IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities

Product Details
Customization: Available
After-sales Service: 24/7 Online After Sales Services
Warranty: 12 Months After Delivery Date
Still deciding? Get samples of US$ 450/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
  • IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZYDC
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Size
DN15-DN500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Conductivity Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Response Time
100ms
Output
4-20mA
Explosion Proof
Exd II CT6
IP
67,68
Velocity Range
0.1-15m/ S
Range Down
150:1
Repeatability
+-0.1%
Conductivity Range
≥5μ S / Cm
Ambient Temperature
-25°ºC~+60°ºC
Relative Humidity
-25°ºC~+60°ºC
Transport Package
Carton
Specification
30CM*20CM*50CM
Trademark
CAMCT
Origin
China
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 40.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 
Production Overview

Electromagnetic Flow Meter Product Overview.
The ZYDC electromagnetic flow meter is an advanced instrument consisting of two key components: a high-precision sensor and a state-of-the-art converter, designed on the principles of Faraday's electromagnetic induction law. It is tailored for measuring conductive fluids with unmatched accuracy and reliability. After continuous enhancements, this product now excels in excitation technology, lining technology, and intelligent systems, positioning it as a national leader. It adheres rigorously to standards such as JB/T9248-2015 and JJG 1033-2007, ensuring top-tier performance.

Features:

- Exhibits stable performance with exceptional repeatability, achieving high accuracy up to 0.2%.
- Non-intrusive flow measurement ensures no pressure loss and minimizes clogging risks.
- Exceptionally adaptable to highly corrosive and abrasive fluids, ensuring longevity.
- Facilitates operation without cover removal, thanks to mobile Bluetooth and infrared remote control.
- Incorporates stainless steel mesh technology, optimally designed for negative pressure conditions.
- Supports GPRS and Bluetooth for wireless transmission; fully compatible with MODBUS and HART communication protocols.
- Powered by a 16-bit embedded microprocessor, offering rapid computation, precision, and low-frequency square wave excitation for stable and low-energy flow measurement.
- Utilizes SMD components and SMT, ensuring high circuit reliability. Allows on-site measurement range modifications for optimal data acquisition terminal compatibility.
- Measurement results remain unaffected by fluid pressure, temperature, density, and viscosity, guaranteeing consistent accuracy.
- Features diverse digital communication outputs including RS485, RS232, HART, Modbus, and optional Profibus-DP.
- Equipped with self-check, self-diagnosis, and alarm functionalities for enhanced operational reliability.
- Boasts three internal accumulators for displaying forward, reverse, and differential cumulative amounts separately, with an internal clock recording up to 16 power outage instances (optional).
- The ultra-low EMI switch power supply is engineered for broad power voltage ranges, providing superior EMI resistance.
Detailed Photos
 
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
Product Parameters
 
Cutting-edge Technical Parameters:
Product advantages
Project CAMCT Others
Lower flow limit 0.1m/ s (linear accuracy guaranteed)
 
0.3m/ s (linear accuracy guaranteed)
 
Response time 100ms ≥3S
Strong steady flow function have Don't have
 
Product category
Medium Conductive liquid such as sewage, chemical liquid and tap water
Output 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol
Accuracy class Class 0.3, 0.5 Velocity range 0.1-15m/ s
Medium temperature -20~+160ºC Ex-proof grade Exd lI CT6 G
Protection grade IP67, Special requirements could up to IP68
 
Technical parameters
Executive standards Electromagnetic flowmeter(JJG 1033-2)
Nominal caliber (can be customized) Pipe type PTFE lining: DN15-DN2000
Pipe type rubber lining: DN65-DN2000
Pipe type PFA lining: DN40-DN600
Flow direction Positive, negative, net flow
Range down 150:1
Repeatability ±0.1%
Medium temperature Regular rubber lining: -20ºC~+60ºC
Normal temperature rubber lining: -20ºC~+90ºC
PTFE lining: -30ºC~+120ºC
High temperature PFA lining: -20ºC~+160ºC
Rated working pressure (DN15~DN25) ≤4.0MPa
(DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa
Velocity range 0.1-15m/ s
Conductivity range ≥5μ s / cm
Communication output RS485, HART protocol, GPRS output
Power supply 220VAC,Tolerance 15%or 24VDC,ripple wave≤5%
Required straight pipe segment length Upstream≥5DN, Downstream≥2DN
Connection type Flange connection: HG20592-2015
Protection grade IP67
Ex-proof Class ExdIIct6  Certificate No.:CE19.14
Ambient temperature -25°ºC~+60°ºC
Relative humidity 5%~95%
Total power consumed <7.5W
 
Measurable range
Caliber Min adjustable range(0.3m/s, per hour) Max adjustable range
(10m/s, per hour)
mm inch m³/h GPM m³/h G
15 0.5 0.19 0.84 6.36 28.0
25 1 0.53 2.35 17.7 78.0
32 1.25 0.87 3 29.0 100
40 2 1.36 600 45.2 200
50 2 2.12 9.35 70.7 310
65 2.5 3.58 15.0 119.5 502
80 3 5.43 24.0 181.0 800
100 4 8.48 37.5 282.7 1250
125 5 13.25 60.2 441.8 2008
150 6 19.1 84.0 636.1 2800
200 8 34.0 150.0 11313 5000
250 10 53.0 41.0 1767 8031
300 12 76.3 347 2544 11565
350 14 103.9 472.3 3463 15741
400 16 135.7 616.9 4523 20560
 
Selection list  
ZYDC Intelligent electromagnetic flowmeter  
M Integral  
F Split  
Lining material F PTFE  
Z Rubber lining  
A PFA  
Pipe connection C1 HG 1.0Mpa flange type  
C2 HG 1.6Mpa flange type  
C3 HG 2.5Mpa flange type  
E1S DIN PN10 clamping type  
E2S DIN PN16 clamping type  
Instrument caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200  
Nominal caliber  
Electrode material L 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
N No  
Electrode ring S 316L  
H HC 276  
Ti Titanium  
Ta Tantalum  
P Platinum-iridium alloy  
Connection      
2 1/2" NPT Internal thread  
4 M20*1.5 Internal thread  
Power supply A2 220V AC  
D1 24V DC  
Ex-proof Explosion-proof sign  
N No ex-proof  
D Flame-proof EXD II CT6  
Communication protocol Communication protocol  
N No  
H Hart protocol  
M Modbus protocol  
P Profibus-PA  
   
Selection example: ZYDC/M/F/C2/L/DN25  
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol  
 
Certifications
 
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities

PACKING & SHIPPING

At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to ensuring that your IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities is delivered promptly and meets all your specifications. Our commitment to timely and efficient service guarantees that your product arrives when you need it most, with all the necessary care and precision.
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
Installation Instructions
 

The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline, which allows for the selection of flowmeters without a ball valve for simplified integration.
A hole with a diameter of 50 mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline for secure and efficient installation.
For situations requiring continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a diameter of 50 mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline for secure and efficient installation.

Measuring range Recommend using range 0.5m/s to 10m/s continuously adjustable
 
Max using range 0.2m/s ~ 15m/s continuously adjustable
 
Output The switching quantity can be set to Pulse output (up to 1000HZ)
High/low flow alarm
Empty pipe alarm
Flow direction indication
Fault alarm
Current output Output 4-20mA
Configuration mode Field configuration with three manual keys
Field configuration through remote controller
Field configuration by hand operator
Memory EEPROM memory that does not disappear and does not require battery storage
 
 

The requirements for the straight pipe sections are 5D upstream and 3D downstream. This configuration ensures the proper operation of the electromagnetic flowmeter and meets the highest accuracy standards.

The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics, ensuring reliable performance under varied conditions.
If certain amounts of turbulence and vortices are generated in the non-measurement area of the pipeline, such as at elbows, tangential throttling, or upstream partially open shut-off valves, it will not affect the measurement.

However, if steady-state vortices exist in the measurement area, it will impact the stability and accuracy of the readings.
In such cases, various measures should be taken to stabilize the flow distribution, ensuring optimal measurement performance:

  1. Increase the length of the straight pipe sections both upstream and downstream.
  2. Utilize a flow stabilizer to maintain uniform flow distribution.
  3. Reduce the cross-section of the measurement point to minimize flow disturbances.
  1. Requirements for the External Environment
    1. The flowmeter should be installed away from areas with significant temperature fluctuations or high-temperature radiation from surrounding equipment. If installation in such environments is unavoidable, proper insulation and ventilation measures must be taken.
    2. For optimal performance, the flowmeter is best installed indoors. If outdoor installation is necessary, it should be protected from rain, flooding, and direct sunlight, with appropriate moisture-proof and sun-proof measures in place.
    3. Avoid installing the flowmeter in environments containing corrosive gases. If installation is necessary, effective ventilation measures should be implemented.
    4. To facilitate easy installation, maintenance, and upkeep, ensure there is ample space around the flowmeter.
    5. The installation site should avoid areas with magnetic fields and strong vibration sources. If significant vibration in the pipeline exists, supports should be provided on both sides of the flowmeter to stabilize the pipeline.

1.2. Pipeline-type Electromagnetic Flowmeter

2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths of straight pipe sections upstream and downstream of the flowmeter are required, otherwise, measurement accuracy will be compromised. Installing a straightener and avoiding placement close to control valves and partially open valves is advisable.

2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point to maintain measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and sensor must be concentric with an axial deviation not exceeding 0.05DN.

2.3. Requirements for Bypass Pipes: To ensure seamless maintenance and optimal performance of your flowmeter, it is recommended to install a bypass pipe. This becomes essential in instances involving heavily contaminated fluids or when there is a need to clean the flowmeter without halting the fluid flow. a. Facilitates the maintenance of the flowmeter. b. Mandatory for handling heavily contaminated fluids. c. Ensures continuous fluid flow during flowmeter cleaning operations.

3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters: Detailed guidance for the proper installation of insertion-type electromagnetic flowmeters.

3.1. Requirements for Straight Pipe Sections: Ensure precise measurement and smooth operation by adhering to the following guidelines for straight pipe sections. Inlet: Must be ≥ 10×DN; Outlet: Must be ≥ 5×DN.

3.2. Requirements for Grounding Points: To guarantee reliable performance and enhanced measurement accuracy, the grounding of the sensor is crucial. The grounding resistance should be less than 10. If the metal pipeline is well-grounded, a dedicated grounding device is unnecessary. Proper grounding mitigates the influence of external parasitic potentials, ensuring consistent and accurate readings.

3.3. Requirements for Installation Position: Detailed positioning requirements for optimal installation are illustrated in the accompanying diagram.


COMPANY AND FACTORY PICTURE: Visual representations of Shandong Zhongziyi Intelligent Technology Co., Ltd.'s facilities.

IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
Our Advantages
 
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities


Team Building: At Shandong Zhongziyi Intelligent Technology Co., Ltd., we prioritize forging a cohesive and high-performing team. Our belief is that teamwork leads to extraordinary achievements.

We believe that the best team always wins! Our commitment to fostering a supportive and collaborative environment ensures that our team is equipped to deliver exceptional results consistently.
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
Exhibition Pictures: Visualize our journey and achievements through a collection of vivid exhibition pictures, showcasing our global presence and the strides we've taken in the industry.

We are actively seeking international cooperation through global exhibitions. Our participation in these events underscores our commitment to expanding our reach and forging meaningful partnerships around the world.
IP67 Rated Flowmeter with Anti-Vibration and 4-20mA Output Capabilities
FAQ
1, What kind of product do you supply?

Our product includes pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow meter.

2,What is your product and technology advantages?

 Our factory was built on 1966 with almost 60 years manufacturing and R&D experience. We are also the supper close partner of Rosemount in China.  our technology closely keeps following Rosemount. Especially, our remote pressure transmitter technology and stability could be No. one in China.

3, Where is your factory location?

Our factory located in Zibo, Shandong province, China, which is top three instrument production area. And take an area of more than 18000 square meters.

4, Can we visit your factory?

You are always welcome to our factory at any time at your convenience.

5, What is the warranty of your product?

Our product warranty is 12 months from the shipping date, but we provide lifetime maintenance.

6, What are your payment terms?

Now, we can accept 50% down payment and 50% balance payable 5 days before delivery by T/T, west union, PayPal and trade assurance online payment.

7, What kind of certification do you have?

We have ISO9001, CCC, CNAS laboratory accreditation certification, Flame-proof certification and intrinsic safety certification, SIL certificate. ECM certificate, Russia EAC and PAC certificate and several invention patents.

8, How long is your delivery date?

For peak season is 4 weeks and 2 weeks for offseason, but no matter peak or off season we will try our best to meet your requirements.

9, How is your after sales services?

 Our products quality  enjoy very good quality reputation and has almost no warranty caused by product itself, but we still provide 24/7 online
services for our customer for any installation, commision, running or other problems.

10, How can I send inquiry?

 You can send inquiry through our email or cellphone as below:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now