 120001/h 140001/h 160001/h 180.0Nm³/h 240.0Nm³/h 300.0Nm³/h 360.0Nm³/h 420.0Nm³/h 480.0Nm³/h 540.0Nm³/h 600.0Nm³/h 750.0 Nm³/h 3.0
3.0
4.0
4.0
4.0
8.0
8.0
16.0
16.0


D65
F65.0 F65.1 F65.2 F65.3 F65.4 12000l/h 16000l/h 20000l/h 25000l/h 30000l/h 12000l/h 16000l/h 20000l/h 360.0Nm³/h 480.8Nm³/h 600.0Nm³/h 750.0Nm³/h 900.0Nm³/  



D80
F80.1 F80.2 F80.3 F80.4 F80.5 F80.6 F80.7 5000l/h 30000l/h 35000l/h 40000l/h 50000l/h 60000l/h 65000 l/h 25000 I /h 30000 I /h 35000 I /h 40000 I /h 750.0Nm³/h 900.0Nm³/h 1,050.0Nm³/h 1,200.0Nm³/h 1,500.0Nm³/h 1,800.0Nm³/h 1,950.0 Nm³/h 14.0
14.0
14.0
22.0
22.0
25.0
25.0



D100
F100.0 F100.1 F100.2 F100.3 F100.4 F100.5 50000l/h 60000l/h 70000l/h 80000l/h 90000l/h 100000 l/h 50000l/h 60000 l/h 1,500.0Nm³/h 1,800.0Nm³/h 2,100.0Nm³/h 2,400.0Nm³/h 2,700.0Nm³/h 3,000.0 Nm³/h 30.0
30.0
30.0
30.0
40.0
40.0

D125
F125.0 F125.1 F125.2 100000 l/h 125000 l/h 150000 l/h 100000 l/h 125000 l/h 3000.0Nm³/h 3800.00 Nm³/h 45.0
45.0
48.0
 
Product selection
ZYZZ          A           B          C          D          E          F
Model   structure   wetting material   additional structure     caliber     medium       indicator
ZYZZ Metal pipe floating flowmeter


Standard is
A
Measuring pipe structure, A
A Down in, up out
B Up in, down out
C Side in, side out
D Bottom in, side out
E Right in, left out
F Left in, right out
G Clamp
H Thread connection



Standard is R1
Wetting material B Special consult with factory
R1 1Cr18Ni9Ti,304
RO 0cr18Ni12M02Ti,316
RL 316L
RP PTFE
Ni HC 276
Ti Titanium


Standard is N
Additonal structure C  
N No
Z Damping
J Clamping
G High temperature
L High pressure
Caliber DN DN15 (DN20) DN25 (DN32) (DN40) DN50 (DN65) DN80 DN100 (DN125) DN150 DN200

Medium
Medium type E
L Liquid
G Gas


Standard is 5
M1  
M2  
M3  
M4  
M5  
  Power supply mode
Default A J Local indication no power supply
A 24V DC Two wire power supply 4-20 mA output
B Battery, field LCD display,no signal output
C 100VAC-240VAC 50HZ-60HZ,output 4-20mA

Default L
 Display
L With LCD
  X Without LCD


Defult N
Alarm selection
N No alarm
K1 Upper limit alarm
K2 Lower limit alarm
K3 UP and lower limit alarm


Default D
Ex-proof sign
N No
D Flame-proof ExdIICT6
I Intrinsic safety EX(ia)IICT6


Default N
N No communication protocol
H Hart protocol
M Modbus protocol
P PROfibus-PA field bus
Model selection example:ZYZZ/A/R1/M5/DN25
Intelligent float flowmeter lower in up out 304 material DN25 liquid casting aluminum indicator two wire with LCD no alarm and ex-proof no communication protocol
 

 
Certifications
 
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to ensuring the seamless delivery of your exquisite Good Repeatability Flowmeter. With unmatched precision in customization, we guarantee that your flowmeter, renowned for its high accuracy and versatile threaded mounting options, arrives perfectly tailored to your specifications. Our unwavering commitment to excellence ensures you receive premium service, emphasizing punctual and efficient delivery to cater to your distinct needs.
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Installation Instructions
 
Installation:

The metal rotor flowmeter stands as a pinnacle of precision in variable area flow measurement, expertly gauging the position of the float to deliver accurate readings.

With its robust all-metal construction and innovative modular design, this flowmeter is truly remarkable. Its compact design ensures minimal pressure loss and boasts an impressive range ratio of 10:1,
making it exceptionally versatile across a multitude of industries. This device thrives even in the most challenging and severe environments,
performing admirably for flow and process control demands, especially where low velocities, minimal flow rates, and rigorous medium conditions prevail.

Ensuring the flawless function of the metal rotor flowmeter rests heavily on its proper installation. Key installation considerations include:

(1) The flowmeter must be installed in a vertical position, allowing the fluid to flow seamlessly from bottom to top. It is crucial to maintain a straight pipe section, at least five times the diameter of the instrument, at both inlet and outlet. For new installations, make sure to thoroughly flush the pipeline before attaching the flowmeter.

(2) Strategically place a valve upstream and a flow control valve 5 to 10 times the instrument diameter downstream. For smaller instruments, an upstream filter is essential. If the medium has magnetic materials, ensure a magnetic filter is positioned ahead of the flowmeter.

(3) Simplify maintenance and replacement by integrating a bypass pipeline during the flowmeter's installation.

(4) Should the medium be particularly dirty, it is vital to clean the pipes and float regularly to ensure optimal performance.

(5) The metal rotor flowmeter typically offers a measurement accuracy level of 1.5. For applications requiring superior precision, alternative instruments are recommended over the metal tube rotor flowmeter.

Company and factory photos
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Our Advantages
 
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating


Revolutionary Team Building Initiatives

We are steadfast in our belief that crafting a victorious team stems from a foundation of unparalleled excellence, seamless collaboration, and unwavering dedication!
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
Exhibition Highlights

In a bold stride towards global recognition, we are actively seeking out international collaborations by presenting our cutting-edge innovations at prestigious global exhibitions.
Hart Protocol Flowmeter with 4-20mA Output and Explosion Proof Rating
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now