Basic Info.
Type
Remote Pressure Transmitter
Structure Type
Diffused Silicon Pressure Transmitter
Measuring Medium
Gas, Steam, Liquid
Accuracy Grade
0.1%F.S, 0.25%F.S, 0.5%F.S
Certification
C.C.C, I.S.O 9001, E.C.M, E.a.C, P.a.C,S.I.L,
Capacity
>50, 000.00 Sets
Output
4-20 Ma, Mod Bus, PA
Ambient Temperature
-30~70 Celsius Degree
Long Term Stability
<=0.03%F.S/Year
Electrical Interface
2-M 20*1.5, 2-1/2 N.P.T
Process Interface
1/4 N.P.T
Diaphragm Material
316 L, H C, Tantalum, 316 L Gold Plating
Mounting
Direct Mounting, Flange or Rack
Medium Temperature
-40~200 Celsius Degree
Explosion Proof
Exd II CT6 GB, Exia II CT6 Ga
Transport Package
Carton, Plywood Case
Specification
20CM*10CM*30CM
Product Description
ZY8000Y Intelligent Remote Transmitter
Advanced Intelligent Flange Remote Transmitter Sensing
Efficiently measures
pressure via remote
transmission
devices, then seamlessly transmits to the transmitter
through a sophisticated oil-filled capillary system.
Capable of measuring liquid levels and differential pressure (D/P), it's ideal for high-temperature applications where the transmitter needs to be positioned remotely.
Perfect for handling high viscosity, easily precipitable, crystalline, or corrosive media. Extensively utilized across industries such as petroleum, chemical, metallurgy, power generation, environmental protection, new energy sectors, and machinery equipment.
The ZY8000 Intelligent Transmitter offers unparalleled precision with a basic accuracy of 0.1% FS, reaching up to an impressive 0.075% FS at its peak. Even after a decade of continuous operation, it retains an astonishing 99.9% accuracy, significantly reducing maintenance costs. Enclosed in a robust metal housing with fully sealed measuring elements, it deftly withstands extreme chemical and mechanical stresses. Additionally, its exceptional anti-electromagnetic interference capabilities ensure the ZY8000 remains highly stable and reliable.
The ZY8000 is equipped with an advanced integrated diagnostic function that monitors its status in real-time. Upon detecting predefined anomalies, it enters a fault alert mode, emitting alert currents (3.6mA or 22.8mA) and providing control signals for system interlock and SIS safety systems. In the event of a fault, the LCD screen displays an 'Err' message, automatically identifying and showing the problematic unit. This feature streamlines the processes of maintenance, repair, and replacement, making them more straightforward and efficient.
Product Detail Picture
Every detail of the product has been meticulously crafted to ensure superior performance and durability.
Intelligent flange remote transmitter sensing
The measured pressure is transmitted remotely
using advanced transmission devices, then sent to the transmitter
through an oil-filled capillary. It can measure liquid levels and differential pressures (D/P), making it perfect for high-temperature environments (where the transmitter must be placed remotely).
Ideal for applications involving high viscosity, crystallization, or corrosive mediums, this transmitter is widely used across petroleum, chemical, metallurgy, power generation, environmental protection, new energy, and machinery equipment industries.
Product Features
Adhering to the superior performance and stability of the ZY8000 intelligent high-precision pressure/differential pressure transmitter,
it features an imported mono-crystalline silicon chip and a lightning protection circuit design. The isolated power supply and sensor signal significantly improve stability and anti-interference capabilities.
With various materials and types of remote devices combined with a specialized oil-filling device, this transmitter maximizes accuracy and meets comprehensive cleanliness requirements. It boasts excellent product stability, achieving the highest accuracy of up to 0.075% under normal temperatures. The explosion-proof shell structure is suitable for all weather conditions and is compatible with the HART protocol.
Measuring Range
Range code | GP Gauge pressure (Kpa ) |
Measuring range | Overload limit | Rated pressure(Max) |
03 | -6~6 | 2000 | Flange rated pressure and the minimum value of the upper limit of the measuring range |
04 | -40~40 | 5000 |
05 | -100~100 | 7000 |
06 | -100~400 | 10000 |
07 | -100~4000 | 10000 |
08 | -100~10000 | 10000 |
Range code | DP Differential pressure (Kpa) |
Range | Measuring range | Unilateral overpressure | Bilateral static pressure | Rated pressure (Max) |
03 | 6 | -6~6 | 2000 | 16000 | The lower value of remote flange rated pressure and bilateral static |
04 | 40 | -40~40 | 5000 | 25000 |
05 | 100 | -100~100 | 7000 | 25000 |
06 | 400 | -400~400 | 10000 | 25000 |
07 | 4000 | -500~4000 | 10000 | 25000 |
08 | 10000 | -500~10000 | 10000 | 25000 |
Technical Parameters
Accuracy: Choose from 0.1%FS, 0.25%FS, or 0.5%FS for unparalleled precision.
Measured Parameters: Pressure and Differential Pressure for versatile applications.
Output: Reliable 2-wire 4~20mA+HART for seamless integration.
4-wire RS485 Output: MODBUS protocol and PA protocol for advanced connectivity.
Power Supply: 24VDC (operational range 12~36V) ensuring robust performance.
Long-Term Stability: ≤0.1%FS per year, guaranteeing consistent accuracy.
Max Range Down: Exceptional 50:1 for flexible measurement ranges.
Max Working Pressure: Flange rated pressure and minimum value of bilateral static pressure for superior reliability.
Ambient Pressure: Operates reliably within -30~70ºC for varied environments.
Medium Temperature: -40~200ºC (dependent on filling liquid) for broad application.
Ex-Proof Grade: Flame proof Exd II CT6 Gb for enhanced safety.
Intrinsic Safety: Exia II CT6 Ga for rigorous safety standards.
Protection Grade: IP67 for robust environmental protection.
Housing Material: Select between Aluminum and 316SS for durability.
Flange Material: 316L, HC (customizable for specific needs).
Diaphragm Material: Options include 316L, HC, Ta, S32205, Ni, Ti, Monel, Inconel, 316L gold plating, and 316L with PTFE coating.
Filing Liquid: Silicon oil with a temperature range of -40~205ºC.
High Temperature Silicon Oil: Operates between -10~300ºC for demanding applications.
Fluorocarbon Oil: Effective within -50~150ºC for specialized uses.
Electrical Interface: Options include 2-M20×1.5(F) or 2-1/2NPT(F) for versatile installation.
Process Connection: Refer to remote diaphragm device selection for tailored solutions.
Selection List
Type | Code | Explanation |
ZY8000Y | ZY8000Y | Intelligent remote transmitter |
Remote system type | A | Pressure (T type)/single flange straight vertical installation |
B | Differential pressure/single flange straight vertical installation |
C | Differential pressure/single flange single flange straight side installation |
D | D/P/high pressure straight side installation, low pressure side remote sealing system |
E | Differential pressure /dual remote sealing system |
Measuring range | 03 | -6~6 |
04 | -40~40 |
05 | -100~100 |
06 | -100~400 |
07 | -100~4000 |
08 | -100~10000 |
Communication protocol | H | HART protocol |
P | PROFIBUS-PA(3.02)Field bus |
F | Communication FF(6.1.1)Field bus communication |
Process connection | o | Splint with 1/4NPT taper piping internal thread |
1 | Freedom flange 1/2NPT taper piping internal thread |
2 | T type thread joint M20×1.5,with rear weldingФ14 impulse pipe ball and cone joint |
3 | 1/4NPTtaper pipe external thread convert to M20×1.5 joint,with rear weldingФ14impulse pipe |
Isolation diaphragm | S | 316L |
C | HC-276 |
M | Monel |
T | Tantalum |
Sensor oil filling | 1 | Silicon oil(-50~205ºC) |
2 | Fluorocarbon oil(-50~150ºC) |
Housing | | Material | Electrical interface |
A | Aluminum | 1/2NPT internal thread,2 electrical joint |
B | Aluminum | M20×1.5 internal thread,2 electrical joint |
C | Stainless steel | 1/2NPT internal thread,2 electrical joint |
D | Stainless steel | M20×1.5 internal thread,2 electrical joint |
Display head | M0 | Without display head |
M5 | LCD display head |
Mounting bracket | | Type | Material |
B0 | Without bracket | |
B2 | B3 bracket | Q235 |
B3 | B3 bracket | 304 |
B4 | L Type bracket | 304 |
Ex-proof | 0 | Non-Explosion-proof |
d | PCEC: Flame-proof Ex dIIC T6 Gb |
i | CLEx:Intrinsic safety Ex iaIIC T6 Ga |
Flange type | FFW | Flush flange seal(2-in/DN50 3-in/DN80 4-in/DN100 RF) |
RFW | Split flange seal(1/2-in/DN15 1-in/DN25 1_1/2-in/DN40 RF) |
EFW | Extend insert flange seal |
FCW | Flush flange seal -RTJ washer surface(2-in/3-in) |
Flange standard | 1 | ANSI/ASME B16.5/HG20615 |
2 | EN1092-1/GOST12815-80/HG20592 |
Flange dimension | | HG20615 | HG20592 |
A | ¾-in | DN10 |
B | 1-in | DN25 |
C | 1½-in | DN40 |
D | 2-in | DN50 |
E | 3-in | DN80 |
F | 4-in | DN100 |
Flange pressure grade | | HG20615 | HG20592 |
2 | 150 psi | PN40 |
4 | 300 psi | PN100 |
6 | 600 psi | N/A |
Flange sealing type | RF | RF surface |
RJ | RJ Ring joint surface |
M | M Male surface |
FM | FM Female surface |
Remote filling liquid | | Sealed liquid | Contact liquid temperature |
E | DC200 Silicon oil | -40ºC~205ºC |
G | DC704 High temperature silicon oil | -10ºC~300ºC |
I | Fluorocarbon oil | -50ºC~150ºC |
Capillary protection coating material | B | 304 Bellows |
C | 316 Bellows |
D | 304 Bellows + PVC Coating |
E | 316 Bellows +PVC Coating |
Capillary length | - | The first and second is the length of H side:00m-15m The third and fourth is the length of L side:00m-15m |
Flange material | A | CS |
B | 304 |
C | 316 |
D | 316L |
H side diaphragm insert cylinder length | - | H0=0mm(Flush flange selection) H1=50mm H2=100mm H3=150mm H4=200mm H5=250mm HX: customized dimension |
L side diaphragm insert cylinder length | - | L0=0mm(Flush flange selection) L1=50mm L2=100mm L3=150mm L4=200mm L5=250mm LX: customized dimension |
Flange isolation diaphragm material | S | 316L |
C | HC-276 |
M | Monel |
T | Tantalum |
V | 316 Gold plating |
P | 316L+PTFE |
Insert cylinder | 0 | Without insert cylinder |
1 | 316L |
2 | HC-276 |
3 | Monel |
Additional option | / | Refer to additional selection list (as follow) |
Project | Code | Explanation |
Additional accreditation | P10 | SIL |
Flushing ring | | Thread | Material |
G30X | 1/4 NPT+Plug | X:1 means 1 flush hole 2 means 2 flush hole | 304 |
G31X | 1/4 NPT+ Plug | 316 |
G32X | 1/2 NPT+ Plug | 304 |
G33X | 1/2 NPT+ Plug | 316 |
Electrical joint | | Specification and Dimension | Material |
G60 | M20×1.5 Electrical joint + one plug | PA |
G61 | 1/2NPT Electrical joint + one plug | PA |
G70 | M20×1.5 Ex-proof Electrical joint+1 plug | 304 |
G71 | 1/2NPT Ex-proof Electrical joint+1 plug | 304 |
Measuring Range
Range code | GP Gauge pressure (Kpa ) |
Measuring range | Overload limit | Rated pressure(Max) |
03 | -6~6 | 2000 | Flange rated pressure and the minimum value of the upper limit of the measuring range |
04 | -40~40 | 5000 |
05 | -100~100 | 7000 |
06 | -100~400 | 10000 |
07 | -100~4000 | 10000 |
08 | -100~10000 | 10000 |
Range code | DP Differential pressure (Kpa) |
Range | Measuring range | Unilateral overpressure | Bilateral static pressure | Rated pressure (Max) |
03 | 6 | -6~6 | 2000 | 16000 | The lower value of remote flange rated pressure and bilateral static |
04 | 40 | -40~40 | 5000 | 25000 |
05 | 100 | -100~100 | 7000 | 25000 |
06 | 400 | -400~400 | 10000 | 25000 |
07 | 4000 | -500~4000 | 10000 | 25000 |
08 | 10000 | -500~10000 | 10000 | 25000 |
Selection List
Type | Code | Explanation |
ZY8000Y | ZY8000Y | Intelligent remote transmitter |
Remote system type | A | Pressure (T type)/single flange straight vertical installation |
B | Differential pressure/single flange straight vertical installation |
C | Differential pressure/single flange single flange straight side installation |
D | D/P/high pressure straight side installation, low pressure side remote sealing system |
E | Differential pressure /dual remote sealing system |
Measuring range | 03 | -6~6 |
04 | -40~40 |
05 | -100~100 |
06 | -100~400 |
07 | -100~4000 |
08 | -100~10000 |
Communication protocol | H | HART protocol |
P | PROFIBUS-PA(3.02)Field bus |
F | Communication FF(6.1.1)Field bus communication |
Process connection | o | Splint with 1/4NPT taper piping internal thread |
1 | Freedom flange 1/2NPT taper piping internal thread |
2 | T type thread joint M20×1.5,with rear weldingФ14 impulse pipe ball and cone joint |
3 | 1/4NPTtaper pipe external thread convert to M20×1.5 joint,with rear weldingФ14impulse pipe |
Isolation diaphragm | S | 316L |
C | HC-276 |
M | Monel |
T | Tantalum |
Sensor oil filling | 1 | Silicon oil(-50~205ºC) |
2 | Fluorocarbon oil(-50~150ºC) |
Housing | | Material | Electrical interface |
A | Aluminum | 1/2NPT internal thread,2 electrical joint |
B | Aluminum | M20×1.5 internal thread,2 electrical joint |
C | Stainless steel | 1/2NPT internal thread,2 electrical joint |
D | Stainless steel | M20×1.5 internal thread,2 electrical joint |
Display head | M0 | Without display head |
M5 | LCD display head |
Mounting bracket | | Type | Material |
B0 | Without bracket | |
B2 | B3 bracket | Q235 |
B3 | B3 bracket | 304 |
B4 | L Type bracket | 304 |
Ex-proof | 0 | Non-Explosion-proof |
d | PCEC: Flame-proof Ex dIIC T6 Gb |
i | CLEx:Intrinsic safety Ex iaIIC T6 Ga |
Flange type | FFW | Flush flange seal(2-in/DN50 3-in/DN80 4-in/DN100 RF) |
RFW | Split flange seal(1/2-in/DN15 1-in/DN25 1_1/2-in/DN40 RF) |
EFW | Extend insert flange seal |
FCW | Flush flange seal -RTJ washer surface(2-in/3-in) |
Flange standard | 1 | ANSI/ASME B16.5/HG20615 |
2 | EN1092-1/GOST12815-80/HG20592 |
Flange dimension | | HG20615 | HG20592 |
A | ¾-in | DN10 |
B | 1-in | DN25 |
C | 1½-in | DN40 |
D | 2-in | DN50 |
E | 3-in | DN80 |
F | 4-in | DN100 |
Flange pressure grade | | HG20615 | HG20592 |
2 | 150 psi | PN40 |
4 | 300 psi | PN100 |
6 | 600 psi | N/A |
Flange sealing type | RF | RF surface |
RJ | RJ Ring joint surface |
M | M Male surface |
FM | FM Female surface |
Remote filling liquid | | Sealed liquid | Contact liquid temperature |
E | DC200 Silicon oil | -40ºC~205ºC |
G | DC704 High temperature silicon oil | -10ºC~300ºC |
I | Fluorocarbon oil | -50ºC~150ºC |
Capillary protection coating material | B | 304 Bellows |
C | 316 Bellows |
D | 304 Bellows + PVC Coating |
E | 316 Bellows +PVC Coating |
Capillary length | - | The first and second is the length of H side:00m-15m The third and fourth is the length of L side:00m-15m |
Flange material | A | CS |
B | 304 |
C | 316 |
D | 316L |
H side diaphragm insert cylinder length | - | H0=0mm(Flush flange selection) H1=50mm H2=100mm H3=150mm H4=200mm H5=250mm HX: customized dimension |
L side diaphragm insert cylinder length | - | L0=0mm(Flush flange selection) L1=50mm L2=100mm L3=150mm L4=200mm L5=250mm LX: customized dimension |
Flange isolation diaphragm material | S | 316L |
C | HC-276 |
M | Monel |
T | Tantalum |
V | 316 Gold plating |
P | 316L+PTFE |
Insert cylinder | 0 | Without insert cylinder |
1 | 316L |
2 | HC-276 |
3 | Monel |
Additional option | / | Refer to additional selection list (as follow) |
Project | Code | Explanation |
Additional accreditation | P10 | SIL |
Flushing ring | | Thread | Material |
G30X | 1/4 NPT+Plug | X:1 means 1 flush hole 2 means 2 flush hole | 304 |
G31X | 1/4 NPT+ Plug | 316 |
G32X | 1/2 NPT+ Plug | 304 |
G33X | 1/2 NPT+ Plug | 316 |
Electrical joint | | Specification and Dimension | Material |
G60 | M20×1.5 Electrical joint + one plug | PA |
G61 | 1/2NPT Electrical joint + one plug | PA |
G70 | M20×1.5 Ex-proof Electrical joint+1 plug | 304 |
G71 | 1/2NPT Ex-proof Electrical joint+1 plug | 304 |
Shandong Zhongziyi Intelligent Technology Co., Ltd. seamlessly integrates the world's most advanced design philosophies and cutting-edge process technologies. It is our mission to provide top-tier products that embody reliability and excellence.
Our product features the world's leading mono-crystalline silicon sensor, a highly reliable electronic module design, and an advanced precision temperature and linear correction system.
These are combined with intelligent manufacturing technology to ensure unparalleled precision, exceptional stability, and remarkable consistency in performance.
Our product stands as a testament to our commitment to quality.
Boasting complete intelligent diagnostics, simulation capabilities, monitoring, local configuration, and versatile communication functions, our product meets the most stringent electromagnetic compatibility and lightning protection standards. It is broadly applied in sectors such as electric power, metallurgy, chemical industry, coal chemical industry, petroleum, petrochemical,environmental protection, food processing, medicine, building materials, light industry, nuclear industry, and many more.
The diagnostic function can also be activated through HART, FF, PA, and other communication protocols. Alarms are communicated via warning or fault protection current. This system automatically diagnoses the operational status of the SENSOR, ROM, RAM, EEPROM, and software. In the event of electronic unit or measuring element failure, the faulty component can be swiftly replaced on-site without requiring recalibration.
Shandong Zhongziyi Intelligent Technology Co., Ltd.Located in Zibo Science and Technology Industrial Park, our company occupies an expansive area of more than 18,000.00 square meters. We proudly boast a state-of-the-art manufacturing facility, built to the highest standards and equipped with modern amenities.We are committed tothe research and development (R&D),manufacturing,sales, and service of high-quality pressure and temperature instruments.
As a standing director unit of the National Pressure Gauge Industry Association, we have earned the ISO9001 Quality Management System certification. We are also recognized as a high-tech enterprise in Shandong Province.
We are proud to be a close partner of Rosemount in China, constantly aligning our technology advancements with theirs.
Our factory has been deeply engaged in the R&D and production of instruments for almost 60 years, accumulating extensive technological expertise and customer service experience. Our products are widely used in Petroleum, Chemical, Papermaking,Metallurgy,Medicine,Food,Power, and Machinery industries. Our sales network covers the entire country and extends abroad, earning trust and favorable comments from a broad base of users.
The company's core values are "Quality First, Customer First."
We warmly welcome customers to visit our factory and discuss potential cooperation.
Our Company and Factory
Packaging & Shipping
We will deliver your ordered products at the earliest possible date, as per your requirements.
We trust that the best team wins!
Exhibition Pictures
We are actively seeking international cooperation through global exhibitions.
FAQ
1. What kind of product do you supply?
O
ur product range
includes:
pressure transmitters, temperature transmitters, level transmitters, pressure gauges, temperature gauges, and flow
meters.
2. What are your product and technology advantages?
Our factory was established in 1966, boasting nearly 60 years of manufacturing and R&D experience. We are also a super-close partner of Rosemount in
China.
Our technology closely
follows Rosemount's. Notably, our remote pressure transmitter technology and stability are ranked No. 1 in China.
3. Where is your factory located?
O
ur factory is located in Zibo, Shandong province, China, one of the top
three
instrument production areas.
A
nd it spans more than 18,000 square meters.
4. Can we visit your factory?
Y
ou are always welcome to visit our factory at your convenience.
5. What is the warranty on your products?
O
ur product warranty is 12 months from the shipping date, and we offer
lifetime
maintenance.
6. What are your payment terms?
Currently,
we accept a 50% down payment and 50% balance payable 5 days before delivery via T/T, Western Union,
PayPal,
and trade assurance online payment.
7. What certifications do you have?
W
e hold ISO9001, CCC, CNAS laboratory accreditation, Flame-proof certification, intrinsic safety certification, SIL certificate, ECM certificate, Russia EAC and PAC certificates,
a
nd
several
invention patents.
8. What is your delivery time?
F
or peak seasons, it's 4 weeks, and for the off-season, it's 2 weeks. Regardless of the season, we will strive to meet your requirements.
9. How is your after-sales service?
Our products enjoy a strong reputation for excellent quality, with almost no warranty issues arising from the products themselves. Nevertheless, we provide 24/7 online
support for installation, commissioning, operation, or any other issues.
10. How can I send a quotation?
Y
ou can send your quotation to us via email or cellphone as follows:
Address:
No. 8 Sanying Road, Zibo Science and Technology Industrial Park, Fangzhen Town, Zhangdian District, Zibo City, Shandong Province
Business Type:
Manufacturer/Factory
Business Range:
Instruments & Meters
Company Introduction:
Different kinds of products are available in our company. We′re pleased to get your Inquiry and we will reply you as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.