Easy Install High Accuracy Flowmeter for Gas and Liquid Applications

Product Details
Customization: Available
After-sales Service: 24/7 After Sales Services
Warranty: 12 Months From Delivery
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
  • Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
ZZYS30
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Steam, Liquid
Size
DN15-DN300
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Repeatability
0.3%
Medium Temperature
-40-240
Ambient Temperature
-40-85
Medium Pressure
≤100 Bar, More Pressure Need Be Customized
Material
Sensor: 316L, Hc276
Output
Two Wire 4~20mA
Ex-Proof Class
Exd II CT6 CE19.1438 Ex ( Ia ) II CT6
Housing Protection Class
IP67
Mounting Type
Integral Mounting, Split Mounting
Transport Package
Carton
Specification
20CM*10CM*30CM
Trademark
CAMCT
Origin
China
Production Capacity
50, 000.00 Sets/Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 50.00cm
Package Gross Weight
5.000kg

Product Description

Product Description
 

Product Overview

The ZZYS30 Vortex Flowmeter is an advanced velocity flow instrument designed for a multitude of applications.
Ideal for measuring, monitoring, and controlling the flow of liquids, steam, and a broad spectrum of gases.
Boasting a cutting-edge structure, it is highly resistant to mechanical vibrations, impacts, and contamination.
Featuring no moving parts, it ensures zero wear and tear, requires no mechanical maintenance, has low pressure loss, and delivers stable performance with exceptional accuracy.
Its installation is effortless, with flexible pairing of the sensor and signal converter tailored to your needs.


Product Features:

Extensive application versatility, perfect for measuring the flow of steam, gas, and liquid.
Outstanding vibration resistance, zero drift at the zero point, effectively minimizing the impact of external vibrations.
The ZZY30 offers integrated temperature and pressure options, reducing installation costs for users.
Provides (0-5) kHz frequency output, (4-20) mA output, and supports HART communication/Modbus protocol communication.
Enables parameter setting via Bluetooth communication. Durable, dirt-resistant, no mechanical maintenance needed, long-lasting, and explosion-proof for enhanced safety.

Detailed Photos
 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Product Parameters
 

Technical Index

Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100 mm
Flange Connection Type Caliber Selection: 100, 150, 200 mm
Flow Measurement Range: Normal Measurement Flow Velocity Range Reynolds Number: 1.5×104~4×106; Gas: 5~50 m/s; Liquid: 0.5~7 m/s
Normal Measurement Flow Range: Liquid
Gas Flow Measurement Range: See Table 2
Steam Flow Range: See Table 3
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse Voltage Output Signal, High Level: 8~10V, Low Level: 0.7~1.3V. Pulse Duty Cycle: ~50%, Transmission Distance: 100m
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance: 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC; Humidity: 5~90% RH50ºC. Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65

Technical parameters
Medium Steam, Gas, Liquid
Measuring range See flow1-3
Caliber DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300
Medium pressure 100 bar, more pressure need be customized
Medium temperature -40°C~+240°C
Ambient temperature Ordinary type: -40°C~+85°C
Ex-proof type: -40°C~+60°C
Accuracy Liquid, Re20000 is ±1.0%, gas and steam, ±1.5%
Repeatability ±0.3%
Material Measuring pipe:304,316L, HC276
Sensor: 316L, HC276
Converter shell: casting aluminum
Instrument caliber Flange connection: DN15-DN300
Clamping connection: DN15-DN100
Flange standard DIN, ANSI, HG20592 (Can be customized)
Pressure loss
Gasandliquid

saturated steam
ΔP=Cqv²Px          ΔP: pressure loss(pa)
                        qv: volume flow
                        qm: mass flow
ΔP=Cqm²Px                    PX: density
                        C: constent
Display Two-line LCD display, four button operation
Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display
Power supply Ordinary type: (14~36) VDC
Ex-proof type: (14~30) VDC
Battery power supply
Loading No-ex-proof: RB=(UB-14DVC)/22MA1200Ω
Ex-proof: RB=(UB-14DVC)/22MA≤600Ω
Output Two wire 4~20mA
Ex-proof class Exd II CT6 CE19.1438 Ex ( ia ) II CT6
Cable interface 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread)
Housing protection class IP67
Connection type Flange (DN15-DN300), Clamping (DN15-DN100)
Mounting type Integral mounting, split mounting (special shielded cable connect the pipe and indicator)
 
Measuring Range:
Gas
Air: t=20°C    p=1.013bar abs =1.7210-4 mpa.s  Q: flow (sheet 1)
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 6.79 32.56
DN25 24 10.20 113.94
DN40 38 25.3 326.63
DN50 50 43.89 565.49
DN80 74 96.14 1238.64
DN100 97 165.14 2128.27
DN150 146 374.23 4821.57
DN200 193 702.95 9056.8
DN250 253 1123.7 14478
DN300 305 1632.1 21028
 
Liquid
Water: t=20°C        p=1.013bar abs       10cp                 Q: flow
Nominal diameter Internal diameter Qmin(m3/h) Qmax(m3/h)
DN15 16 0.45 5
DN25 24 0.81 11.40
DN40 38 2.04 28.57
DN50 50 3.53 49.47
DN80 74 7.74 108.37
DN100 97 13.30 186.21
DN150 146 30.13 421.86
DN200 193 52.66 792.42
DN250 253 90.5 1266.8
DN300 305 113.41 1839.8
 
Saturated steam

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=1bar G P=3.5bar G P=5.2bar G P=7 bar G
ρ=1.13kg/m3 ρ=2.43kg/m3 ρ=3.28kg/m3 ρ=4.17kg/m3
t=120.6°C t=148.2°C t=160.4°C t=170.6°C
min max min max min max min max
DN15 16 5.87 36.97 7.68 79 8.93 106.68 10.06 135.69
DN25 24 11.82 129.39 17.26 276.4 20.09 373.53 22.66 474.82
DN40 38 29.64 370.71 43.33 792.33 50.63 1070.2 56.8 1361.2
DN50 50 51.31 641.82 75.02 1371.8 87.19 1852.8 98.33 2356.6
DN80 74 112.41 1405.8 164.33 3004.7 191 4058.4 215.39 5161.8
DN100 97 193.14 2415.5 282.36 5162.7 328.16 6973.3 370.09 8869.2
DN150 146 437.56 5472.4 639.69 11696 743.45 15798 838.44 20093
DN200 193 821.91 10279 1201.6 21970 1396.5 29675 1574.9 37743
DN250 253 1313.9 16433 1920.9 35122 2232.5 47439 2517.7 60337
DN300 305 1908.3 23866 2789.8 51010 3242.4 68899 3656.6 87630
 

Nominal
Diameter

Inner
Diameter
Mass flow Qm (kg/h) under different pressure and density
P=10.5 bar G P=14 bar G P=17.5 bar G P=20 bar G
ρ=5.89kg/m3 ρ=7.6kg/m3 ρ=9.32kg/m3 ρ=10.54kg/m3
t=186.2°C t=198.5°C t=208.5°C t=215.6°C
min max min max min max min max
DN15 16 12.78 191.71 16.51 247.55 20.23 303.36 22.89 343.32
DN25 24 26.93 670.88 30.6 857.88 33.87 955.48 36.04 1201.41
DN40 38 67.51 1878.2 76.72 2150.7 84.93 2395.3 90.35 2557.7
DN50 50 116.89 3251.7 132.82 3723.4 147.03 4147 156.42 4428.1
DN80 74 256.03 7122.4 290.93 8155.8 322.06 9083.7 342.62 9699.3
DN100 97 439.91 12238 499.9 14013 553.38 15608 588.69 16666
DN150 146 996.62 27725 1132.5 31747 1253.7 35359 1333.7 37756
DN200 193 1872.1 52079 2127.3 59634 2354.9 66419 2505.2 70921
DN250 253 2992.7 83254 3400.71 95333 3764.6 106180 4004.9 113380
DN300 305 4346.5 120920 4939.1 138460 5467.5 154210 5816.5 164660
 
Selection list
model Explanation
ZZY30              
Connection F             Flange connection
W Flange clamping
Temperature
Resistance Class
T1 Match with 250°c probe
T2 Match with 350°c probe







Nominal diameter
015 DN15
020 DN20
025 DN25
032 DN32
040 DN40
050 DN50
065 DN65
080 DN80
100 DN100
125 DN125
150 DN150
200 DN200
250 DN250
300 DN300

Structure
Z Integrated T and P compensation
F Regular model
S Split
Material R1 304
RL 316L



Instrument model
N 24V power supply Output 3 wire pulse
V1 24V power, on-site display, 4-20mA, RS485, Impulse output
V1

B
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output
Pressure Class N Normal
H High pressure
 
Certifications
 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications

PACKING & SHIPPING

We will deliver your order product at the earliest date as required by you, ensuring a swift and efficient shipping process tailored to meet your deadlines and expectations.
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Installation Instructions
 

Installation Requirements

Piping condition
The installation of vortex flowmeter requires a certain straight pipe section before and after, and the common situations are as follows (D is the diameter of the pipe) :

Piping condition upstream Downstream
Concentric shrinkage
pipe full open gate valve
15D 5D
∠90° square elbow 20D 5D
Same plane 2∠90°elbow 25D 5D
Semi-open gate valve regulating valve 50D 5D
Different plane 2∠90°elbow 40D 5D
With rectifier tube bundle 12D 5D
 

1.
The sensor should be installed on a pipe that is horizontal, vertical, or inclined (with the liquid flowing from bottom to top) and has the same diameter as the sensor. There should be a certain length of straight pipe upstream and downstream of the sensor, with the length meeting the requirements of 15-20D for the front straight pipe section and 5-10D for the rear straight pipe section.
2.
The pipe near the liquid sensor should be filled with the liquid being measured.
3.
The sensor should not be installed on a pipe with strong mechanical vibrations.
4.
The inner diameter of the straight pipe section should be as consistent as possible with the sensor diameter. If they cannot be the same, a slightly larger diameter pipe should be used, with an error of ≤3% and not exceeding 5mm. The sensor should not be installed in locations with strong electromagnetic interference, limited space, or inconvenient maintenance..
5.
Horizontal pipeline installation is the most common method for flow sensors. When measuring gas flow, if the gas being measured contains a small amount of liquid, the sensor should be installed at a higher point in the pipeline. When measuring liquid flow, if the liquid being measured contains a small amount of gas, the sensor should be installed at a lower point in the pipeline.
6.
Sensor installation in vertical pipelines. When measuring gas flow, the sensor can be installed on a vertical pipeline with no restriction on flow direction. If the gas being measured contains a small amount of liquid, the gas flow should be from bottom to top. When measuring liquid flow, the liquid flow should be from bottom to top to avoid additional weight on the probe.
7.
Side installation of sensors on horizontal pipelines. Regardless of the fluid being measured, sensors can be side-mounted on horizontal pipelines, especially when measuring superheated steam, saturated steam, and low-temperature liquids. If conditions allow, side mounting is preferred as it minimizes the temperature impact on the amplifier.
8.
Inverted installation of sensors on horizontal pipelines. This installation method is generally not recommended. It is not suitable for measuring general gases or superheated steam. It can be used for measuring saturated steam and is suitable for measuring high-temperature liquids or situations where pipelines need frequent cleaning.
9.
Installation of sensors on pipelines with insulation layers. When measuring high-temperature steam, the insulation layer should not exceed one-third of the bracket height.
10.
Selection of pressure and temperature measurement points. Depending on the measurement requirements, when pressure and temperature need to be measured near the sensor, the pressure measurement point should be 3-5D downstream of the sensor, and the temperature measurement point should be 6-8D downstream of the sensor.

Company Profile
 
Shandong Zhongziyi Intelligent Technology Co., Ltd., a beacon of innovation and quality,
is strategically located in the prestigious Zibo Science and Technology Industrial Park.
Our expansive facility spans over 18,000 square meters, providing ample space for cutting-edge operations.
Equipped with state-of-the-art manufacturing capabilities, we are steadfastly
committed to
the research and development,
manufacturing,
sales, and service of premium pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we proudly hold the ISO9001 quality management system certification and are recognized as a high-tech enterprise in Shandong Province.
A close and trusted partner of Rosemount in China, our technology advances in lockstep with industry leaders.
With nearly 60 years of dedicated expertise in instrument R&D and production,
we boast a wealth of technological innovation and exceptional customer service experience.
Our products are extensively utilized across industries such as Petroleum, Chemicals, Papermaking,
Metallurgy,
Medicine,
Food,
Power, and Machinery. Our expansive sales network covers the entire nation and extends internationally, earning profound trust and commendations from our esteemed users.
At the heart of our company lies our core philosophy: 'Quality First, Customer First.'
We warmly invite customers to visit our factory and explore opportunities for mutually beneficial collaboration.

COMPANY AND FACTORY PICTURE:
 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Our Advantages
 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Features:
  1. The structure is simple yet robust, with no moving parts, offering exceptional reliability and durability for extensive use.Operation is highly dependable, ensuring consistent performance over time.
  1. Installation is straightforward, and maintenance is remarkably convenient, reducing downtime and operational costs.
  1. The detection sensor remains isolated from the measured medium, guaranteeing stable performance and an extended lifespan.
  1. The output is a pulse signal directly proportional to the flow rate, ensuring no zero drift and maintaining high accuracy.
  1. Wide measurement range, accommodating diverse applications with ease.Range down up to an impressive 1:50.
  1. Low pressure loss, resulting in low operating costs and substantial energy-saving benefits. Within a certain range of Reynolds numbers, the output signal frequency remains unaffected by changes in the fluid's physical properties or composition. The meter coefficient depends solely on the vortex shedding body's shape and size, eliminating the need for volume flow compensation. Typically,recalibration of the meter coefficient is unnecessary after component changes.


Team Building: We believe that the best team always triumphs!


 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
Exhibition Pictures: Actively seeking global cooperation through international exhibitions to expand our reach.


 
Easy Install High Accuracy Flowmeter for Gas and Liquid Applications
FAQ
 
1, What kind of product do you supply?

O
ur product
includes
pressure transmitter, temperature transmitter, level transmitter, pressure gauge, temperature gauge and flow
meter.

2,What is your product and technology advantages?

Our factory was established in 1966, boasting nearly 60 years of unparalleled expertise in manufacturing and R&D. We are also the premier partner of Rosemount in
China.
Our technology consistently
mirrors Rosemount's innovations. Particularly, our remote pressure transmitter technology and stability are renowned as the best in China.

3, Where is your factory location?

O
ur factory is located in Zibo, Shandong province, China, a leading hub for
instrument production.

A
nd it spans over 18,000 square meters.

4, Can we visit your factory?

Y
ou are always welcome to visit our factory at any time that suits your schedule.

5, What is the warranty of your product?

O
ur product warranty extends for 12 months from the shipping date. Additionally, we offer
lifetime
maintenance services.

6, What are your payment terms?

Currently
, we accept a 50% down payment, with the remaining 50% due 5 days before delivery. Payments can be made via T/T, Western Union,
PayPal
, and Trade Assurance online payment.

7, What kind of certification do you have?

W
e hold ISO9001, CCC, CNAS laboratory accreditation, Flame-proof certification, intrinsic safety certification, SIL certificate, ECM certificate, and Russia EAC and PAC certificates,
a
s well as
multiple
invention patents.

8, How long is your delivery date?

D
uring peak season, delivery takes 4 weeks, while in the off-season it is 2 weeks. Regardless of the season, we strive to meet your requirements efficiently.

9, How is your after-sales service?

Our products are highly regarded for their quality, with minimal warranty claims. Nevertheless, we provide 24/7 online
support for any installation, commissioning, operational issues, or other concerns.

10, How can I send an inquiry?

Y
ou can send your inquiries through our email or cellphone as listed below:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now